Requirements at a glance
| Agency | Board of State Examiners of Electricians (Division of Occupational Licensure); exams by PSI |
|---|---|
| License | Journeyman Electrician |
| Format | Part 1: 80 questions, 180 minutes, open book, 70% to pass |
| Exams | Part 1 (80 questions, 180 minutes), then Part 2 Applied (30 questions, 60 minutes) |
| Fees | $80 to PSI for Part 1 and $55 for Part 2, plus the Board application and license fee |
Electrical apprentices applying for a Massachusetts journeyman electrician license from the Board of State Examiners of Electricians.
Official links
How to get licensed, step by step
Apply to the Board
Apply through the Board with your education and work hours, a CORI authorization and a 15-hour code update certificate. Review takes up to 30 days. Approval lasts 12 months.
Board of State Examiners of Electricians (opens in a new tab)
Schedule the journeyman electrician exam with PSI
PSI emails an exam confirmation notice after approval. Test at a PSI site in Auburn, Boston, Fall River, Lawrence or West Springfield. Cancel at least 2 days ahead.
Schedule with PSI (Massachusetts electricians) (opens in a new tab)
Pass both parts
Each part is scored separately at 70%. If you fail one, retake only that part, up to 6 times within a year of approval.
Schedule with PSI (Massachusetts electricians) (opens in a new tab)
Get licensed
Your scores go to the Division of Occupational Licensure. Pay the license fee in the eLIPSE portal to get your license.
Board of State Examiners of Electricians (opens in a new tab)
How to prepare
- Massachusetts adopted the 2026 NEC with state amendments (527 CMR 12.00) effective 4/24/2026. The PSI bulletin names no NEC year and adds code items about seven months after adoption, so check the bulletin for your test date.
- Bring the NEC, the Massachusetts amendments and NFPA 72. Highlighting, underlining and margin notes are allowed before the exam; only a silent, non-programmable calculator is allowed.
- Wiring methods and devices (18) and services (11) are over a third of Part 1: tab Chapter 3 and Articles 230, 250 and 310.
- Alarm systems (6), solar (6) and battery storage (4) are 16 of 80 questions: know NFPA 72 basics and NEC Articles 690, 705 and 706.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), edition adopted by the BoardEssential
Allowed in the exam room. Massachusetts adopted the 2026 edition with state amendments effective 4/24/2026; confirm the tested edition in your PSI bulletin.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
NFPA 72: National Fire Alarm and Signaling Code
Allowed in the exam room. Alarm systems are 6 questions on each electrician Part 1, and it is the core reference for the systems exams.
237 CMR: Rules and Regulations of the Board of State Examiners of Electricians
Allowed in the exam room. Source of the licensing and state-specific questions.
Massachusetts regulations (Cornell LII, free to read) (opens in a new tab)
Official reference list (as published by the testing agency)
- National Electrical Code (NFPA 70), the edition adopted by the Board
- 527 CMR 12.00: Massachusetts amendments to the NEC
- NFPA 72 National Fire Alarm and Signaling Code
- Ugly's Electrical References and American Electricians' Handbook (listed by PSI as sources, not allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 8 | |
| Services | 11 | |
| Grounding and Bonding | 7 | |
| Wiring Methods and Devices | 18 | |
| Motors | 4 | |
| Transformers | 1 | |
| Low-Voltage Distribution | 2 | |
| Special Occupancies and Equipment | 5 | |
| Overcurrent Protection | 6 | |
| Lighting | 2 | |
| Alarm Systems | 6 | |
| Solar | 6 | |
| Battery Storage | 4 |
Exam day details
- Administered by PSI Services for the Massachusetts Board of State Examiners of Electricians.
- Fee: $80 to PSI for Part 1 and $55 for Part 2. Board application and license fees are separate.
- 80 questions in 180 minutes; 70% (56) to pass. Part 2 for journeymen is the Applied exam (30 questions in 60 minutes), which is not part of this practice bank.
