Requirements at a glance
| Agency | Your Kansas city or county licenses you; the International Code Council (ICC) gives the exam through Pearson VUE. There is no statewide license |
|---|---|
| Experience | Set by your city or county. Johnson County (license types A, B, C, DR) sets no years-of-experience rule: the company's qualifying individual shows a passing ICC exam or the required education and takes 8 hours of continuing education per license class each year, and the company carries general liability and workers' compensation insurance |
| Exam | KGC: 80 questions, 4 hours, 75% |
| Books allowed | 2018 International Residential Code and the Concrete Manual (2021 IBC/ACI 318-19 or 2015 IBC/ACI 318-14 edition) |
| Fees | $115 per ICC exam (national T-series exams are $120), plus your city or county's certificate or license fees |
Residential builders and remodelers applying for a Johnson County Type C (residential building) contractor license, or for a similar license from a Kansas city or county that accepts the ICC standard exam.
Official links
How to get licensed, step by step
Ask your city or county which exam it accepts
Kansas law lets each jurisdiction name the standard examinations it accepts as proof of competency. Confirm the exam and the experience rules before you pay.
Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)Kansas statute K.S.A. 12-1525 (standard examinations) (opens in a new tab)
Register for the residential building contractor exam (KGC) with ICC and Pearson VUE
Create an ICC account, pick the Kansas standard exam from the Exam Catalog and schedule a Pearson VUE appointment. If you fail, wait 10 days to retake.
Schedule with Pearson VUE (ICC exams) (opens in a new tab)ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)
Pass at 75% with your books
The exam is open book with four-option multiple choice and no penalty for guessing. Bring only the approved references.
ICC: State of Kansas exam bulletin (PDF) (opens in a new tab)
Apply to your city or county
Send your passing score and proof of experience to the jurisdiction, with its fee. It issues the certificate or license and sets renewal rules.
Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)Johnson County Contractor Licensing: exam information (opens in a new tab)
How to prepare
- Study the edition the exam is built on: the 2017 NEC for electrical and the 2018 IPC, IMC and IFGC for plumbing and mechanical. Your city's adopted code can be newer.
- The exam is open book, but there is not time to look up every answer. Tab your books by chapter and table before exam day.
- The 2014 NEC / 2015 I-Code Kansas exams end December 1, 2026. If your jurisdiction wants a 2021-based exam, ask about the national ICC T-series instead.
- Structural systems (46%) is almost half the exam: footings, foundations, floors, wall framing, roof construction and stairs in IRC Chapters 4 through 8.
- Planning and life safety (24%) draws on IRC Chapter 3: R301 design criteria, R302 fire-resistant construction, R310 emergency escape, R311 means of egress and R314/R315 alarms.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 International Residential Code (IRC)Essential
Allowed in the exam room. The code for one- and two-family dwellings: design criteria, foundations, framing, roofs and life safety.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
Concrete Manual (2021 IBC/ACI 318-19 or 2015 IBC/ACI 318-14 edition)
Allowed in the exam room. Either edition of the ICC Concrete Manual is on the reference list; bring the one you are comfortable with.
Official reference list (as published by the testing agency)
- 2018 International Residential Code (IRC) (allowed in the exam room)
- Concrete Manual (CM) based on the 2021 IBC and ACI 318-19, or the Concrete Manual based on the 2015 IBC and ACI 318-14 (allowed in the exam room)
What's on the exam
Official content outline from International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Permits and General Regulations | 18 | |
| Building Planning and Life Safety | 24 | |
| Structural Systems | 46 | |
| Building Envelope | 12 |
The outline totals 100; the other items on the 80-question exam are unscored or unassigned.
Exam day details
- Administered by International Code Council (ICC), delivered by Pearson VUE, for Kansas cities and counties.
- Fee: $115 to ICC through Pearson VUE per exam. Your city or county's license fees are separate.
- 80 multiple-choice questions in 4 hours; 75% to pass.
