Requirements at a glance
| Agency | Maryland State Board of HVACR Contractors; exam by PSI |
|---|---|
| Experience | Master restricted: licensed and regularly employed as a journeyman, limited contractor or master restricted contractor for at least 3 years with at least 1,875 hours of HVACR work (or 6 years of documented experience). Journeyman restricted: a Maryland apprentice license for at least 3 years with 1,875 hours of training, or an approved apprentice program. |
| Exam | 50 questions, 2 hours, 70% to pass (master and journeyman restricted share one outline) |
| Books allowed | 2012 or 2018 IMC, Modern Refrigeration and Air Conditioning (19th to 21st edition), Manual J (8th edition) and 29 CFR 1926 |
| Fees | $50 to PSI, plus Board application and license fees |
HVACR workers applying for a Maryland master restricted or journeyman restricted license in the air conditioning specialty from the State Board of HVACR Contractors.
Official links
How to get licensed, step by step
Confirm you qualify
Master restricted: licensed and regularly employed as a journeyman, limited contractor or master restricted contractor for at least 3 years with at least 1,875 hours of HVACR work (or 6 years of documented experience). Journeyman restricted: a Maryland apprentice license for at least 3 years with 1,875 hours of training, or an approved apprentice program.
Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)Maryland Code (General Assembly) (opens in a new tab)
Apply through PSI
Submit the exam application online at the PSI site below (mailed or faxed applications are returned). PSI and the Board review your documents, then email you how to pay and schedule.
Pass the open-book exam
Exam fees are non-refundable and non-transferable. Exam fees are valid for 90 days, and you may not test more often than every 30 days.
Apply for the license
After you pass, the Board sends you the license application. Pay the license fee and file any required insurance.
Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)
How to prepare
- Tab your books before exam day: permanent plastic tabs (Avery Swift or Redi-Tag), highlighting and underlining are allowed; Post-It flags and writing in the book are not.
- Refrigeration and air conditioning (20) and electrical knowledge, motors and controls (15) are 70% of the exam; piping is 10 and safety 5.
- The practice bank does not quote Modern Refrigeration, Manual J, Stoecker, NAIMA or SMACNA (copyrighted); use those books in your tabs for the matching topics.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Official reference list (as published by the testing agency)
- International Mechanical Code (IMC), 2012 or 2018 edition (allowed in the exam room)
- Modern Refrigeration and Air Conditioning, 19th, 20th or 21st edition, Goodheart-Willcox (allowed in the exam room)
- Manual J: Residential Load Calculation, 8th edition (2006), ACCA (allowed in the exam room)
- 29 CFR Part 1926 (OSHA construction standards), with latest amendments, or the PSI selections (allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Electrical Knowledge, Motors, and Controls | 15 | |
| Piping | 10 | |
| Refrigeration and Air Conditioning | 20 | |
| Safety | 5 |
Exam day details
- Administered by PSI Services for the Maryland State Board of HVACR Contractors.
- Fee: $50 to PSI per exam. Board application and license fees are separate.
- 50 questions in 2 hours; 35 correct (70%) to pass. The master restricted and journeyman restricted air conditioning exams use the same outline.
- The master restricted and journeyman restricted exams in each specialty share one content outline, so this page covers both levels.
- Master restricted eligibility: licensed by the Board and regularly employed as a journeyman, limited contractor or master restricted contractor (any specialty) for at least 3 years, under a master contractor or a master restricted contractor in the same specialty, with at least 1,875 hours of HVACR work. Others may apply with 6 years of documented HVACR experience.
- Journeyman restricted eligibility: a Maryland HVACR apprentice license for at least 3 years with at least 1,875 hours of training under a licensed contractor (or a master restricted contractor in the same category), or a Board-approved apprentice program or approved coursework combination. Others may apply to the Board with documented experience.
- Open book: you may bring only the listed references (none are provided), which you may index, highlight and underline but not write in. Study guides are not allowed.
- Exam fees are valid for 90 days and for one examination only; they are not refundable or transferable.
- You may not take an HVACR exam more often than every 30 days.
- Master, master restricted and limited contractors who own the business or pull permits must carry $300,000 personal liability and $100,000 property damage insurance ($400,000 combined per occurrence).
- About the practice questions: they are written from the IMC, 29 CFR 1926 and the Maryland HVACR statute and regulations. Modern Refrigeration and Air Conditioning, Manual J, Stoecker, NAIMA and SMACNA are copyrighted, so they are not quoted in the bank; open those books for the matching topics.
Frequently asked questions
What's on the Maryland restricted air conditioning exam?
50 questions: refrigeration and air conditioning 20, electrical knowledge, motors and controls 15, piping 10 and safety 5.
Is the journeyman restricted exam different?
The Board prints one outline for both levels, so this page covers the master restricted and journeyman restricted air conditioning exams.
Free questions with answers
Show all 10 free questions and answers
A 24-volt contactor coil draws 0.5 ampere when energized. Using Ohm's law, what is the resistance of the coil?
Answer: 48 ohms
Ohm's law gives R = E / I = 24 / 0.5 = 48 ohms. Multiplying the two numbers gives 12 ohms, which is a power-like value rather than a resistance, and 0.02 ohm comes from dividing the current by the voltage.
