Maryland licensing exam

Maryland HVACR Journeyman Exam: Practice Test & Licensing Guide

The PSI exam for the Maryland HVACR journeyman license: 100 questions on refrigeration and air conditioning, electrical controls, heating, piping and air distribution. Open book, 70% to pass.

Questions
100
Time limit
4 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Electrical Knowledge, Motors, and Controls

A 240-volt electric heating element draws 12 amperes. What is the resistance of the element?

Requirements at a glance

AgencyMaryland State Board of HVACR Contractors; exam by PSI
ExperienceA Maryland HVACR apprentice license for at least 3 years with at least 1,875 hours of training under a licensed HVACR contractor, a Board-approved apprentice program, or a combination of apprentice time and approved coursework totaling 3 years. Others may apply to the Board with 3 years of documented experience.
Exam100 questions, 4 hours, 70% to pass
Books allowed2012 or 2018 IMC, Modern Refrigeration and Air Conditioning (19th to 21st edition), Manual J (8th edition), 29 CFR 1926 and the ACCA Ductulator
Fees$150 to PSI, plus Board application and license fees

HVACR technicians applying for a Maryland journeyman license from the State Board of HVACR Contractors, usually after 3 years as a licensed HVACR apprentice with at least 1,875 hours of training under a licensed contractor.

How to get licensed, step by step

  1. Confirm you qualify

    A Maryland HVACR apprentice license for at least 3 years with at least 1,875 hours of training under a licensed HVACR contractor, a Board-approved apprentice program, or a combination of apprentice time and approved coursework totaling 3 years. Others may apply to the Board with 3 years of documented experience.

    Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)Maryland Code (General Assembly) (opens in a new tab)

  2. Apply through PSI

    Submit the exam application online at the PSI site below (mailed or faxed applications are returned). PSI and the Board review your documents, then email you how to pay and schedule.

    Schedule with PSI (HVACR contractors) (opens in a new tab)

  3. Pass the open-book exam

    Exam fees are non-refundable and non-transferable. Exam fees are valid for 90 days, and you may not test more often than every 30 days.

    Schedule with PSI (HVACR contractors) (opens in a new tab)

  4. Apply for the license

    After you pass, the Board sends you the license application. Pay the license fee and file any required insurance.

    Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)

How to prepare

  • Tab your books before exam day: permanent plastic tabs (Avery Swift or Redi-Tag), highlighting and underlining are allowed; Post-It flags and writing in the book are not.
  • Refrigeration and air conditioning (25) and electrical knowledge, motors and controls (20) are almost half the exam: know the refrigeration cycle, superheat and subcooling, and control wiring.
  • Heating systems (20), piping (15) and air distribution (15) draw on the IMC and Modern Refrigeration; practice duct sizing with the ACCA Ductulator.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Mechanical Code (IMC), 2012 or 2018 edition (allowed in the exam room)
  • Modern Refrigeration and Air Conditioning, 19th, 20th or 21st edition, Goodheart-Willcox (allowed in the exam room)
  • Manual J: Residential Load Calculation, 8th edition (2006), ACCA (allowed in the exam room)
  • 29 CFR Part 1926 (OSHA construction standards), with latest amendments, or the PSI selections (allowed in the exam room)
  • ACCA Ductulator (duct slide rule) (allowed in the exam room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Electrical Knowledge, Motors, and Controls20
Piping15
Refrigeration and Air Conditioning25
Heating Systems20
Air Distribution Systems15
Safety5

Exam day details

  • Administered by PSI Services for the Maryland State Board of HVACR Contractors.
  • Fee: $150 to PSI. Board application and license fees are separate.
  • 100 questions in 4 hours; 70 correct (70%) to pass. The journeyman outline matches the master outline.
  • Eligibility: a Maryland HVACR apprentice license for at least 3 years with at least 1,875 hours of training under a licensed HVACR contractor, a Board-approved apprentice program, or a combination of apprentice time and approved coursework totaling 3 years. Applicants outside these routes may apply to the Board with 3 years of documented qualifying experience.
  • Open book: you may bring only the listed references (none are provided), which you may index, highlight and underline but not write in. Study guides are not allowed.
  • Exam fees are valid for 90 days and for one examination only; they are not refundable or transferable.
  • You may not take an HVACR exam more often than every 30 days.

Frequently asked questions

What's on the Maryland HVACR journeyman exam?

100 questions: refrigeration and air conditioning 25, electrical knowledge, motors and controls 20, heating systems 20, piping 15, air distribution systems 15 and safety 5.

How is it different from the master HVACR exam?

The outline and reference list are the same. The difference is eligibility: the journeyman exam follows 3 years as an apprentice, while the master exam needs time as a licensed journeyman, limited or master restricted contractor.

Which books can I bring?

The 2012 or 2018 IMC, Modern Refrigeration and Air Conditioning (19th to 21st edition), Manual J (8th edition), 29 CFR Part 1926 and the ACCA Ductulator.

Free questions with answers

Show all 10 free questions and answers
  1. A 240-volt electric heating element draws 12 amperes. What is the resistance of the element?

