Requirements at a glance
| Agency | Board of State Examiners of Plumbers and Gas Fitters (Division of Occupational Licensure); exams by PSI |
|---|---|
| License | Journeyman Gas Fitter |
| Format | Part 1: 60 questions, 120 minutes, closed book, 70% to pass |
| Fees | $80 PSI exam fee; the license fee in eLIPSE is $52 (journeyman, gas fitter, LP gas installer), $78 (master plumber) or $97 (master gas fitter) |
Gas fitting apprentices applying for a Massachusetts journeyman gas fitter license from the Board of State Examiners of Plumbers and Gas Fitters.
Official links
How to get licensed, step by step
Apply to the Board
Apply online through eLIPSE with your apprenticeship hours and education. The Board approves you, then PSI contacts you to schedule.
Board of State Examiners of Plumbers and Gas Fitters (opens in a new tab)
Schedule the journeyman gas fitter exam with PSI
Test at a PSI site in Auburn, Boston, Fall River, Lawrence or West Springfield. Cancel at least 2 days ahead or you forfeit the fee.
Schedule with PSI (Massachusetts plumbers and gas fitters) (opens in a new tab)
Pass both parts
Each part is scored separately at 70%. Retake within 12 months of approval; after six failed attempts you must petition the Board in writing.
Schedule with PSI (Massachusetts plumbers and gas fitters) (opens in a new tab)
Get licensed
Pay the license fee in eLIPSE after you pass both parts.
Board of State Examiners of Plumbers and Gas Fitters (opens in a new tab)
How to prepare
- Both parts are closed book. Nothing is allowed in the room, so learn the code rules and numbers rather than where to find them.
- The editions are 248 CMR 3.00, 4.00, 5.00 and 11.00 (2021), 10.00 (2023 plumbing code), NFPA 54 (2012) and NFPA 58 (2011).
- Gas piping, equipment and appliances is 38 of the 60 questions: design and materials, testing and purging, underground piping, CSST, regulators, combustion air and the 248 CMR 4.00 and 5.00 changes to NFPA 54.
- Venting (15) covers natural draft, positive and non-positive systems, chimneys and sizing.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
248 CMR 3.00 to 11.00: Massachusetts plumbing and gas rulesEssential
Not allowed in the exam room (closed book). The core of both plumbing and gas exams: Uniform State Plumbing Code (10.00, 2023), Fuel Gas Code (4.00 and 5.00, 2021), 6.00, 7.00 and 11.00.
Massachusetts regulations (Cornell LII, free to read) (opens in a new tab)
MGL Chapter 142: Supervision of Plumbing
Not allowed in the exam room. Licensing, permits and the water heater rules.
Massachusetts General Laws (free to read) (opens in a new tab)
Official reference list (as published by the testing agency)
- 248 CMR 3.00 (2021), 4.00 (2021 Massachusetts Fuel Gas Code), 5.00 (2021 amendments to NFPA 54), 6.00 (2014 amendments to NFPA 58), 7.00 (2014 large gas utilization equipment) and 11.00 (2021)
- NFPA 54 National Fuel Gas Code (2012) and NFPA 58 Liquefied Petroleum Gas Code (2011)
- MGL Chapter 142: Supervision of Plumbing, and the general provisions governing plumbing and gas work
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Regulations, Inspections, and Permits | 7 | |
| Gas Piping, Equipment, and Appliances | 38 | |
| Venting | 15 |
Exam day details
- Administered by PSI Services for the Massachusetts Board of State Examiners of Plumbers and Gas Fitters.
- Fee: $80 PSI exam fee (retakes pay again, non-refundable). Board application and the license fee ($52 for journeyman) are separate.
- 60 questions in 120 minutes; 70% to pass. This is Part 1 (Written). Part 2 (20 questions in 80 minutes on gas piping, gas venting, and combustion, dilution and ventilation air) is not part of this practice bank.
- Closed book and two parts. Each part is scored on its own and you must pass both. Nothing is allowed in the exam room, and a silent non-programmable calculator is the only aid.
- If you fail, retake within 12 months of your application approval date. After six failed attempts you must petition the Board in writing before more attempts.
- The references are 248 CMR 3.00, 4.00, 5.00 and 11.00 (2021), 6.00 (2014 NFPA 58 amendments), 7.00 (2014 large gas equipment), 10.00 (Uniform State Plumbing Code, 2023), NFPA 54 (2012), NFPA 58 (2011), and MGL c.142.
- Apply to the Board through the eLIPSE portal. After you pass both parts, pay the license fee in eLIPSE. Exams are at PSI sites in Auburn, Boston, Fall River, Lawrence and West Springfield.
Frequently asked questions
What is on the Massachusetts journeyman gas fitter exam?
Part 1 has 60 questions: gas piping, equipment and appliances 38, venting 15, and general regulations, inspections and permits 7.
Is the gas fitter exam open book?
No. Both parts are closed book.
Which code editions does it use?
The 2021 248 CMR sections (including the Massachusetts Fuel Gas Code) on top of NFPA 54 (2012) and NFPA 58 (2011), per the 10/3/2025 PSI bulletin.
Free questions with answers
Show all 10 free questions and answers
A licensed gas fitter will install new gas piping in a privately owned retail building in a Massachusetts town. Who receives the permit application and performs the inspection?
