Requirements at a glance
| Agency | State Plumbing Board of Louisiana (SPBLA); exam run by the Board in Baton Rouge and Shreveport |
|---|---|
| Experience | A current Louisiana natural gas fitter license, LSLBC Mechanical (Statewide) license or professional engineer license |
| Exam | Two written parts: 80 questions on the 2021 IFGC (3 hours) and 40 on business and law (2 hours) |
| Books | 2021 IFGC; NASCLA Louisiana Master Plumbers and Master Natural Gasfitters guide, 2nd Edition |
| Fees | $110 exam ($100 + $10 processing); license $190 active or $40 inactive |
Louisiana natural gas fitters, LSLBC Mechanical (Statewide) license holders or professional engineers applying for a master natural gas fitter license from SPBLA.
Official links
How to get licensed, step by step
Register as an apprentice
Everyone doing plumbing or gas fitting must register with SPBLA and work for a master company under direct supervision ($20; renew every December 31).
SPBLA: license types and exam information (opens in a new tab)
Apply for the exam
Send the notarized application with proof of hours and the fee at least 30 days before the exam date. Dates are on the SPBLA exam schedule.
SPBLA: exam applications (opens in a new tab)State Plumbing Board of Louisiana (SPBLA) (opens in a new tab)
Sit the exam
The Board mails your results, usually within 2 weeks. If you fail, it sends a retake form.
SPBLA: license types and exam information (opens in a new tab)
Get licensed
After you pass, return the initial license form and fee. Licenses renew every year before December 31 with continuing education.
SPBLA: license types and exam information (opens in a new tab)
How to prepare
- SPBLA publishes no topic outline or passing score, so our topic mix is an estimate from the reference books.
- Passing scores are valid for 90 days: return the initial license form and fee in time or you retake the whole exam. A single passed part is good for one year.
- Part II is business and law from the NASCLA guide, very different from the IFGC; study Louisiana contractor and plumbing law basics.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IFGC and the NASCLA Louisiana guide. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 International Fuel Gas Code (IFGC)Essential
The only code for the natural gas fitter exam; also used by HVACR and, in the 2018 edition, Mechanical Work.
ICC store (opens in a new tab)Read free (UpCodes): IFGC 2021 (opens in a new tab)
NASCLA Louisiana Master Plumbers and Master Natural Gasfitters Guide to Business, Law, and Project Management, 2nd EditionEssential
Master plumber Part III (40 questions).
NASCLA store (Louisiana master plumber and gas fitter guide) (opens in a new tab)
Official reference list (as published by the testing agency)
- International Fuel Gas Code (IFGC), 2021 Edition
- NASCLA Louisiana Master Plumbers and Master Natural Gasfitters Guide to Business, Law, and Project Management, 2nd Edition
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Part I: International Fuel Gas Code (2021) | 80 | |
| Part II: Business, Law and Project Management (NASCLA Louisiana guide) | 40 |
The parts are timed and scored separately, and you must pass each one. Our simulations score each part the same way and give you the combined time (300 minutes).
Exam day details
- Administered by State Plumbing Board of Louisiana (SPBLA).
- Fee: $110 to SPBLA ($100 exam fee plus $10 processing). The license fee is $190 (active) or $40 (inactive).
- Two written parts: 80 questions in 3 hours and 40 questions in 2 hours. If you pass one part and not the other, the passing score is good for one year.
- Eligibility: a current Louisiana natural gas fitter license, a current LSLBC Mechanical (Statewide) license, or a professional engineer license.
- Passing scores are only valid for 90 days: if you don't return the initial license form and fee within 90 days you forfeit your scores and retake the whole exam.
- Board-run exam (not PSI), given in Baton Rouge and Shreveport; the exam schedule is on spbla.com.
- Apply to the Board at least 30 days before the exam date, notarized, with the application fee by check or money order. Cancelling less than 30 days out forfeits the fee.
- Results are mailed, usually within 2 weeks. After a failure the Board sends a retake form.
Note: SPBLA publishes no topic outline or weights, and we could not confirm its passing score (secondary sources say 70%). The topic weights on this page are our estimate from the reference books.
Frequently asked questions
What's on the Louisiana master natural gas fitter exam?
Two written parts: Part I, 80 questions on the 2021 IFGC, and Part II, 40 questions on business and law from the NASCLA Louisiana guide.
Who can take it?
Holders of a current Louisiana natural gas fitter license, a current LSLBC Mechanical (Statewide) license or a professional engineer license.
How long is a passing score valid?
SPBLA prints a 90-day limit for the master natural gas fitter exam: send in the license form and fee within 90 days or retake the entire exam. A single passed part is good for one year.
Free questions with answers
Show all 10 free questions and answers
Under the 2021 IFGC, a house is piped in Schedule 40 steel with natural gas at 1,000 Btu per cubic foot, inlet pressure below 2 psi and a 0.5 inch w.c. pressure drop. The longest run from the meter to the most remote appliance is 80 feet. The appliances are a 100,000 Btu/h furnace, a 40,000 Btu/h water heater, a 65,000 Btu/h range and a 35,000 Btu/h dryer. Using the longest length method, what is the minimum size for the pipe section that serves all four appliances?
Answer: 1-1/4 inches
Total load = 100,000 + 40,000 + 65,000 + 35,000 = 240,000 Btu/h, and 240,000 / 1,000 = 240 cfh. The longest length method (Section 402.4.1) sizes every section from the 80 ft row of Table 402.4(2). At 80 ft, 1 inch carries only 220 cfh, which is short, while 1-1/4 inch carries 452 cfh. A 1 inch pipe is the tempting answer because it is close to 240.