- Open book and two parts. Each part is scored on its own and you must pass both. Journeyman Part 2 is the Applied exam; Master Part 2 is Business and Law.
- If you fail a part, you can retake just that part up to 6 times within 1 year of your application approval date. Application approval lasts 12 months. Under 237 CMR 14.02 (amended 11/21/2025), after 3 failed attempts the Board requires proof of a Board-approved exam review or prep course, and after 6 you must repeat the required education hours.
- Allowed in the exam room: the adopted NEC, the Massachusetts amendments (527 CMR 12.00), NFPA 72, the Board's rules (237 CMR) and the listed Massachusetts laws. Highlighting and underlining are allowed, and so are handwritten notes in the margins before the exam; only a silent, non-programmable calculator is allowed.
- Exams are scheduled daily at PSI sites in Auburn, Boston, Fall River, Lawrence and West Springfield. Cancel at least 2 days ahead or you forfeit the fee.
- The Board approves your application first (high school diploma, 600 hours of journeyman education, 4 years and 8,000 hours of work, a CORI check and a 15-hour code update certificate; masters need a 150-hour master course and 1 year as a Massachusetts journeyman). Applications take up to 30 days.
Note: 527 CMR 12.00 adopted the 2026 NEC with Massachusetts amendments, effective 4/24/2026. The PSI bulletin (effective 9/30/2026) names no NEC year, but says new code items can be added seven months after a code takes effect, which is about late November 2026. Our questions follow the 2026 NEC; check your PSI bulletin for the edition on your test date.
Frequently asked questions
What is on the Massachusetts journeyman electrician Part 1 exam?
80 questions: wiring methods and devices 18, services 11, general knowledge 8, grounding and bonding 7, overcurrent protection 6, alarm systems 6, solar 6, special occupancies and equipment 5, motors 4, battery storage 4, low-voltage distribution 2, lighting 2 and transformers 1.
Which NEC edition is on the Massachusetts exam?
Massachusetts adopted the 2026 NEC with state amendments effective 4/24/2026. The PSI bulletin names no year, and new code items can be added seven months after adoption, so check the bulletin for your test date.
Is the exam open book?
Yes. Bring the NEC, the Massachusetts amendments and NFPA 72. You can highlight, underline and write margin notes beforehand, but only on PSI's scrap paper during the exam.
Free questions with answers
Show all 10 free questions and answers
After rapid shutdown is initiated on a commercial rooftop PV system, controlled conductors located outside the array boundary (or more than 3 ft inside a building from where they enter) must be limited to what value?
Answer: 30 volts or less within 30 seconds
690.12(B)(1) limits controlled conductors outside the array boundary, or more than 1 m (3 ft) inside a building from the point of entry, to 30 volts within 30 seconds of initiation. The 80-volt figure applies to conductors inside the array boundary.
Reference: 2026 National Electrical Code (NFPA 70), 690.12(B)(1)
Under the 2026 NEC, what is required of an energy storage system installed in a building?
Answer: It must be listed
706.2 requires energy storage systems to be listed (see UL 9540). Outdoor placement, utility approval of field-built assemblies and a 48-volt minimum are not requirements of Article 706. A separate nameplate rule is in 706.4.
Reference: 2026 National Electrical Code (NFPA 70), 706.2
A fire alarm control panel is being connected to a 120-volt branch circuit in a new office building. Which statement about that branch circuit is correct?
Answer: It may supply no other loads besides the fire alarm equipment
760.41(B) for non-power-limited systems and 760.121(B)(1) for power-limited systems require the branch circuit supplying fire alarm equipment to supply no other loads. Sharing the circuit would let an unrelated overload or switching action take the alarm system out of service.
Reference: 2026 National Electrical Code (NFPA 70), 760.41(B); 760.121(B)(1)
Overhead 120/240-volt service conductors cross a residential driveway. Using 230.24(B), what is the minimum clearance from final grade?
