Requirements at a glance
| Agency | Maryland State Board of HVACR Contractors; exam by PSI |
|---|---|
| Experience | At least 3 years licensed and regularly employed as a journeyman, limited contractor, master restricted contractor or HVACR instructor, with at least 1,875 hours of HVACR work under a licensed master contractor. |
| Exam | 100 questions, 4 hours, 70% to pass |
| Books allowed | 2012 or 2018 IMC, Modern Refrigeration and Air Conditioning (19th to 21st edition), Manual J (8th edition), 29 CFR 1926 and the ACCA Ductulator |
| Fees | $150 to PSI, plus Board application and license fees; $300,000 liability and $100,000 property damage insurance if you own the business or pull permits |
HVACR professionals applying for a Maryland master HVACR contractor license from the State Board of HVACR Contractors, usually after 3 years licensed as a journeyman, limited or master restricted contractor.
Official links
How to get licensed, step by step
Confirm you qualify
At least 3 years licensed and regularly employed as a journeyman, limited contractor, master restricted contractor or HVACR instructor, with at least 1,875 hours of HVACR work under a licensed master contractor.
Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)Maryland Code (General Assembly) (opens in a new tab)
Apply through PSI
Submit the exam application online at the PSI site below (mailed or faxed applications are returned). PSI and the Board review your documents, then email you how to pay and schedule.
Pass the open-book exam
Exam fees are non-refundable and non-transferable. Exam fees are valid for 90 days, and you may not test more often than every 30 days.
Apply for the license
After you pass, the Board sends you the license application. Pay the license fee and file any required insurance.
Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)
How to prepare
- Tab your books before exam day: permanent plastic tabs (Avery Swift or Redi-Tag), highlighting and underlining are allowed; Post-It flags and writing in the book are not.
- Refrigeration and air conditioning (25) and electrical knowledge, motors and controls (20) are almost half the exam: know the refrigeration cycle, superheat and subcooling, and control wiring.
- Heating systems (20), piping (15) and air distribution (15) draw on the IMC and Modern Refrigeration; practice duct sizing with the ACCA Ductulator and load estimates with Manual J.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Mechanical Code (IMC), 2012 or 2018 EditionEssential
Allowed in the exam room. Piping, heating, air distribution and safety questions.
Modern Refrigeration and Air Conditioning, 22nd Edition (Goodheart-Willcox)
Refrigeration cycle, troubleshooting, piping and controls.
ACCA Manual J (8th), Manual D (3rd), Manual S (2nd) and the ACCA duct slide rule
Load calculations, duct design and equipment selection.
29 CFR 1926 (OSHA Construction Standards), sections on your reference list
Trenching, scaffolds, fall protection and ladders. Print just the listed sections.
Official reference list (as published by the testing agency)
- International Mechanical Code (IMC), 2012 or 2018 edition (allowed in the exam room)
- Modern Refrigeration and Air Conditioning, 19th, 20th or 21st edition, Goodheart-Willcox (allowed in the exam room)
- Manual J: Residential Load Calculation, 8th edition (2006), ACCA (allowed in the exam room)
- 29 CFR Part 1926 (OSHA construction standards), with latest amendments, or the PSI selections (allowed in the exam room)
- ACCA Ductulator (duct slide rule) (allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Electrical Knowledge, Motors, and Controls | 20 | |
| Piping | 15 | |
| Refrigeration and Air Conditioning | 25 | |
| Heating Systems | 20 | |
| Air Distribution Systems | 15 | |
| Safety | 5 |
Exam day details
- Administered by PSI Services for the Maryland State Board of HVACR Contractors.
- Fee: $150 to PSI. Board application and license fees are separate.
- 100 questions in 4 hours; 70 correct (70%) to pass.
- Eligibility: licensed and regularly employed as a journeyman, limited contractor, master restricted contractor or HVACR instructor for at least 3 years, with at least 1,875 hours of HVACR work under a licensed master contractor before you apply.
- Open book: you may bring only the listed references (none are provided), which you may index, highlight and underline but not write in. Study guides are not allowed.
- Exam fees are valid for 90 days and for one examination only; they are not refundable or transferable.
- You may not take an HVACR exam more often than every 30 days.
- Master, master restricted and limited contractors who own the business or pull permits must carry $300,000 personal liability and $100,000 property damage insurance ($400,000 combined per occurrence).
Frequently asked questions
What's on the Maryland master HVACR exam?
100 questions: refrigeration and air conditioning 25, electrical knowledge, motors and controls 20, heating systems 20, piping 15, air distribution systems 15 and safety 5.
Which IMC edition is allowed?
The bulletin allows the 2012 or the 2018 International Mechanical Code.
Is there a master restricted option?
Yes. The Board also gives master restricted exams for air conditioning, forced air heating, hydronic heating, refrigeration and ventilation. This page covers the full master contractor exam.
Free questions with answers
Show all 10 free questions and answers
A 24-volt control transformer feeds a contactor coil with a resistance of 8 ohms. How much current does the coil draw?
Answer: 3 amperes
Ohm's law gives I = E / R = 24 V / 8 ohms = 3 A. Dividing the resistance by the voltage (8/24 = 0.33 A) inverts the relationship, and multiplying 24 x 8 = 192 treats current as the product of volts and ohms.
