Requirements at a glance
| Agency | Iowa Electrical Examining Board (Dept. of Inspections, Appeals, & Licensing); exam by PSI |
|---|---|
| Experience | A current residential or journeyman electrician license plus 2,000 hours of verified experience in it (481 IAC 401.2(5)) |
| Exam | 60 scored questions, 180 minutes, open book; 70% to pass |
| Books allowed | Open book: NFPA 70 (2023) or NEC Handbook 2023, permanent tabs only; Ugly's not allowed |
| Fees | $87 to PSI per exam (valid 6 months); license fee due after you pass |
Residential or journeyman electricians with 2,000 hours of verified experience in that license, applying to the Iowa Electrical Examining Board for a residential master license to direct residential installations (a residence of no more than four living units in one building) (Iowa Code 103.1, 481 IAC 401.2(5)).
Official links
How to get licensed, step by step
Apply to the Board
Send the license application and a Testing Sponsorship Request to the Electrical Examining Board. No license application is needed if you already hold one.
Get your authorization letter
When the Board approves you it sends an authorization to test, valid for two exam attempts or six months.
Pay and schedule with PSI
Register with PSI, pay the $87 fee and pick one of the four Iowa centers or any other PSI site. Cancel at least 2 days ahead to keep your fee.
Pass and get licensed
You need 70%. After you pass, contact the Board for instructions and pay the license fee.
How to prepare
- Iowa adopted the 2023 NEC effective July 1, 2025 (DIAL says unamended). The PSI exam references the 2023 NEC; bring NFPA 70 or the NEC Handbook, 2023. Ugly's is not allowed.
- The PSI outline covers NEC topics only, with no Iowa-law section, so practice NEC lookups and trade math rather than state statutes.
- Allowed: highlighting, underlining and permanent tabs. Not allowed: writing in the book, sticky notes or loose papers. PSI also gives you an on-screen calculator.
- Same outline as the residential exam with more questions and time. Drill dwelling branch circuits, receptacles, GFCI and AFCI rules and service calculations.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 edition (or the 2023 NEC Handbook)Essential
The only reference allowed in the PSI exam room. Iowa adopted the 2023 NEC effective July 1, 2025. Ugly's Electrical References is explicitly not allowed.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 edition, or the 2023 NEC Handbook (allowed in the exam room; Ugly's is not)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 10 | |
| Wiring and Protection | 25 | |
| Wiring Methods and Materials | 25 | |
| Equipment for General Use | 20 | |
| Special Occupancies | 5 | |
| Special Equipment | 5 | |
| Special Conditions | 5 | |
| Communication Systems | 5 |
The outline totals 100; the other items on the 60-question exam are unscored or unassigned.
Exam day details
- Administered by PSI Services for the Iowa Electrical Examining Board.
- Fee: $87 to PSI per exam; not refundable or transferable and valid for 6 months. The Board's license application and license fees are separate.
- 60 scored questions plus 6 unscored items in 180 minutes (plus 15 minutes for the unscored items); 70% correct to pass.
- Open book: bring your own NFPA 70 (2023) or the 2023 NEC Handbook. Ugly's Electrical References is NOT allowed. You may highlight, underline and index with permanent tabs, but not write in the book; sticky notes are removed.
- PSI also gives you an on-screen calculator; you may bring a silent, battery-operated, non-programmable calculator with no paper tape.
- Send the Board your license application and a Testing Sponsorship Request. When it approves you, you get an authorization letter valid for 2 exam attempts or 6 months; then you pay and schedule with PSI. After two failures, contact the Board for a new letter.
- PSI tests at four Iowa centers and any other PSI site. The license fee is due after you pass.
Frequently asked questions
What's on the Iowa master residential electrician exam?
60 scored questions: wiring and protection 25, wiring methods and materials 25, equipment for general use 20, general electrical knowledge 10, special occupancies 5, special equipment 5, special conditions 5 and communication systems 5.
Is the exam open book?
Yes, with NFPA 70 (2023) or the 2023 NEC Handbook. Ugly's is not allowed.
How much does the exam cost?
$87 to PSI, valid for six months and not refundable. The Board's license fee is due after you pass.
Free questions with answers
Show all 10 free questions and answers
A 120-volt, two-wire copper branch circuit carries 16 amperes to a load 100 feet from the panel. Using VD = 2 x K x I x L / CM with K = 12.9 and the conductor areas in Chapter 9, Table 8, what is the smallest conductor that keeps the voltage drop at or below the 3 percent suggested in the 210.19 informational note?
Answer: 8 AWG (16,510 cmil)
Allowed drop = 3% x 120 V = 3.6 V. CM = 2 x 12.9 x 16 x 100 / 3.6 = 41,280 / 3.6 = 11,467 cmil. 10 AWG (10,380 cmil) is just short and gives about 3.98 V (3.3%); 12 AWG gives 6.3 V (5.3%). The smallest size with at least 11,467 cmil is 8 AWG (16,510 cmil). 6 AWG works but is larger than needed. The 210.19 note is advisory, not a mandatory limit.