- Open book: bring the approved references. Questions are four-option multiple choice with no penalty for guessing; 75% to pass.
- Kansas has no statewide electrician, plumber or mechanical license. ICC only tests; the city or county where you want to work sponsors you and issues the license.
- If you fail, wait 10 days to retake.
- The 2014 NEC / 2015 I-Code exams stop being offered December 1, 2026. These Kansas standard exams are based on the 2017 NEC and 2018 I-Codes; the national T-series exams cover the 2020 NEC and 2021 I-Codes.
Frequently asked questions
What's on the Kansas residential building contractor exam?
80 questions by weight: permits and general regulations 18%, building planning and life safety 24%, structural systems 46% and building envelope 12%.
Which code books does it use?
The 2018 International Residential Code, plus the Concrete Manual (either the 2021 IBC/ACI 318-19 edition or the 2015 IBC/ACI 318-14 edition).
Which jurisdictions accept it?
Johnson County recognizes the KGC exam for its C (residential building) license. Other cities and counties set their own rules, so confirm where you will work.
Free questions with answers
Show all 10 free questions and answers
A homeowner wants to build a one-story detached storage shed with a floor area of 192 square feet (12 ft by 16 ft) in the back yard. Under the 2018 IRC administrative provisions, is a building permit required for the shed itself?
Answer: No, a one-story detached accessory structure of 200 square feet or less is exempt
R105.2 lists one-story detached accessory structures with a floor area not over 200 square feet as exempt from permit. The 192 square foot shed qualifies. Exemption from a permit never excuses violating other provisions of the code, so setbacks and zoning still apply. The 120 square foot figure comes from other codes, not the 2018 IRC.
Reference: 2018 International Residential Code, R105.2 Work Exempt From Permit
A freestanding wood deck is 180 square feet in area and 36 inches above grade at its highest point. It is not attached to the dwelling and does not serve the required exit door. Under R105.2, which statement is correct?
Answer: It needs a permit because it is more than 30 inches above grade
The R105.2 deck exemption requires all conditions together: not more than 200 square feet, not more than 30 inches above grade at any point, not attached to a dwelling, and not serving the exit door required by R311.4. At 36 inches the deck fails the height condition, so a permit is required even though the area and attachment conditions are met.
Reference: 2018 International Residential Code, R105.2 Work Exempt From Permit
A permit application was filed, but the applicant never answered the plan reviewer's comments. Under R105.3.2, after how long is the application deemed abandoned unless it has been pursued in good faith or a permit has been issued?
Answer: 180 days after filing
R105.3.2 says an application is deemed abandoned 180 days after filing unless pursued in good faith or a permit has been issued. The building official may grant one or more extensions of up to 180 days each when requested in writing with justifiable cause.
Reference: 2018 International Residential Code, R105.3.2 Time Limitation of Application
A basement bedroom's egress window is served by a window well that is 36 inches wide, projects 36 inches from the wall and is 52 inches deep from the top of the well to the bottom. What does R310.2.3 require for this well?
Answer: A permanently affixed ladder or steps, because the well is deeper than 44 inches
The well is 36 in x 36 in = 1,296 sq in = 9 sq ft, which meets the minimum horizontal area of 9 sq ft with at least 36 in projection and width (R310.2.3). A vertical depth greater than 44 in requires a permanently affixed ladder or steps usable with the window fully open (R310.2.3.1). The 72-inch figure is invented, and the 12 sq ft figure is not in the IRC.
Reference: 2018 International Residential Code, R310.2.3.1 Ladder and Steps
What is the minimum clear width required for the egress door of a dwelling unit, measured between the face of the door and the stop with the door open 90 degrees?
Answer: 32 inches
R311.2 requires at least one side-hinged egress door per dwelling unit with a clear width of not less than 32 inches and a clear height of not less than 78 inches. Other doors in the dwelling are not required to meet these minimums.