Answer: The Local Inspector appointed by the city or town
Permit applications for buildings that are not owned, used, leased or built by the Commonwealth (or the federal government) go to the Local Inspector, who grants or denies the permit and does the inspections. State Inspectors cover state-owned, used, leased or constructed buildings only.
Reference: 248 CMR 3.00 (2021), General Provisions Governing Plumbing and Gas Fitting Work, 248 CMR 3.05(1)(a)
A gas fitting permit was issued on March 1, but the job was delayed and no work has started by early June, more than 90 days later. What is the status of the permit?
Answer: It is invalid unless the holder proves the delay was beyond his or her control
A permit is invalid if work is not started within 90 days of the date of the permit, unless the holder satisfactorily shows the failure to start was beyond his or her control. There is no automatic renewal or one-year validity period.
Reference: 248 CMR 3.00 (2021), General Provisions Governing Plumbing and Gas Fitting Work, 248 CMR 3.05(1)(e)
Within how many working days after receiving a permit application from a licensee must the Inspector act on it?
Answer: Two working days
The Inspector must act within two working days of receipt. Acting does not mean the permit is approved or issued. The 30-day period in the code is the time the Inspector may spend reviewing required plans, not the response time.
Reference: 248 CMR 3.00 (2021), General Provisions Governing Plumbing and Gas Fitting Work, 248 CMR 3.05(1)(f)
Under the Massachusetts Fuel Gas Code, what is the standard maximum operating pressure for gas piping systems unless they are designed as elevated pressure systems?
Answer: 0.5 psig (14 inches water column)
248 CMR 4.03(1)(b) replaces NFPA 54 1.1.1.1(B): all gas piping systems must be low pressure, not over 0.5 psig or 14 inches water column, unless designed and installed under 248 CMR 5.05(4)(B) as elevated pressure systems.
Reference: 248 CMR 4.00 (2021), Massachusetts Fuel Gas Code, 248 CMR 4.03(1)(b)
Using the Massachusetts diversity factor table for domestic ranges in multi-family dwellings (63,000 Btu/hr or more per range), what demand in cubic feet per hour applies to a riser serving 8 ranges?
Answer: 212 cubic feet per hour
Table 5.4.2.3 lists 8 ranges at 42 percent with a demand of 212 cubic feet per hour. Eight ranges at 63 cubic feet per hour each is 504 cubic feet per hour with no diversity, and 504 x 0.42 = 211.7, about 212. The 189 figure belongs to 6 ranges and 252 to a 50 percent factor.
Reference: 248 CMR 5.00 (2021), Amendments to NFPA 54, 248 CMR 5.05(3), Table 5.4.2.3
The diversity factor in Table 5.4.2.3 can be used to reduce the load when sizing piping for which of the following?
Answer: Domestic gas ranges in multi-family dwellings only
The diversity factor applies to domestic ranges in multiple family dwellings only. It does not apply to any other gas appliances, so dryers, water heaters, furnaces and commercial equipment are sized at their full connected load.
Reference: 248 CMR 5.00 (2021), Amendments to NFPA 54, 248 CMR 5.05(3)
What does 248 CMR 5.05(7) say about galvanized pipe in a fuel gas system?
Answer: Galvanized pipe shall not be used
248 CMR 5.05(7) adds 5.6.2.7: galvanized pipe shall not be used. This is a Massachusetts rule with no exception for outdoor use or low pressure.
Reference: 248 CMR 5.00 (2021), Amendments to NFPA 54, 248 CMR 5.05(7), NFPA 54 5.6.2.7
Gas appliances vent through a hood exhaust system with a power means of exhaust. What must the gas line include under 248 CMR 5.12(1)?
Answer: A solenoid valve that cannot be bypassed
12.4.4.2 as replaced requires gas to flow to the main burners only when the damper is open or the power exhaust is operating. All gas lines serving such appliances need a solenoid valve that is not bypassed, with a manual reset controlled by an interlocked hard-wired CO detector or a draft proving switch.
Reference: 248 CMR 5.00 (2021), Amendments to NFPA 54, 248 CMR 5.12(1), 12.4.4.2
An existing tile-lined chimney will be reused for a replacement gas appliance. Which of the following is one of the Massachusetts conditions?
Answer: The chimney area is no more than seven times the smallest flue area connected to it
The 12.6.4.2 exception as replaced allows reuse only if the existing appliance operated with non-positive vent static pressure that did not create condensation, the chimney is not used when replacing an atmospheric appliance with a fan-assisted one, and its interior area is no greater than seven times the area of the smallest flue connected to it.
Reference: 248 CMR 5.00 (2021), Amendments to NFPA 54, 248 CMR 5.12(3), 12.6.4.2 Exception
What is the minimum distance from a sidewall horizontal exhaust vent terminal or intake to a gas meter under 248 CMR 5.12(7)?
Answer: Three feet
12.9.8 as added: a sidewall horizontal exhaust vent termination or intake for gas-fueled equipment must be at least three feet from a gas meter. Snow-line heights follow the manufacturer, town ordinance, or National Weather Service ten year statistics.
Reference: 248 CMR 5.00 (2021), Amendments to NFPA 54, 248 CMR 5.12(7), 12.9.8
Sources
- PSI: Massachusetts Plumbers and Gas Fitters Candidate Information Bulletin (10/3/2025) (opens in a new tab)
- Massachusetts Board of State Examiners of Plumbers and Gas Fitters (opens in a new tab)
- 248 CMR (Plumbers and Gas Fitters), Cornell LII (opens in a new tab)
Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.