Requirements at a glance
| Agency | Board of State Examiners of Plumbers and Gas Fitters (Division of Occupational Licensure); exams by PSI |
|---|---|
| License | Master Plumber |
| Format | Part 1: 80 questions, 160 minutes, closed book, 70% to pass |
| Fees | $80 PSI exam fee; the license fee in eLIPSE is $52 (journeyman, gas fitter, LP gas installer), $78 (master plumber) or $97 (master gas fitter) |
Journeyman plumbers applying for a Massachusetts master plumber license from the Board of State Examiners of Plumbers and Gas Fitters.
Official links
How to get licensed, step by step
Apply to the Board
Apply online through eLIPSE with your apprenticeship hours and education. The Board approves you, then PSI contacts you to schedule.
Board of State Examiners of Plumbers and Gas Fitters (opens in a new tab)
Schedule the master plumber exam with PSI
Test at a PSI site in Auburn, Boston, Fall River, Lawrence or West Springfield. Cancel at least 2 days ahead or you forfeit the fee.
Schedule with PSI (Massachusetts plumbers and gas fitters) (opens in a new tab)
Pass both parts
Each part is scored separately at 70%. Retake within 12 months of approval; after six failed attempts you must petition the Board in writing.
Schedule with PSI (Massachusetts plumbers and gas fitters) (opens in a new tab)
Get licensed
Pay the license fee in eLIPSE after you pass both parts.
Board of State Examiners of Plumbers and Gas Fitters (opens in a new tab)
How to prepare
- Both parts are closed book. Nothing is allowed in the room, so learn the code rules and numbers rather than where to find them.
- The editions are 248 CMR 3.00, 4.00, 5.00 and 11.00 (2021), 10.00 (2023 plumbing code), NFPA 54 (2012) and NFPA 58 (2011).
- The outline matches the journeyman exam: gas piping (21), drain, waste and vent (13) and venting (12) are 46 of 80 questions.
- Part 2 is the shared plumber Part 2 exam (isometrics 20, trade calculations 5, gas piping 7, gas venting 8).
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
248 CMR 3.00 to 11.00: Massachusetts plumbing and gas rulesEssential
Not allowed in the exam room (closed book). The core of both plumbing and gas exams: Uniform State Plumbing Code (10.00, 2023), Fuel Gas Code (4.00 and 5.00, 2021), 6.00, 7.00 and 11.00.
Massachusetts regulations (Cornell LII, free to read) (opens in a new tab)
MGL Chapter 142: Supervision of Plumbing
Not allowed in the exam room. Licensing, permits and the water heater rules.
Massachusetts General Laws (free to read) (opens in a new tab)
Official reference list (as published by the testing agency)
- 248 CMR 3.00 (2021), 4.00 (2021), 5.00 (2021), 6.00 (2014 amendments to NFPA 58), 7.00 (2014) and 11.00 (2021)
- 248 CMR 10.00 to 10.23: Massachusetts Uniform State Plumbing Code (2023)
- NFPA 54 National Fuel Gas Code (2012) and NFPA 58 Liquefied Petroleum Gas Code (2011)
- MGL Chapter 142: Supervision of Plumbing, and the general provisions governing plumbing and gas work
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Regulations, Inspections, and Permits | 9 | |
| Gas Piping, Equipment, and Appliances | 21 | |
| Venting | 12 | |
| Traps and Cleanouts | 2 | |
| Fixtures, Equipment, and Clearances | 2 | |
| Water Heaters | 3 | |
| Piping, Valves, and Controls | 3 | |
| Water Supply | 6 | |
| Hangers and Supports | 2 | |
| Drain, Waste, and Vent | 13 | |
| Separators, Interceptors, and Grease Traps | 5 | |
| Joints and Connections | 2 |
Exam day details
- Administered by PSI Services for the Massachusetts Board of State Examiners of Plumbers and Gas Fitters.
- Fee: $80 PSI exam fee (retakes pay again, non-refundable). Board application and the license fee ($78 for master plumber) are separate.
- 80 questions in 160 minutes; 70% to pass. The outline matches the journeyman exam. Part 2 is the plumber Part 2 exam (40 questions), which Journeyman and Master Plumber applicants both take; it has its own practice exam.
- Closed book and two parts. Each part is scored on its own and you must pass both. Nothing is allowed in the exam room, and a silent non-programmable calculator is the only aid.
- If you fail, retake within 12 months of your application approval date. After six failed attempts you must petition the Board in writing before more attempts.
- The references are 248 CMR 3.00, 4.00, 5.00 and 11.00 (2021), 6.00 (2014 NFPA 58 amendments), 7.00 (2014 large gas equipment), 10.00 (Uniform State Plumbing Code, 2023), NFPA 54 (2012), NFPA 58 (2011), and MGL c.142.
- Apply to the Board through the eLIPSE portal. After you pass both parts, pay the license fee in eLIPSE. Exams are at PSI sites in Auburn, Boston, Fall River, Lawrence and West Springfield.
Frequently asked questions
What is on the Massachusetts master plumber exam?
Part 1 has 80 questions: gas piping, equipment and appliances 21, drain, waste and vent 13, venting 12, general regulations, inspections and permits 9, water supply 6, separators, interceptors and grease traps 5, water heaters 3, piping, valves and controls 3, and smaller sections for traps, fixtures, hangers and joints.
Is it open book?
No. Both parts are closed book.
Is Part 2 different from the journeyman Part 2?
No. The PSI bulletin lists one plumber Part 2 (40 questions) for both journeyman and master applicants.
