Massachusetts licensing exam

Massachusetts Master Plumber Exam (Part 1, Written): Practice Test & Licensing Guide

Part 1 of the Massachusetts master plumber exam: 80 questions in 160 minutes on gas piping, venting, drain, waste and vent, water supply and the plumbing and gas rules in 248 CMR. Closed book, 70% to pass.

Questions
80
Time limit
2.6666666666666665 hours
Passing score
70%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Regulations, Inspections, and Permits

A master plumber wants Board permission to use a non-code piping system. She expects to use it on many jobs at different sites and needs to prove its feasibility first. Which Board mechanism under 248 CMR 3.04 fits, and why?

Requirements at a glance

AgencyBoard of State Examiners of Plumbers and Gas Fitters (Division of Occupational Licensure); exams by PSI
LicenseMaster Plumber
FormatPart 1: 80 questions, 160 minutes, closed book, 70% to pass
Fees$80 PSI exam fee; the license fee in eLIPSE is $52 (journeyman, gas fitter, LP gas installer), $78 (master plumber) or $97 (master gas fitter)

Journeyman plumbers applying for a Massachusetts master plumber license from the Board of State Examiners of Plumbers and Gas Fitters.

How to get licensed, step by step

  1. Apply to the Board

    Apply online through eLIPSE with your apprenticeship hours and education. The Board approves you, then PSI contacts you to schedule.

    Board of State Examiners of Plumbers and Gas Fitters (opens in a new tab)

  2. Schedule the master plumber exam with PSI

    Test at a PSI site in Auburn, Boston, Fall River, Lawrence or West Springfield. Cancel at least 2 days ahead or you forfeit the fee.

    Schedule with PSI (Massachusetts plumbers and gas fitters) (opens in a new tab)

  3. Pass both parts

    Each part is scored separately at 70%. Retake within 12 months of approval; after six failed attempts you must petition the Board in writing.

    Schedule with PSI (Massachusetts plumbers and gas fitters) (opens in a new tab)

  4. Get licensed

    Pay the license fee in eLIPSE after you pass both parts.

    Board of State Examiners of Plumbers and Gas Fitters (opens in a new tab)

How to prepare

  • Both parts are closed book. Nothing is allowed in the room, so learn the code rules and numbers rather than where to find them.
  • The editions are 248 CMR 3.00, 4.00, 5.00 and 11.00 (2021), 10.00 (2023 plumbing code), NFPA 54 (2012) and NFPA 58 (2011).
  • The outline matches the journeyman exam: gas piping (21), drain, waste and vent (13) and venting (12) are 46 of 80 questions.
  • Part 2 is the shared plumber Part 2 exam (isometrics 20, trade calculations 5, gas piping 7, gas venting 8).
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

Official reference list (as published by the testing agency)
  • 248 CMR 3.00 (2021), 4.00 (2021), 5.00 (2021), 6.00 (2014 amendments to NFPA 58), 7.00 (2014) and 11.00 (2021)
  • 248 CMR 10.00 to 10.23: Massachusetts Uniform State Plumbing Code (2023)
  • NFPA 54 National Fuel Gas Code (2012) and NFPA 58 Liquefied Petroleum Gas Code (2011)
  • MGL Chapter 142: Supervision of Plumbing, and the general provisions governing plumbing and gas work

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Regulations, Inspections, and Permits9
Gas Piping, Equipment, and Appliances21
Venting12
Traps and Cleanouts2
Fixtures, Equipment, and Clearances2
Water Heaters3
Piping, Valves, and Controls3
Water Supply6
Hangers and Supports2
Drain, Waste, and Vent13
Separators, Interceptors, and Grease Traps5
Joints and Connections2

Exam day details

  • Administered by PSI Services for the Massachusetts Board of State Examiners of Plumbers and Gas Fitters.
  • Fee: $80 PSI exam fee (retakes pay again, non-refundable). Board application and the license fee ($78 for master plumber) are separate.
  • 80 questions in 160 minutes; 70% to pass. The outline matches the journeyman exam. Part 2 is the plumber Part 2 exam (40 questions), which Journeyman and Master Plumber applicants both take; it has its own practice exam.
  • Closed book and two parts. Each part is scored on its own and you must pass both. Nothing is allowed in the exam room, and a silent non-programmable calculator is the only aid.
  • If you fail, retake within 12 months of your application approval date. After six failed attempts you must petition the Board in writing before more attempts.
  • The references are 248 CMR 3.00, 4.00, 5.00 and 11.00 (2021), 6.00 (2014 NFPA 58 amendments), 7.00 (2014 large gas equipment), 10.00 (Uniform State Plumbing Code, 2023), NFPA 54 (2012), NFPA 58 (2011), and MGL c.142.
  • Apply to the Board through the eLIPSE portal. After you pass both parts, pay the license fee in eLIPSE. Exams are at PSI sites in Auburn, Boston, Fall River, Lawrence and West Springfield.

Frequently asked questions

What is on the Massachusetts master plumber exam?

Part 1 has 80 questions: gas piping, equipment and appliances 21, drain, waste and vent 13, venting 12, general regulations, inspections and permits 9, water supply 6, separators, interceptors and grease traps 5, water heaters 3, piping, valves and controls 3, and smaller sections for traps, fixtures, hangers and joints.

Is it open book?

No. Both parts are closed book.

Is Part 2 different from the journeyman Part 2?

No. The PSI bulletin lists one plumber Part 2 (40 questions) for both journeyman and master applicants.

