Requirements at a glance
| Agency | State Plumbing Board of Louisiana (SPBLA); exam run by the Board in Baton Rouge and Shreveport |
|---|---|
| Experience | Two years of gas fitting under a natural gas fitter or master (4,000 hours for an out-of-state license); reciprocity only with Arkansas and Texas |
| Exam | 80 written questions in 3 hours plus a 30-minute screw pipe practical |
| Books | 2021 International Fuel Gas Code |
| Fees | $135 exam; license $50 |
Registered apprentices or Louisiana plumbers with two years of gas fitting work applying for a journeyman natural gas fitter license from SPBLA.
Official links
How to get licensed, step by step
Register as an apprentice
Everyone doing plumbing or gas fitting must register with SPBLA and work for a master company under direct supervision ($20; renew every December 31).
SPBLA: license types and exam information (opens in a new tab)
Apply for the exam
Send the notarized application with proof of hours and the fee at least 30 days before the exam date. Dates are on the SPBLA exam schedule.
SPBLA: exam applications (opens in a new tab)State Plumbing Board of Louisiana (SPBLA) (opens in a new tab)
Sit the exam
The Board mails your results, usually within 2 weeks. If you fail, it sends a retake form.
SPBLA: license types and exam information (opens in a new tab)
Get licensed
After you pass, return the initial license form and fee. Licenses renew every year before December 31 with continuing education.
SPBLA: license types and exam information (opens in a new tab)
How to prepare
- SPBLA publishes no topic outline or passing score, so our topic mix is an estimate from the reference books.
- Everything comes from the 2021 IFGC: tab Chapter 4 (gas piping sizing tables), Chapter 5 (venting) and Chapter 3 (general regulations and combustion air).
- Practice sizing pipe from the Chapter 4 tables, including longest-length method, since sizing is a large share of any gas exam.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IFGC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 International Fuel Gas Code (IFGC)Essential
The only code for the natural gas fitter exam; also used by HVACR and, in the 2018 edition, Mechanical Work.
ICC store (opens in a new tab)Read free (UpCodes): IFGC 2021 (opens in a new tab)
Official reference list (as published by the testing agency)
- International Fuel Gas Code (IFGC), 2021 Edition
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Administration and General Regulations | 8 | |
| General Regulations and Appliance Location | 10 | |
| Gas Piping Installations and Sizing | 24 | |
| Chimneys, Vents and Combustion Air | 14 | |
| Specific Appliances | 16 | |
| Testing, Purging and Safety | 8 |
Exam day details
- Administered by State Plumbing Board of Louisiana (SPBLA).
- Fee: $135 to SPBLA. The license fee ($50) is separate.
- 80 written questions in 3 hours, then a 30-minute hands-on screw pipe project.
- Eligibility: two years of gas fitting under a natural gas fitter or master (about 1.5 years for most indentured and 2 for unindentured apprentices), or a current Louisiana plumber license with that gas fitting time. Hours are proven with payroll records or W-2s from a licensed master company.
- Board-run exam (not PSI), given in Baton Rouge and Shreveport; the exam schedule is on spbla.com.
- Apply to the Board at least 30 days before the exam date, notarized, with the application fee by check or money order. Cancelling less than 30 days out forfeits the fee.
- Results are mailed, usually within 2 weeks. After a failure the Board sends a retake form.
- You must be a registered apprentice (registration $20) working under a licensed journeyman or master first.
Note: SPBLA publishes no topic outline or weights, and we could not confirm its passing score (secondary sources say 70%). The topic weights on this page are our estimate from the reference books.
Frequently asked questions
What's on the Louisiana journeyman natural gas fitter exam?
80 written questions from the 2021 IFGC plus a 30-minute screw pipe practical. SPBLA does not publish topic weights.
How much experience do I need?
Two years of gas fitting training under a natural gas fitter or master; most indentured apprentices qualify at about 1.5 years.
What does the exam cost?
$135 to SPBLA, with a $50 license fee after you pass.
Free questions with answers
Show all 10 free questions and answers
Under the 2021 IFGC, a permit application was filed but never pursued and no permit was issued. After how many days is the application deemed abandoned, unless the code official grants an extension?
Answer: 180 days
Section 106.3.1 deems an application abandoned 180 days after filing unless it has been pursued in good faith or a permit has been issued. The code official may grant one or more written extensions of up to 180 days each for justifiable cause.
Reference: 2021 International Fuel Gas Code, Section 106.3.1
Under the 2021 IFGC, a new natural gas system has a proposed maximum working pressure of 5 psig. What is the minimum pressure for the required pressure test?
Answer: 7.5 psig
Section 406.4.1 sets the test pressure at not less than 1-1/2 times the maximum working pressure, and never less than 3 psig. 1.5 x 5 psig = 7.5 psig, which is above the 3 psig floor. Testing at 5 psig is only the working pressure, and 3 psig is the floor used only for low-pressure systems.