Answer: 12 ft
230.24(B) requires 12 ft over residential property and driveways, and over commercial areas not subject to truck traffic, where the voltage does not exceed 300 volts to ground. 10 ft applies at the point of attachment of a drip loop for 150 volts or less to ground, 15 ft is for voltages above 300 volts to ground, and 18 ft is for public streets, alleys and roads.
Reference: 2026 National Electrical Code (NFPA 70), 230.24(B)
An electrician adds two circuits to an existing Massachusetts building whose older wiring does not meet the current code. What does Rule 3 of 527 CMR 12.00 require?
Answer: The addition must comply with the Code, without upgrading the rest, and must not worsen an existing violation
Rule 3 says additions or modifications to an existing installation shall be made in accordance with the Code without bringing the remaining part of the installation into compliance. The installation shall not create a violation of the Code, nor increase the magnitude of an existing violation.
Reference: 527 CMR 12.00 (2026 Massachusetts amendments to the NEC), Rule 3 (Massachusetts)
In Massachusetts, a 10 AWG solid conductor is to be terminated under the wire-binding screw of a receptacle. Under 110.14(A) as amended by 527 CMR 12.00, which statement is correct?
Answer: Wire-binding screws are permitted for 10 AWG or smaller solid conductors or Class B stranded conductors
The Massachusetts amendment replaces the last sentence of the first paragraph of 110.14(A): connection by wire-binding screws or studs and nuts with upturned lugs or equivalent is permitted for 10 AWG or smaller solid conductors, or conductors with Class B stranding. Class C stranded conductors terminated (not looped) on such terminals must have the strands enclosed in the termination or made solid.
Reference: 527 CMR 12.00 (2026 Massachusetts amendments to the NEC), 110.14(A) (Massachusetts)
A footing contains 25 ft of 1/2-in. rebar with 3 in. of concrete cover, but the concrete was poured over a plastic vapor barrier that separates it from the soil. May the rebar serve as the concrete-encased electrode under 250.52(A)(3)?
Answer: No; the vapor barrier means the concrete is not in direct contact with the earth
250.52(A)(3) requires at least 20 ft of 1/2-in. rebar, or 20 ft of bare 4 AWG copper, encased in at least 2 in. of concrete in a foundation or footing in direct contact with the earth. The informational note says concrete separated from the earth by insulation, vapor barriers or films is not in direct contact. The size and cover are fine, but the barrier disqualifies it.
Reference: 2026 National Electrical Code (NFPA 70), 250.52(A)(3)
A 15 hp, 230-volt, three-phase continuous-duty motor has a full-load current of 42 A in Table 430.250. Under 430.22, what is the minimum ampacity of the branch-circuit conductors?
Answer: 52.5 A
430.22 requires branch-circuit conductors for a single continuous-duty motor to have an ampacity of at least 125 percent of the motor full-load current from the table: 42 x 1.25 = 52.5 A. 42 A uses 100 percent, 48.3 A is the 115 percent disconnect figure, and 63 A is 150 percent.
Reference: 2026 National Electrical Code (NFPA 70), 430.22; Table 430.250
During an inspection a branch-circuit molded-case breaker shows no interrupting rating marked anywhere. What interrupting rating does 240.83(C) mean it has?
Answer: 5,000 A
240.83(C) requires every circuit breaker with an interrupting rating other than 5,000 A to show that rating on the breaker, so an unmarked breaker is a 5,000-ampere device. 10,000 A is a common marked rating, which is why it is a common wrong answer.
Reference: 2026 National Electrical Code (NFPA 70), 240.83(C)
Under Massachusetts 517.26, how does Article 700 apply to a health care facility's essential electrical system?
Answer: Article 700 does not apply, except that the life safety branch must comply with 700.10(D)
527 CMR 12.00 revises 517.26: (A) other than as specified in (B), the requirements of Article 700 shall not apply; (B) the life safety branch of the essential electrical system shall comply with 700.10(D).
Reference: 527 CMR 12.00 (2026 Massachusetts amendments to the NEC), 517.26 (Massachusetts)