    Answer: 20 ohms

    Ohm's law rearranged gives R = E / I = 240 V / 12 A = 20 ohms. Multiplying the two numbers (2,880) is the power-style mistake of combining volts and amps, dividing amps by volts (0.05) inverts the formula, and subtracting the values has no basis in the law.

    Reference: DOE Fundamentals Handbook, Electrical Science (DOE-HDBK-1011/1-92), Module 1, Units of Electrical Measurement: Ohm's Law, Equation (1-4)

  2. A 25 MFD, 370-volt run capacitor and a 15 MFD, 440-volt run capacitor are connected in parallel. What are the resulting capacitance and voltage rating?

    Answer: 40 MFD at 370 volts

    Parallel capacitors add their MFD ratings (25 + 15 = 40 MFD), and the combination is limited to the lowest voltage rating of the individual capacitors, 370 V. Adding the voltages (810 V) is the series rule for like capacitors, and 9.4 MFD is the series capacitance.

    Reference: Copeland Refrigeration Manual Part 2, Refrigeration System Components (2024), Section 10, Starting Equipment and Motor Protectors: Capacitors (parallel connection)

  3. Under the IMC piping support table, what is the maximum horizontal support spacing for steel pipe?

    Answer: 12 feet

    Table 305.4 lists steel pipe at 12 feet horizontal and 15 feet vertical. 8 feet is the horizontal figure for steel or copper tubing, 5 feet is cast-iron pipe, and 15 feet is steel pipe's vertical spacing, not its horizontal.

    Reference: 2018 International Mechanical Code (IMC), Table 305.4

  4. Which push-fit fitting type must not be used with PEX tubing that has an ethylene vinyl alcohol (EVOH) oxygen barrier layer?

    Answer: A push-fit that seals on the outside diameter of the tubing

    Section 1203.9.3 prohibits push-fit joints that create a seal on the outside diameter of the tubing with EVOH oxygen-barrier tubing, because the seal would bear on the barrier layer. Compression fittings must be installed with their inserts and ferrules or O-rings (Section 1203.9.1), which is a different rule.

    Reference: 2018 International Mechanical Code (IMC), Section 1203.9.3

  5. Refrigerant recovered from a customer's failed system is clean and has been filtered and dried. Where may it be reused without reclaiming?

    Answer: Only in the same system or in other systems of the same owner

    Section 1102.2.2.2 says recovered refrigerant shall not be reused in other than the system it came from and other systems of the same owner, and it must be filtered and dried before reuse. Used refrigerant going to a different owner must meet AHRI 700 purity as reclaimed refrigerant (Section 1102.2.2.3).

    Reference: 2018 International Mechanical Code (IMC), Sections 1102.2.2.2 and 1102.2.2.3

  6. Where must pressure relief devices and fusible plugs located in a refrigerant machinery room terminate?

    Answer: Outside, 15 feet above grade and 20 feet from any window, opening or exit

    Section 1105.7 requires pressure relief devices, fusible plugs and purge systems in the machinery room to terminate outside the structure, not less than 15 feet above the adjoining grade and not less than 20 feet from any window, ventilation opening or exit.

    Reference: 2018 International Mechanical Code (IMC), Section 1105.7

  7. What is the maximum control circuit voltage for a boiler electrical control system under the IMC?

    Answer: 150 volts nominal, line to line

    Section 1006.8 limits boiler control voltage to 150 volts nominal line to line. Control and limit devices must interrupt the ungrounded side of the circuit, and a manual disconnect for the control circuit that can be locked in the off position and has ready access must be provided.

    Reference: 2018 International Mechanical Code (IMC), Section 1006.8

  8. Using the IMC table for closed-type expansion tanks, what minimum pressurized diaphragm-type tank capacity serves a 400-gallon hot water system?

    Answer: 33 gallons

    Table 1009.2 lists a 400-gallon system volume with a 33-gallon pressurized diaphragm tank and a 60-gallon nonpressurized tank. 25 gallons is the diaphragm size for a 300-gallon system, 42 is the 500-gallon size, and 60 is the nonpressurized (plain) tank for 400 gallons.

    Reference: 2018 International Mechanical Code (IMC), Table 1009.2

  9. How much must crimped round metal duct joints be lapped, and which way must the male end point?

    Answer: At least 1 inch, with the male end extending in the direction of airflow

    Section 603.4.2 requires crimp joints for round and oval metal ducts to be lapped not less than 1 inch, with the male end of the duct extending into the adjoining duct in the direction of airflow so the joint does not catch debris or leak at the seam.

    Reference: 2018 International Mechanical Code (IMC), Section 603.4.2

  10. A non-self-supporting ladder with a working length of 16 feet is set against a roof edge to reach a rooftop unit. About how far from the wall should the foot of the ladder be placed?

    Answer: About 4 feet

    Under the ladder rule, the horizontal distance from the top support to the foot of a non-self-supporting ladder should be approximately one-quarter of the working length: 16 ft / 4 = 4 ft. 2 feet is too steep and unstable, 8 feet is half the length and too shallow, and 16 feet would lay the ladder flat.

    Reference: 29 CFR Part 1926 (OSHA construction standards), 29 CFR 1926.1053(b)(5)(i)

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.