Reference: 2021 International Fuel Gas Code, Section 406.4.1
A fitter is joining Schedule 10 stainless steel gas pipe under the 2021 IFGC. Which joining method does Section 403.9.1 permit for pipe lighter than Schedule 40?
Answer: Welding, brazing, flanges or listed press-connect fittings
Section 403.9.1 allows Schedule 40 and heavier pipe to be threaded, flanged, brazed, welded or joined with listed press-connect fittings, but pipe lighter than Schedule 40 must be connected with press-connect fittings, flanges, brazing or welding. Thin-wall pipe cannot be threaded because the cut threads leave too little wall.
Reference: 2021 International Fuel Gas Code, Section 403.9.1
Under the 2021 IFGC, copper and copper alloy tubing must not be used for fuel gas containing more than what average amount of hydrogen sulfide?
Answer: 0.3 grain per 100 standard cubic feet of gas
Sections 403.3.3 and 403.4.3 prohibit copper and copper alloy pipe or tubing where the gas contains more than an average of 0.3 grain of hydrogen sulfide per 100 standard cubic feet. Hydrogen sulfide attacks copper and causes corrosion that can flake and plug controls.
Reference: 2021 International Fuel Gas Code, Section 403.4.3
Under the 2021 IFGC, an appliance with an ignition source is installed in a private garage in the usual way. What is the minimum height of the ignition source above the garage floor?
Answer: 18 inches
Section 305.3 requires appliances with an ignition source to be elevated so that the source of ignition is at least 18 inches above the floor in hazardous locations and in public, private, repair and parking garages and motor fuel-dispensing facilities. This keeps the flame above heavier-than-air gas vapors that settle low.
Reference: 2021 International Fuel Gas Code, Section 305.3
A gas appliance in a public garage may be hit by vehicles. Under 2021 IFGC Section 305.4, what is the minimum installation height above the floor, absent the exception for protected appliances?
Answer: 8 feet
Section 305.4 requires appliances in public garages, motor fuel-dispensing facilities, repair garages and other areas frequented by motor vehicles to be at least 8 feet above the floor. Private garages in Section 305.5 use a 6 foot clearance. The 18 inch figure in Section 305.3 is for ignition source height and is separate.
Reference: 2021 International Fuel Gas Code, Section 305.4
A utility room holds a 100,000 Btu/h furnace and a 40,000 Btu/h water heater, and combustion air is to come from inside the building by the 2021 IFGC standard method. What is the minimum required room volume?
Answer: 7,000 cubic feet
Section 304.5.1 requires 50 cubic feet per 1,000 Btu/h of appliance input, and the volumes of all appliances in the space are added. Total input = 100,000 + 40,000 = 140,000 Btu/h, and 140,000 / 1,000 x 50 = 7,000 cubic feet. The 14,000 figure uses 100 cubic feet per 1,000 Btu/h, and 2,800 uses 20.
Reference: 2021 International Fuel Gas Code, Section 304.5.1
A closet holds a 100,000 Btu/h furnace and a 40,000 Btu/h water heater with all combustion air from outdoors through two openings, each directly communicating with the outdoors. What is the minimum free area of EACH opening under the 2021 IFGC?
Answer: 35 square inches
Section 304.6.1 requires two permanent openings, one within 12 inches of the top and one within 12 inches of the bottom of the enclosure. Where directly to the outdoors or by vertical ducts, each needs 1 square inch per 4,000 Btu/h of total input. 140,000 / 4,000 = 35 square inches each. 70 square inches is the horizontal duct figure at 1 per 2,000 Btu/h.
Reference: 2021 International Fuel Gas Code, Section 304.6.1
Under the 2021 IFGC, what is the maximum input rating permitted for an unvented room heater?
Answer: 40,000 Btu/h
Section 621.3 states that unvented room heaters shall not have an input rating in excess of 40,000 Btu/h. The 10,000 Btu/h figure is the lower limit that Section 303.3 uses for a single wall-mounted unvented heater in a bedroom, and 6,000 Btu/h is the bathroom limit.
Reference: 2021 International Fuel Gas Code, Section 621.3
Under 2021 IFGC Section 609.2, in which location may a floor furnace NOT be installed?
Answer: In the floor of a stairway landing
Section 609.2 prohibits floor furnaces in the floor of any doorway, stairway landing, aisle or passageway, or exitway, and in concrete floor construction built on grade. Doors or drapes may not be nearer than 12 inches to the register, the thermostat may be in an adjacent permanently open space, and the remaining sides may be 6 inches from a wall.
Reference: 2021 International Fuel Gas Code, Section 609.2
Sources
- State Plumbing Board of Louisiana (SPBLA) (opens in a new tab)
- SPBLA: license types and exam information (opens in a new tab)
- Louisiana State Uniform Construction Code Council (adopted codes) (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.