Reference: DOE Fundamentals Handbook, Electrical Science, DOE-HDBK-1011/1-92, Module 2, Basic DC Theory (Ohm's law)
Three heating elements rated 15, 15 and 30 ohms are connected in series across a 120-volt source. What current flows in the circuit?
Answer: 2 amperes
Series resistances add: 15 + 15 + 30 = 60 ohms. Current is I = E / R = 120 / 60 = 2 amperes. Dividing by only one 15-ohm element gives 8 A and dividing by 30 ohms gives 4 A, but the same current flows through every element in a series circuit.
Reference: DOE Fundamentals Handbook, Electrical Science, DOE-HDBK-1011/1-92, Module 3, DC Circuits (series circuits)
A single-phase 240-volt, 5-kW resistance heater is operating at full load. About how much current does it draw?
Answer: 20.8 amperes
For a resistive single-phase load I = P / E = 5,000 / 240 = 20.8 amperes. Using 120 volts would give 41.7 A, and dividing by 1.732 as if the load were three-phase would give 12.0 A.
Reference: DOE Fundamentals Handbook, Electrical Science, DOE-HDBK-1011/1-92, Module 2, Basic DC Theory (power relationships)
A 3/4-inch CPVC condensate drain runs horizontally along a joist. What is the maximum support spacing allowed by the IMC table?
Answer: 3 feet
Table 305.4 gives CPVC pipe or tubing 1 inch and smaller a 3-foot maximum horizontal spacing; sizes 1 1/4 inches and larger may go 4 feet. Eight feet applies to copper tubing, not plastic condensate piping.
Reference: 2018 International Mechanical Code (IMC), Table 305.4
A condensate drain from a basement air handler runs 40 feet horizontally to a floor drain at the code-minimum slope of 1/8 unit vertical in 12 units horizontal. How much total drop is needed over the run?
Answer: 5 inches
Section 307.2.1 sets the minimum condensate drain slope at 1/8 inch per foot (1 percent). 40 feet x 1/8 inch = 5 inches of drop. Using 1/16 inch per foot gives 2 1/2 inches, using 1/4 inch per foot (the plumbing-drain habit) gives 10 inches, and dividing 40 by 12 gives 3 1/3 inches, which is not a slope calculation.
Reference: 2018 International Mechanical Code (IMC), Section 307.2.1
A coil cools 1,600 cfm of air by 18 degrees F with no moisture removal. Using Q = 1.08 x cfm x temperature difference, how much sensible heat is removed?
Answer: 31,104 BTU/h
Q = 1.08 x 1,600 x 18 = 1,728 x 18 = 31,104 BTU/h. 1,728 is the result before multiplying by the temperature difference, and 34,560 would result from using a 20-degree difference.
Reference: Engineering ToolBox, Cooling and Heating Equations, Sensible heat, Imperial equation (1b)
A cooling coil removes 32,400 BTU/h of sensible heat while lowering the air temperature 20 degrees F. Using Q = 1.08 x cfm x temperature difference, what is the airflow?
Answer: 1,500 cfm
Rearrange the formula: cfm = Q / (1.08 x delta T) = 32,400 / (1.08 x 20) = 32,400 / 21.6 = 1,500 cfm. Dividing by delta T alone gives 1,620 cfm, which leaves out the 1.08 factor.
Reference: Engineering ToolBox, Cooling and Heating Equations, Sensible heat, Imperial equation (1b)
A cooling coil removes 21,600 BTU/h of sensible heat and 42,000 BTU/h of total heat. What is its sensible heat ratio (SHR)?
Answer: 0.51
SHR = sensible heat / total heat = 21,600 / 42,000 = 0.51. Inverting the ratio gives 1.94, which cannot be an SHR because sensible heat cannot exceed total heat, and 0.49 is the latent fraction rather than the sensible one.
Reference: Engineering ToolBox, Cooling and Heating Equations, Sensible Heat Ratio, equation (5)
A technician is setting a condensing unit near the unprotected edge of a roof that is 14 feet above the ground. At what height above a lower level does OSHA require fall protection for construction work?
Answer: 6 feet or more
29 CFR 1926.501(b)(1) requires guardrail systems, safety net systems or personal fall arrest systems for each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level. Fall protection is therefore required at this 14-foot edge.
Reference: 29 CFR Part 1926 (OSHA construction standards), Section 1926.501(b)(1)
A recovery cylinder has a water capacity of 62.5 pounds, a tare weight of 30 pounds, and will hold refrigerant with a liquid density of 60 pounds per cubic foot at 130 degrees F. The cylinder must not exceed 80 percent of its internal volume. What is the maximum total cylinder weight? (Water density is 62.5 pounds per cubic foot.)
Answer: 78 pounds
Cylinder volume = 62.5 / 62.5 = 1.0 cubic foot. Maximum cylinder weight = (volume x liquid density x 0.80) + tare = (1.0 x 60 x 0.80) + 30 = 48 + 30 = 78 pounds. Leaving out the tare weight gives 48 pounds, and filling to 100 percent gives 90 pounds, which overfills the cylinder.
Reference: ACHR News, Examining Recovery Cylinder Capabilities (J. Marchese, 2007), Maximum cylinder weight formula (80 percent fill limit)
Sources
- PSI: Maryland HVACR Contractor Examinations Candidate Information Bulletin (updated 9/1/2024) (opens in a new tab)
- Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)
- Maryland General Assembly: Maryland Code (statutes) (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.