Free questions with answers
Show all 10 free questions and answers
A master plumber wants Board permission to use a non-code piping system. She expects to use it on many jobs at different sites and needs to prove its feasibility first. Which Board mechanism under 248 CMR 3.04 fits, and why?
Answer: A Test-site, because it is appropriate when the alternative may be used for more than one installation at more than one location
A Variance covers one instance at one location (unusual circumstance or hardship). A Test-site is for an alternative method, material, system or technology likely to be used in multiple installations and locations. Work cannot begin until the Board votes to grant it, and the request is made before the permit application.
Reference: 248 CMR 3.00 (eff. 4/30/2021), 248 CMR 3.04(2)(a) and 3.04(4)(b)
A master plumber plans a new gas piping system rated at 6,500,000 Btu/hr. Before the Inspector will issue the permit, what must be submitted with the engineer-stamped drawings under 248 CMR 5.05(1)?
Answer: A written statement from the serving gas supplier that it can deliver the required volume, pressure and demand
Systems over 5,000,000 Btu/hr must be designed by a Massachusetts registered professional engineer. The installer gives the Inspector the stamped drawings and a written statement from the serving gas supplier that it can provide the volume, pressure and maximum gas demand needed, including for existing systems. This replaces NFPA 54 5.1.1.
Reference: 248 CMR 5.00 (NFPA 54 amendments), 248 CMR 5.05(1)(a)
A through-the-wall gas vent terminates 7.5 feet above finished grade on a residence. Under 248 CMR 5.12(6), is the 'GAS VENT DIRECTLY BELOW' identification plate required?
Answer: No; it is required only when the terminal is under seven feet above finished grade
Section 12.9.7 applies whenever a through-the-wall vent is installed less than seven feet above finished grade. Then a metal or plastic plate is mounted outside, at least eight feet above grade in line with the terminal, with lettering not smaller than 0.5 inch. At 7.5 feet the plate is not required.
Reference: 248 CMR 5.00 (NFPA 54 amendments), 248 CMR 5.12(6) (NFPA 54 12.9.7)
Two back-to-back fixtures (other than water closets) are served by one fitting on a vertical drain. Which fitting does 248 CMR 10.15(8)(b) require?
Answer: A double sanitary drainage pattern tee
Back-to-back fixtures on a vertical drain use a double sanitary drainage pattern tee; on horizontal piping only double sanitary wyes are allowed, to eliminate throw-over. The exception lets water closets use double wyes if the toilet manufacturer's instructions require it.
Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.15(8)(b)
A combination sink and wash tray has compartments whose waste outlets are 26 inches apart, and one compartment is 5 inches deeper than the other. Under 248 CMR 10.08(2)(a)1, how may it be trapped?
Answer: On one trap, since the depth difference is under six inches and outlets are under 30 inches apart
A combination fixture may use one trap if one compartment is not more than six inches deeper than the other and the waste outlets are not more than 30 inches apart. Here the 5 inch difference and 26 inch spacing both meet the limits. Otherwise each fixture needs its own trap set as close to the outlet as possible.
Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.08(2)(a)1.a.ii
A master plumber sets the tempering valves for lavatories in an office building's public restrooms and in a single-family home. Under 248 CMR 10.10(10)(a) and (b), what are the maximum hot water temperatures at these lavatories?
Answer: 120 degrees F for public and employee; 130 degrees F for residential
Public and employee lavatories are limited to 120 degrees F hot water (and faucets to 0.5 GPM); residential lavatories are limited to 130 degrees F, which matches the residential limit in 248 CMR 10.14(5)(c).
Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.10(10)(a) and (b)
A grease interceptor is installed outside a building as required by another agency. What chamber vent does 248 CMR 10.09(1)(b)12 require?
Answer: A vent of at least 4 inches, piped to the inside of the building under 10.16
An outside grease interceptor or trap needs a chamber vent of at least four inches in diameter, piped to the inside of the building in compliance with 248 CMR 10.16; it may connect into the building's sanitary venting system.
Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.09(1)(b)12.b
How must the discharge from a temperature and pressure relief valve on a water heater be piped under 248 CMR 10.14(6)(f)2.c?
Answer: Full size, non-ferrous or rated tubing, no shutoff, ending within 12 inches of the floor
The T&P valve discharge outlet must be full size and piped in non-ferrous material or tubing rated to withstand the maximum relief valve temperature, with no shutoff, to a fixture or to a point within twelve inches of the floor.
Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.14(6)(f)2.c
A building water system has solenoid valves and quick-closing valves. What does 248 CMR 10.14(2)(b) require?
Answer: Rechargeable air chambers or product-accepted mechanical devices, near the valves and accessible
Systems with quick-acting or solenoid valves need devices to absorb the pressure surge: air chambers provided with a means to restore air if waterlogged, or other Product-accepted mechanical devices, placed as close as possible to the valves and accessible for maintenance or replacement.
Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.14(2)(b)
A pressure reducing valve is installed to cut the building water pressure to 80 psig. What else must be installed under 248 CMR 10.14(2)(e)?
Answer: A gauge of at least 0-150 psig range within 24 inches downstream of the valve
Where pressure exceeds 80 psig at any fixture, device or appurtenance, a pressure reducing valve limits it to 80 psig upstream of the device, and a gauge with a minimum range of 0-150 psig is installed within 24 inches downstream of the valve. Piping upstream and downstream of a booster is exempt.
Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.14(2)(e)
Sources
- PSI: Massachusetts Plumbers and Gas Fitters Candidate Information Bulletin (10/3/2025) (opens in a new tab)
- Massachusetts Board of State Examiners of Plumbers and Gas Fitters (opens in a new tab)
- 248 CMR (Plumbers and Gas Fitters), Cornell LII (opens in a new tab)
Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.