Reference: 2018 International Residential Code, R311.2 Egress Door
A wood deck floor is 42 inches above the ground at its edge, with a stair of 5 risers. Under R312, what is the minimum height of the guard on the deck surface, and what is the largest sphere that must not pass through any opening in the guard?
Answer: 36 inches high; a 4-inch sphere
Guards are required on open-sided walking surfaces more than 30 inches above the floor or grade below (R312.1.1). Guard height at porches and decks is at least 36 inches (R312.1.2) and openings must not pass a 4-inch sphere (R312.1.3). The 34 inch height and 4 3/8-inch sphere apply to the open side of stairs only; 42 inches is a commercial height.
Reference: 2018 International Residential Code, R312.1.2 Height
A 6-foot-long wood sill plate section sits on a concrete foundation wall and is anchored with 1/2-inch-diameter anchor bolts. What is the minimum number of anchor bolts for this plate section, and how close to each end must the end bolts be, according to R403.1.6?
Answer: Two bolts, each within 12 inches but not less than 3 1/2 inches from its end of the plate
R403.1.6 requires anchor bolts of at least 1/2 inch diameter at not more than 6 feet on center, with not fewer than two bolts per plate section and one bolt located not more than 12 inches or less than seven bolt diameters from each end of the plate section. Seven bolt diameters = 7 x 1/2 in = 3 1/2 in. On a 6-foot section the two end bolts are at most 72 - 7 = 65 inches apart, inside the 6-foot spacing limit, so two bolts suffice. Bolts must extend at least 7 inches into the concrete and sit in the middle third of the plate width.
Reference: 2018 International Residential Code, R403.1.6 Foundation Anchorage
A garage floor slab will be poured in a location the plans classify as having severe weathering potential. According to Table R402.2, what are the minimum specified compressive strength and the air-entrainment requirement?
Answer: 3,500 psi with total air content of 5 to 7 percent
Table R402.2 lists porches, carport slabs, steps exposed to weather and garage floor slabs at 3,500 psi (28 days) for severe weathering potential, and requires air entrainment with total air content of not less than 5 nor more than 7 percent. The 3,000 psi value is the moderate-weathering figure; 2,500 psi applies to negligible weathering. A steel-troweled garage floor may drop to 3 percent air only if strength is at least 4,000 psi.
Reference: 2018 International Residential Code, Table R402.2 Minimum Specified Compressive Strength of Concrete
What is the minimum roof slope on which asphalt shingles may be installed, and what extra is required on slopes from that minimum up to 4:12, under R905.2.2?
Answer: 2:12 slope; double underlayment application
R905.2.2 permits asphalt shingles only on slopes of 2 units vertical in 12 horizontal (17 percent) or greater. On slopes from 2:12 up to 4:12 (33 percent), double underlayment application is required per R905.1.1. Slopes below 2:12 need a different roof covering such as a membrane system.
Reference: 2018 International Residential Code, R905.2.2 Slope
A roofer is installing asphalt shingles over 15/32-inch (roughly 1/2-inch) OSB roof sheathing with galvanized 12-gage roofing nails with 3/8-inch heads. What does R905.2.5 require for nail length?
Answer: Long enough to penetrate through the sheathing, because it is under 3/4 inch thick
R905.2.5 requires roofing nails of minimum 12-gage shank with a 3/8-inch minimum head, long enough to penetrate through the roofing materials and at least 3/4 inch into the roof sheathing. Where the sheathing is less than 3/4 inch thick, the fasteners must penetrate through the sheathing. A 15/32-inch panel is under 3/4 inch.
Reference: 2018 International Residential Code, R905.2.5 Fasteners
Sources
- ICC: State of Kansas Contractor/Trades Examination Information Bulletin (10/12/2026) (opens in a new tab)
- Pearson VUE: ICC exams (opens in a new tab)
- Sedgwick County MABCD: master and journeyman trade certificates (opens in a new tab)
- Johnson County Contractor Licensing: exam information (opens in a new tab)
Questions last verified November 5, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.