Requirements at a glance
| Agency | Iowa Electrical Examining Board (Dept. of Inspections, Appeals, & Licensing); exam by PSI |
|---|---|
| Experience | 6,000 hours as an apprentice electrician (you may test after 5,000), or a registered residential apprenticeship; other routes combine trade school or unclassified-person hours (481 IAC 401.2(8)) |
| Exam | 50 scored questions, 120 minutes, open book; 70% to pass |
| Books allowed | Open book: NFPA 70 (2023) or NEC Handbook 2023, permanent tabs only; Ugly's not allowed |
| Fees | $87 to PSI per exam (valid 6 months); license fee due after you pass |
Electricians applying to the Iowa Electrical Examining Board for a residential electrician license, which covers residential installations (a residence of no more than four living units in one building). You need 6,000 hours as an apprentice electrician (you may test after 5,000), a registered residential apprenticeship, 4,000 supervised hours plus a year of approved trade school, or 8,000 hours as an unclassified person with 2,000 in residential wiring (Iowa Code 103.1, 481 IAC 401.2(8)).
Official links
How to get licensed, step by step
Apply to the Board
Send the license application and a Testing Sponsorship Request to the Electrical Examining Board. No license application is needed if you already hold one.
Get your authorization letter
When the Board approves you it sends an authorization to test, valid for two exam attempts or six months.
Pay and schedule with PSI
Register with PSI, pay the $87 fee and pick one of the four Iowa centers or any other PSI site. Cancel at least 2 days ahead to keep your fee.
Pass and get licensed
You need 70%. After you pass, contact the Board for instructions and pay the license fee.
How to prepare
- Iowa adopted the 2023 NEC effective July 1, 2025 (DIAL says unamended). The PSI exam references the 2023 NEC; bring NFPA 70 or the NEC Handbook, 2023. Ugly's is not allowed.
- The PSI outline covers NEC topics only, with no Iowa-law section, so practice NEC lookups and trade math rather than state statutes.
- Allowed: highlighting, underlining and permanent tabs. Not allowed: writing in the book, sticky notes or loose papers. PSI also gives you an on-screen calculator.
- Wiring methods and materials is a quarter of the residential exam. Drill dwelling branch circuits, receptacles, GFCI and AFCI rules and service calculations.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 edition (or the 2023 NEC Handbook)Essential
The only reference allowed in the PSI exam room. Iowa adopted the 2023 NEC effective July 1, 2025. Ugly's Electrical References is explicitly not allowed.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 edition, or the 2023 NEC Handbook (allowed in the exam room; Ugly's is not)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 10 | |
| Wiring and Protection | 25 | |
| Wiring Methods and Materials | 25 | |
| Equipment for General Use | 20 | |
| Special Occupancies | 5 | |
| Special Equipment | 5 | |
| Special Conditions | 5 | |
| Communication Systems | 5 |
The outline totals 100; the other items on the 50-question exam are unscored or unassigned.
Exam day details
- Administered by PSI Services for the Iowa Electrical Examining Board.
- Fee: $87 to PSI per exam; not refundable or transferable and valid for 6 months. The Board's license application and license fees are separate.
- 50 scored questions plus 5 unscored items in 120 minutes (plus 15 minutes for the unscored items); 70% correct to pass.
- Open book: bring your own NFPA 70 (2023) or the 2023 NEC Handbook. Ugly's Electrical References is NOT allowed. You may highlight, underline and index with permanent tabs, but not write in the book; sticky notes are removed.
- PSI also gives you an on-screen calculator; you may bring a silent, battery-operated, non-programmable calculator with no paper tape.
- Send the Board your license application and a Testing Sponsorship Request. When it approves you, you get an authorization letter valid for 2 exam attempts or 6 months; then you pay and schedule with PSI. After two failures, contact the Board for a new letter.
- PSI tests at four Iowa centers and any other PSI site. The license fee is due after you pass.
Frequently asked questions
What's on the Iowa residential electrician exam?
50 scored questions: wiring and protection 25, wiring methods and materials 25, equipment for general use 20, general electrical knowledge 10, special occupancies 5, special equipment 5, special conditions 5 and communication systems 5.
Is the exam open book?
Yes, with NFPA 70 (2023) or the 2023 NEC Handbook. Ugly's is not allowed.
How much does the exam cost?
$87 to PSI, valid for six months and not refundable. The Board's license fee is due after you pass.
Free questions with answers
Show all 10 free questions and answers
Two identical 120-volt, 1,000-watt resistance heating elements are connected in series across a 240-volt supply. Assuming each element's resistance stays constant, what total power do the two elements produce?
Answer: About 2,000 watts
Each element has R = E squared / P = 120 x 120 / 1,000 = 14.4 ohms, so the series string is 28.8 ohms. Total power at 240 V is 240 x 240 / 28.8 = 2,000 W: each element sees 120 V and makes its rated 1,000 W. 4,000 W is what one element alone would produce across 240 V, and 1,000 W counts only one element.