Free questions with answers

Show all 10 free questions and answers
  1. A master plumber wants Board permission to use a non-code piping system. She expects to use it on many jobs at different sites and needs to prove its feasibility first. Which Board mechanism under 248 CMR 3.04 fits, and why?

    Answer: A Test-site, because it is appropriate when the alternative may be used for more than one installation at more than one location

    A Variance covers one instance at one location (unusual circumstance or hardship). A Test-site is for an alternative method, material, system or technology likely to be used in multiple installations and locations. Work cannot begin until the Board votes to grant it, and the request is made before the permit application.

    Reference: 248 CMR 3.00 (eff. 4/30/2021), 248 CMR 3.04(2)(a) and 3.04(4)(b)

  2. A master plumber plans a new gas piping system rated at 6,500,000 Btu/hr. Before the Inspector will issue the permit, what must be submitted with the engineer-stamped drawings under 248 CMR 5.05(1)?

    Answer: A written statement from the serving gas supplier that it can deliver the required volume, pressure and demand

    Systems over 5,000,000 Btu/hr must be designed by a Massachusetts registered professional engineer. The installer gives the Inspector the stamped drawings and a written statement from the serving gas supplier that it can provide the volume, pressure and maximum gas demand needed, including for existing systems. This replaces NFPA 54 5.1.1.

    Reference: 248 CMR 5.00 (NFPA 54 amendments), 248 CMR 5.05(1)(a)

  3. A through-the-wall gas vent terminates 7.5 feet above finished grade on a residence. Under 248 CMR 5.12(6), is the 'GAS VENT DIRECTLY BELOW' identification plate required?

    Answer: No; it is required only when the terminal is under seven feet above finished grade

    Section 12.9.7 applies whenever a through-the-wall vent is installed less than seven feet above finished grade. Then a metal or plastic plate is mounted outside, at least eight feet above grade in line with the terminal, with lettering not smaller than 0.5 inch. At 7.5 feet the plate is not required.

    Reference: 248 CMR 5.00 (NFPA 54 amendments), 248 CMR 5.12(6) (NFPA 54 12.9.7)

  4. Two back-to-back fixtures (other than water closets) are served by one fitting on a vertical drain. Which fitting does 248 CMR 10.15(8)(b) require?

    Answer: A double sanitary drainage pattern tee

    Back-to-back fixtures on a vertical drain use a double sanitary drainage pattern tee; on horizontal piping only double sanitary wyes are allowed, to eliminate throw-over. The exception lets water closets use double wyes if the toilet manufacturer's instructions require it.

    Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.15(8)(b)

  5. A combination sink and wash tray has compartments whose waste outlets are 26 inches apart, and one compartment is 5 inches deeper than the other. Under 248 CMR 10.08(2)(a)1, how may it be trapped?

    Answer: On one trap, since the depth difference is under six inches and outlets are under 30 inches apart

    A combination fixture may use one trap if one compartment is not more than six inches deeper than the other and the waste outlets are not more than 30 inches apart. Here the 5 inch difference and 26 inch spacing both meet the limits. Otherwise each fixture needs its own trap set as close to the outlet as possible.

    Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.08(2)(a)1.a.ii

  6. A master plumber sets the tempering valves for lavatories in an office building's public restrooms and in a single-family home. Under 248 CMR 10.10(10)(a) and (b), what are the maximum hot water temperatures at these lavatories?

    Answer: 120 degrees F for public and employee; 130 degrees F for residential

    Public and employee lavatories are limited to 120 degrees F hot water (and faucets to 0.5 GPM); residential lavatories are limited to 130 degrees F, which matches the residential limit in 248 CMR 10.14(5)(c).

    Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.10(10)(a) and (b)

  7. A grease interceptor is installed outside a building as required by another agency. What chamber vent does 248 CMR 10.09(1)(b)12 require?

    Answer: A vent of at least 4 inches, piped to the inside of the building under 10.16

    An outside grease interceptor or trap needs a chamber vent of at least four inches in diameter, piped to the inside of the building in compliance with 248 CMR 10.16; it may connect into the building's sanitary venting system.

    Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.09(1)(b)12.b

  8. How must the discharge from a temperature and pressure relief valve on a water heater be piped under 248 CMR 10.14(6)(f)2.c?

    Answer: Full size, non-ferrous or rated tubing, no shutoff, ending within 12 inches of the floor

    The T&P valve discharge outlet must be full size and piped in non-ferrous material or tubing rated to withstand the maximum relief valve temperature, with no shutoff, to a fixture or to a point within twelve inches of the floor.

    Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.14(6)(f)2.c

  9. A building water system has solenoid valves and quick-closing valves. What does 248 CMR 10.14(2)(b) require?

    Answer: Rechargeable air chambers or product-accepted mechanical devices, near the valves and accessible

    Systems with quick-acting or solenoid valves need devices to absorb the pressure surge: air chambers provided with a means to restore air if waterlogged, or other Product-accepted mechanical devices, placed as close as possible to the valves and accessible for maintenance or replacement.

    Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.14(2)(b)

  10. A pressure reducing valve is installed to cut the building water pressure to 80 psig. What else must be installed under 248 CMR 10.14(2)(e)?

    Answer: A gauge of at least 0-150 psig range within 24 inches downstream of the valve

    Where pressure exceeds 80 psig at any fixture, device or appurtenance, a pressure reducing valve limits it to 80 psig upstream of the device, and a gauge with a minimum range of 0-150 psig is installed within 24 inches downstream of the valve. Piping upstream and downstream of a booster is exempt.

    Reference: 248 CMR 10.00 Uniform State Plumbing Code (2023), 248 CMR 10.14(2)(e)

Sources

Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.