Reference: DOE Fundamentals Handbook, Electrical Science (DOE-HDBK-1011/1-92), Module 1, Units of Electrical Measurement: Ohm's Law, Equation (1-4)
A balanced three-phase 208-volt electric heater is rated 18 kW and is purely resistive. Using I = P / (1.732 x E), what is the line current?
Answer: 50 amperes
I = 18,000 W / (1.732 x 208 V) = 18,000 / 360.3 = 49.96, about 50 A. Dividing by the voltage alone (18,000 / 208 = 86.5 A) leaves out the 1.732 factor, 18,000 / (3 x 208) = 28.8 A wrongly uses 3 instead of the square root of 3, and 75 A is 18,000 / 240, the wrong voltage with no 1.732 factor.
Reference: DOE Fundamentals Handbook, Electrical Science (DOE-HDBK-1011/1-92), Module 9, Basic AC Power: Three-Phase Circuits
What is the maximum vertical support spacing for PVC pipe under the IMC piping-support table?
Answer: 10 feet
Table 305.4 lists PVC pipe at 4 feet horizontally and 10 feet vertically (footnote c refers to mid-story guides). Four feet is the horizontal figure; 15 feet is the vertical spacing for steel and cast-iron pipe.
Reference: 2018 International Mechanical Code (IMC), Table 305.4
A low-pressure hydronic system has a maximum design pressure of 50 psi. What is the minimum required hydrostatic test pressure under the IMC?
Answer: 100 psi
One and one-half times 50 psi is 75 psi, but Section 1208.1 sets a floor of not less than 100 psi, so 100 psi governs, held at least 15 minutes. Seventy-five psi ignores the minimum, and 150 psi would be three times the design pressure.
Reference: 2018 International Mechanical Code (IMC), Section 1208.1
A coil cools 1,200 cfm of air by 20 degrees F with no moisture removal. Using the sensible-heat formula Q = 1.08 x cfm x temperature difference, how much sensible heat is removed?
Answer: 25,920 BTU/h
Q = 1.08 x 1,200 cfm x 20 degrees F = 25,920 BTU/h. Using 1.0 as the constant gives 24,000, which neglects the standard-air factor of 1.08. Dropping a 2 gives 12,960, and misplacing the decimal gives 259,200.
Reference: Engineering ToolBox, Cooling and Heating Equations, Sensible Heat, Imperial units: hs = 1.08 q dt (Eq. 1b)
A technician measures a suction line temperature of 52 degrees F at the compressor. The suction pressure gauge corresponds to a saturation temperature of 40 degrees F. What is the superheat?
Answer: 12 degrees F
Superheat is the actual vapor temperature minus the saturation (boiling) temperature at that pressure: 52 - 40 = 12 degrees F. Adding the two gives 92, 40 is simply the saturation temperature, and 8 degrees F is an arithmetic slip, not the 12-degree difference.
Reference: Copeland Refrigeration Manual Part 1 (AE101), Fundamentals of Refrigeration, 2024, Section 1, Superheated Vapor
An oil burner is fitted with a 0.75 gallon-per-hour nozzle at its rated pressure. Using 140,000 BTU per gallon of No. 2 fuel oil, what is the burner input?
Answer: 105,000 BTU/h
Penn State gives about 140,000 BTU of heat energy per gallon of #2 fuel oil, so the burner input is the gallons burned per hour times the heat in each gallon: 0.75 x 140,000 = 105,000 BTU/h. Dividing 140,000 by 0.75 gives 186,667 and inverts the relationship, 140,000 is the input of a 1.00 gph nozzle, and 10,500 shifts the decimal.
Reference: Penn State EGEE 102: Energy Conservation for Environmental Protection, 9.6 Home Heating Fuels, Fuel Oil: one gallon of #2 fuel oil contains about 140,000 BTU
A hot-water boiler must deliver 100,000 BTU/h to a baseboard loop with a 20 degree F temperature drop. Using Q = 500 x gpm x delta T, what flow rate is required?
Answer: 10 gpm
Rearranging, gpm = Q / (500 x delta T) = 100,000 / (500 x 20) = 100,000 / 10,000 = 10 gpm. Five gpm would be correct for a 40 degree drop, 20 gpm for a 10 degree drop, and 1 gpm drops a zero.
Reference: Red Seal Steamfitter/Pipefitter Formula Sheet, Heat transfer: gpm = Btuh / (500 x temp. diff.)
What marking identifies a pressure-sensitive tape listed for sealing metal and flexible ducts under UL 181B?
Answer: 181B-FX
Section 603.9 requires tapes and mastics for metallic and flexible ducts to meet UL 181B and be marked 181B-FX for pressure-sensitive tape or 181B-M for mastic. The 181A-P, 181A-M and 181A-H marks apply to fibrous glass duct systems.
Reference: 2018 International Mechanical Code (IMC), Section 603.9
A portable ladder is used to reach a rooftop unit's upper landing. How far must the side rails extend above the upper landing surface (unless the ladder is secured at its top with a grab rail)?
Answer: At least 3 feet
Section 1926.1053(b)(1) requires portable ladder side rails to extend at least 3 feet above the upper landing surface, or the ladder must be secured at its top to a rigid support with a grasping device provided.
Reference: 29 CFR Part 1926 (OSHA construction standards), 29 CFR 1926.1053(b)(1)
Sources
- PSI: Maryland HVACR Contractor Examinations Candidate Information Bulletin (updated 9/1/2024) (opens in a new tab)
- Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)
- Maryland General Assembly: Maryland Code (statutes) (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.