Reference: NFPA 70, National Electrical Code, 2023, 210.19, Informational Note; Chapter 9, Table 8
A 20-ampere branch circuit supplies the receptacle outlet required by 210.52(D) in a dwelling bathroom. If the same circuit is also to supply the lighting and exhaust fan in that bathroom, how many bathrooms may the circuit serve under the 210.11(C)(3) exception?
Answer: One bathroom only
210.11(C)(3) requires a 20-ampere bathroom circuit with no other outlets, but its exception allows other outlets for equipment in the same bathroom only where the circuit supplies a single bathroom. Serving several bathrooms means the circuit may carry only the receptacle outlets.
Reference: NFPA 70, National Electrical Code, 2023, 210.11(C)(3), Exception
Type UF cable for a 240-volt circuit is direct buried under a 4-in.-thick concrete patio slab that carries no vehicles and extends more than 6 in. beyond the cable on all sides. What minimum cover does Table 300.5(A) require?
Answer: 18 in.
For direct-burial cables (Column 1), the row for a minimum 4-in. exterior slab with no vehicular traffic, extending at least 6 in. beyond the installation, gives 18 in. The 4-in. value is for rigid metal or IMC and nonmetallic raceways (Columns 2 and 3), 6 in. is the 120-volt, 20-ampere GFCI residential column, which does not apply to a 240-volt circuit, and 24 in. is the general Column 1 value for areas not covered by another row.
Reference: NFPA 70, National Electrical Code, 2023, 300.5(A), Table 300.5(A)
What minimum cover is required for rigid metal conduit buried in a lawn at a one-family dwelling under Table 300.5(A)?
Answer: 6 in.
Table 300.5(A), Column 2 permits 6 in. of cover for rigid metal conduit or intermediate metal conduit in the general location row. Nonmetallic raceways such as PVC need 18 in. in the same row, and direct-burial cable needs 24 in.
Reference: NFPA 70, National Electrical Code, 2023, 300.5(A), Table 300.5(A), Column 2
Under 406.12, which of the following receptacles in a new one-family dwelling must be listed tamper-resistant?
Answer: A 15-ampere, 125-volt receptacle in a bedroom
406.12 requires 15- and 20-ampere, 125- and 250-volt receptacles in the dwelling areas specified in 210.52 and similar locations to be listed tamper-resistant. Exceptions include receptacles more than 5 1/2 ft above the floor, receptacles that are part of a luminaire or appliance, and a single or duplex receptacle for appliances in dedicated spaces that are not easily moved.
Reference: NFPA 70, National Electrical Code, 2023, 406.12
Lamps for general illumination on a construction site's temporary lighting string must be protected from accidental contact or breakage. Which means satisfies 590.4(F)?
Answer: A suitable luminaire or lampholder with a guard
590.4(F) requires lamps for general illumination to be protected from accidental contact or breakage by a suitable luminaire or lampholder with a guard. Metal-guarded sockets may not be used unless the metal guard is connected to the circuit's equipment grounding conductor.
Reference: NFPA 70, National Electrical Code, 2023, 590.4(F)
A homeowner's manually switched optional standby generator will power only the loads the homeowner chooses to connect at one time. What capacity must the system have under 702.4(A)(1)?
Answer: Adequate capacity for all equipment intended to be operated at one time
For manual or nonautomatic load connection, 702.4(A)(1) requires an optional standby system to have adequate capacity and rating for all equipment intended to be operated at one time, and the user may select the load connected. Automatic connection requires the source to supply the full load that is automatically connected, or the maximum load an energy management system permits.
Reference: NFPA 70, National Electrical Code, 2023, 702.4(A)(1)
Which mounting rule applies to a bonding device that provides a termination point for the intersystem bonding conductor, according to 800.100(B)(2)?
Answer: It must be mounted on nonremovable parts and not on a door or cover
800.100(B)(2) says a bonding device must not interfere with opening an equipment enclosure, must be mounted on nonremovable parts, and must not be mounted on a door or cover, even if the door or cover is nonremovable. This keeps the bond intact when the enclosure is opened.
Reference: NFPA 70, National Electrical Code, 2023, 800.100(B)(2)
Under 410.90, to which conductor must the screw shell of a lampholder be connected where the circuit has a grounded conductor?
Answer: The grounded conductor
410.90 requires the grounded conductor of a circuit that supplies a screw-shell lampholder to be connected to the screw shell. This keeps the exposed shell from being energized when someone changes a lamp. Switches interrupt the ungrounded conductor.
Reference: NFPA 70, National Electrical Code, 2023, 410.90
What minimum height above the maximum water level of a swimming pool may communications and TV coaxial cables be run overhead under 680.9(B)?
Answer: 10 ft
680.9(B) permits communications, radio and television coaxial cables within Chapter 8 at a height of not less than 3.0 m (10 ft) above the maximum water level of swimming and wading pools and diving structures, observation stands, towers or platforms. The 22.5 ft clearance applies to power service conductors.
Reference: NFPA 70, National Electrical Code, 2023, 680.9(B)
Sources
- PSI: Iowa Electrical Examining Board Candidate Information Bulletin (updated 9/19/2025) (opens in a new tab)
- Iowa Electrical Examining Board (opens in a new tab)
- Iowa DIAL: electrical permits and inspections (adopted NEC) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.