Reference: 2021 International Fuel Gas Code, Table 402.4(2) and Section 402.4.1
Under the 2021 IFGC, Schedule 40 steel pipe carries natural gas at a 2.0 psi inlet pressure with a 1.0 psi design pressure drop. A line regulator at each appliance serves a total load of 1,500,000 Btu/h at 1,000 Btu per cubic foot, and the longest length is 100 feet. What is the minimum pipe size for the main?
Answer: 1 inch
1,500,000 / 1,000 = 1,500 cfh. Table 402.4(5) at 100 ft gives 462 cfh for 1/2 inch, 934 cfh for 3/4 inch, 1,710 cfh for 1 inch and 3,510 cfh for 1-1/4 inch. The smallest size that carries 1,500 cfh is 1 inch.
Reference: 2021 International Fuel Gas Code, Table 402.4(5)
A gas supplier delivers natural gas to a commercial kitchen at an initial supply pressure of 9 inches w.c., and the designer allows a 3.0 inch w.c. pressure drop. The longest length is 60 feet and the load is 1,250 cfh of natural gas. Using Schedule 40 steel pipe under the 2021 IFGC, what is the minimum pipe size?
Answer: 1-1/4 inches
Table 402.4(3) is the Schedule 40 table for under 2 psi with a 3.0 inch w.c. drop, intended for an initial supply pressure of 8.0 inches w.c. or greater. At 60 ft it lists 678 cfh for 1 inch and 1,390 cfh for 1-1/4 inch, so 1-1/4 inch is the smallest size that carries 1,250 cfh.
Reference: 2021 International Fuel Gas Code, Table 402.4(3)
Natural gas at 1,000 Btu per cubic foot feeds a 90,000 Btu/h appliance through 30 feet of Type L copper tubing. The inlet is under 2 psi with a 0.5 inch w.c. drop. Under the 2021 IFGC, which is the smallest nominal K and L tube size that will carry the load?
Answer: 5/8 inch
Load = 90,000 / 1,000 = 90 cfh. Table 402.4(9) at 30 ft gives 30 cfh for 3/8 inch, 61 cfh for 1/2 inch, 107 cfh for 5/8 inch and 152 cfh for 3/4 inch. The 1/2 inch tube falls short and 5/8 inch is the smallest that works.
Reference: 2021 International Fuel Gas Code, Table 402.4(9)
Undiluted propane vapor at 2,500 Btu per cubic foot is supplied at 11 inches w.c. with a 0.5 inch w.c. drop to appliances totaling 400,000 Btu/h. The longest length of Schedule 40 steel pipe is 50 feet. Under Table 402.4(28) of the 2021 IFGC, what is the minimum pipe size?
Answer: 1 inch
Table 402.4(28), for undiluted propane between the second-stage regulator and the appliance, lists capacity in thousands of Btu per hour, so the 400,000 Btu/h load is read directly as 400 (no conversion to cfh). At 50 ft the table gives 122 for 1/2 inch, 255 for 3/4 inch and 480 for 1 inch, so 1 inch is the smallest size that carries 400. Converting to 160 cfh (400,000 / 2,500) and picking 3/4 inch is the common mistake because the table is not in cfh.
Reference: 2021 International Fuel Gas Code, Table 402.4(28)
Under R.S. 37:1367(J), who may do the work of a gas fitter in Louisiana without a board-issued license?
Answer: A person working on his own residence
R.S. 37:1367(J)(1) bars anyone from doing gas fitter or master gas fitter work without a board license, and (J)(2) exempts work performed by persons on their own residences. Supervised apprentices must be under a gas fitter.
Reference: Louisiana Plumbing Law (La. R.S. 37:1361 et seq.), R.S. 37:1367(J)
Under R.S. 37:1377(J), which description fits a master gas fitter?
Answer: A person qualified to plan and lay out gas piping and supervise installation
R.S. 37:1377(J) defines a master gas fitter as a natural person with the skills and qualifications to plan and lay out the details for installing and supervising natural gas piping systems and tanks annexed to real property, excluding LPG Commission licensees.
Reference: Louisiana Plumbing Law (La. R.S. 37:1361 et seq.), R.S. 37:1377(J)
A master gas fitter dies. Under LAC 46:LV §301.Q, how long may the employing entity keep operating on his license, and what must it do?
Answer: Up to six months; apply in writing within 30 days of the death
§301.Q lets the employing entity operate on the deceased master gas fitter's license for up to six months after the death. The grace period must be applied for in writing within 30 days of the death, and the entity must follow all other board regulations meanwhile. The board may require proof of death.
Reference: Louisiana Administrative Code Title 46, Part LV (State Plumbing Board rules, May 2023), §301.Q
A professional engineer wants to take the master gas fitter exam. Under LAC 46:LV §308.A.1, what additional requirement applies?
Answer: Five years of experience in the art of gas fitting
§308.A.1 says a registered or certified professional engineer must further have experience in the art of gas fitting, as defined in R.S. 37:1377(K), for a period of five years.
Reference: Louisiana Administrative Code Title 46, Part LV (State Plumbing Board rules, May 2023), §308.A.1
Under LAC 46:LV §308.C, what happens to an applicant's fee if he fails to report for the exam?
Answer: It is forfeited, unless the board finds good cause
§308.C says failure to report for examination results in forfeiture of the applicant's fee. The board may reverse the forfeiture on a showing of good cause.
Reference: Louisiana Administrative Code Title 46, Part LV (State Plumbing Board rules, May 2023), §308.C
Sources
- State Plumbing Board of Louisiana (SPBLA) (opens in a new tab)
- SPBLA: license types and exam information (opens in a new tab)
- Louisiana State Uniform Construction Code Council (adopted codes) (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.