Reference: NFPA 70, National Electrical Code, 2023, Basic electricity theory: power formula (P = E squared / R)
A kitchen countertop receptacle outlet in a dwelling is to be mounted on the wall above the counter. Under 210.52(C)(3), how far above the countertop may the receptacle be installed at most?
Answer: 20 inches
Receptacle outlets serving a countertop must be on or above, but not more than 500 mm (20 in.) above, the countertop or work surface (210.52(C)(3)). Outlets higher than that do not count toward the required countertop receptacles, so 30 or 48 in. fails.
Reference: NFPA 70, National Electrical Code, 2023, 210.52(C)(3)
Type NM cable in exposed work passes up through a wood floor in a dwelling garage workshop. What does 334.15(B) require at the floor penetration?
Answer: The cable must be enclosed in conduit or tubing extending at least 6 inches above the floor
Section 334.15(B) requires exposed NM cable to be protected from physical damage where necessary, and where it passes through a floor it must be enclosed in rigid metal conduit, IMC, EMT, Schedule 80 PVC, RTRC-XW or other approved means extending at least 150 mm (6 in.) above the floor, with a bushing or adapter to protect against abrasion.
Reference: NFPA 70, National Electrical Code, 2023, 334.15(B)
What is the minimum bending radius for the inner edge of a bend in Type NM cable under 334.24?
Answer: Five times the diameter of the cable
Section 334.24 requires that the radius of the curve of the inner edge of any bend in Type NM or NMC cable, during or after installation, be not less than five times the diameter of the cable. For flat cable, the major dimension is used as the diameter, so tight bends at a box fail the rule.
Reference: NFPA 70, National Electrical Code, 2023, 334.24
A homeowner's detached garage has electric power and a 15-ampere, 125-volt nonlocking receptacle for a workbench. Under 406.12, what type of receptacle is required?
Answer: A listed tamper-resistant receptacle
Section 406.12 requires 15- and 20-ampere nonlocking receptacles in all dwelling units, including their attached and detached garages and accessory buildings, to be listed tamper-resistant. The rule is not limited to rooms covered by 210.52, and weather-resistant listing is a separate requirement for damp and wet locations.
Reference: NFPA 70, National Electrical Code, 2023, 406.12
Which type of luminaire is not permitted in a clothes closet under 410.16(C)?
Answer: A pendant luminaire or lampholder
Section 410.16(C) prohibits incandescent luminaires with open or partially enclosed lamps and pendant luminaires or lampholders in clothes closets. Section 410.16(B) permits enclosed-source incandescent and LED types, fluorescent types, and LED luminaires identified for the storage space.
Reference: NFPA 70, National Electrical Code, 2023, 410.16(C)
A dwelling under construction has temporary power with receptacles for tools and a separate branch circuit for work lights. Under 590.4(D)(1), how must the construction-site receptacles be supplied?
Answer: Not on a circuit that supplies temporary lighting
Section 590.4(D)(1) requires receptacles on construction sites to be the grounding type and requires branch circuits to include a separate equipment grounding conductor unless in a qualifying metal raceway or cable. It also says the receptacles must not be on any branch circuit that supplies temporary lighting, so a tool fault does not leave workers in the dark.
Reference: NFPA 70, National Electrical Code, 2023, 590.4(D)(1)
A permanently installed residential swimming pool has a pump motor that is supplied through a receptacle. Under 680.22(A)(2), how far from the inside walls of the pool must that receptacle be?
Answer: At least 6 feet, with GFCI protection
Section 680.22(A)(2) requires receptacles that supply water-pump motors or other loads directly related to the circulation and sanitation system to be at least 1.83 m (6 ft) from the inside walls of the pool, of the grounding type and with GFCI protection. The 20 ft figure is the GFCI zone in 680.22(A)(4).
Reference: NFPA 70, National Electrical Code, 2023, 680.22(A)(2)
A 12-kW portable generator is connected to a dwelling through a flanged inlet on the outside wall. Under 702.12(B), what is required for the disconnecting means?
Answer: None, since the inlet is outdoors and the generator is 15 kW or less
Section 702.12(B) says that for a portable generator of 15 kW or less connected using a flanged inlet or other cord-and-plug connection, a disconnecting means is not required where ungrounded conductors serve or pass through a building, provided the inlet is located outside the building. Transfer equipment is still required by 702.5.
Reference: NFPA 70, National Electrical Code, 2023, 702.12(B)
If an aluminum busbar is used instead of an intersystem bonding termination device under 250.94(B), what are its minimum dimensions?
Answer: 1/4 inch thick by 2 inches wide, long enough for three terminations
Under 250.94(B), the busbar must be at least 6 mm thick by 50 mm wide (1/4 in. by 2 in.), of a length to accommodate at least three communications terminations in addition to other connections, securely fastened in an accessible location with listed connectors. Aluminum busbars must also comply with 250.64(A).
Reference: NFPA 70, National Electrical Code, 2023, 250.94(B)
Sources
- PSI: Iowa Electrical Examining Board Candidate Information Bulletin (updated 9/19/2025) (opens in a new tab)
- Iowa Electrical Examining Board (opens in a new tab)
- Iowa DIAL: electrical permits and inspections (adopted NEC) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.