Requirements at a glance
| Agency | Iowa Electrical Examining Board (Dept. of Inspections, Appeals, & Licensing); exam by PSI |
|---|---|
| Experience | Class A: a registered apprenticeship plus four years as an apprentice electrician; other routes include 16,000 hours of licensed electrical work or 6,000 hours after an approved postsecondary program (481 IAC 401.2(6)) |
| Exam | 80 scored questions, 180 minutes, open book; 70% to pass |
| Books allowed | Open book: NFPA 70 (2023) or NEC Handbook 2023, permanent tabs only; Ugly's not allowed |
| Fees | $87 to PSI per exam (valid 6 months); license fee due after you pass |
Electricians applying to the Iowa Electrical Examining Board for a class A journeyman license: usually a registered apprenticeship plus four years as an apprentice electrician. Other routes include 16,000 hours of licensed electrical work, 4,000 commercial or industrial hours for residential licensees, or 6,000 hours after an approved postsecondary program (481 IAC 401.2(6)).
Official links
How to get licensed, step by step
Apply to the Board
Send the license application and a Testing Sponsorship Request to the Electrical Examining Board. No license application is needed if you already hold one.
Get your authorization letter
When the Board approves you it sends an authorization to test, valid for two exam attempts or six months.
Pay and schedule with PSI
Register with PSI, pay the $87 fee and pick one of the four Iowa centers or any other PSI site. Cancel at least 2 days ahead to keep your fee.
Pass and get licensed
You need 70%. After you pass, contact the Board for instructions and pay the license fee.
How to prepare
- Iowa adopted the 2023 NEC effective July 1, 2025 (DIAL says unamended). The PSI exam references the 2023 NEC; bring NFPA 70 or the NEC Handbook, 2023. Ugly's is not allowed.
- The PSI outline covers NEC topics only, with no Iowa-law section, so practice NEC lookups and trade math rather than state statutes.
- Allowed: highlighting, underlining and permanent tabs. Not allowed: writing in the book, sticky notes or loose papers. PSI also gives you an on-screen calculator.
- Wiring and protection is a quarter of the exam, then wiring methods and materials and equipment for general use. Drill ampacity, grounding, overcurrent protection and load calculations.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 edition (or the 2023 NEC Handbook)Essential
The only reference allowed in the PSI exam room. Iowa adopted the 2023 NEC effective July 1, 2025. Ugly's Electrical References is explicitly not allowed.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 edition, or the 2023 NEC Handbook (allowed in the exam room; Ugly's is not)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 13 | |
| Wiring and Protection | 25 | |
| Wiring Methods and Materials | 19 | |
| Equipment for General Use | 19 | |
| Special Occupancies | 13 | |
| Special Equipment | 6 | |
| Special Conditions | 6 |
The outline totals 101; the other items on the 80-question exam are unscored or unassigned.
Exam day details
- Administered by PSI Services for the Iowa Electrical Examining Board.
- Fee: $87 to PSI per exam; not refundable or transferable and valid for 6 months. The Board's license application and license fees are separate.
- 80 scored questions plus 8 unscored items in 180 minutes (plus 30 minutes for the unscored items); 70% correct to pass.
- The published percentages (13, 25, 19, 19, 13, 6, 6) add to 101 because of rounding.
- Open book: bring your own NFPA 70 (2023) or the 2023 NEC Handbook. Ugly's Electrical References is NOT allowed. You may highlight, underline and index with permanent tabs, but not write in the book; sticky notes are removed.
- PSI also gives you an on-screen calculator; you may bring a silent, battery-operated, non-programmable calculator with no paper tape.
- Send the Board your license application and a Testing Sponsorship Request. When it approves you, you get an authorization letter valid for 2 exam attempts or 6 months; then you pay and schedule with PSI. After two failures, contact the Board for a new letter.
- PSI tests at four Iowa centers and any other PSI site. The license fee is due after you pass.
Frequently asked questions
What's on the Iowa journeyman electrician exam?
80 scored questions: wiring and protection 25, wiring methods and materials 19, equipment for general use 19, general electrical knowledge 13, special occupancies 13, special equipment 6 and special conditions 6.
Is the Iowa electrician exam open book?
Yes. Bring NFPA 70 (2023) or the 2023 NEC Handbook, tabbed with permanent tabs. Ugly's Electrical References is not allowed.
Which NEC edition does Iowa use?
The 2023 NEC, adopted effective July 1, 2025.
What if I fail?
Your authorization letter covers two attempts or six months. After two failures, contact the Electrical Examining Board for a new letter.
Free questions with answers
Show all 10 free questions and answers
Two resistors, 30 ohms and 20 ohms, are connected in parallel. What is the equivalent resistance?
Answer: 12 ohms
For two parallel resistors R = (R1 x R2) / (R1 + R2) = (30 x 20) / 50 = 600 / 50 = 12 ohms. 50 ohms is the series total, 25 ohms is the simple average, and 15 ohms is half of the larger resistor, which has no basis in the formula.
Reference: NFPA 70, National Electrical Code, 2023, Basic electricity theory: series and parallel resistance
A balanced three-phase, 480-volt load is rated 60 kW at unity power factor. What is the line current? Use 1.732 for the square root of three.
Answer: 72.2 A
For three-phase I = P / (1.732 x E x PF) = 60,000 / (1.732 x 480 x 1.0) = 60,000 / 831.4 = 72.2 A. 125 A divides by 480 and leaves out the 1.732 factor. 41.7 A divides by 1.732 twice. 144.3 A uses 240 V instead of 480 V in the denominator.
Reference: NFPA 70, National Electrical Code, 2023, Basic electricity theory: three-phase power formula
In a dwelling unit, what does 210.11(C)(3) require for the bathroom receptacle outlets required by 210.52(D)?
Answer: At least one 120-volt, 20-ampere branch circuit with no other outlets, subject to its exception
Section 210.11(C)(3) calls for one or more 120-volt, 20-ampere branch circuits supplying the bathroom receptacle outlets and any countertop receptacle outlets, with no other outlets on those circuits. The exception lets a 20-ampere circuit that serves a single bathroom also supply other equipment in that same bathroom.
Reference: NFPA 70, National Electrical Code, 2023, 210.11(C)(3)
What is the maximum spacing for securing and supporting Type NM cable under 334.30, with a securing point also required within 12 in. of each box?
Answer: 4 1/2 ft
Section 334.30 requires nonmetallic-sheathed cable to be supported and secured at intervals not exceeding 1.4 m (4 1/2 ft) and within 300 mm (12 in.) of every cable entry into a box, cabinet or fitting. 3 ft and 10 ft are EMT and conduit values, and 6 ft is the MC cable interval.
Reference: NFPA 70, National Electrical Code, 2023, 334.30
A pull box has an angle pull. A 3-in. raceway and a 2-in. raceway enter the same wall in one row, and the conductors are 2 AWG. What is the minimum distance from the entries to the opposite wall under 314.28(A)(2)?
Answer: 20 in.
For an angle pull, the distance to the opposite wall is six times the trade size of the largest raceway in the row, plus the sum of the other raceway sizes in that row on the same wall: (6 x 3) + 2 = 18 + 2 = 20 in. 18 in. leaves out the added raceway, 24 in. is eight times the 3-in. raceway (the straight-pull rule), and 23 in. adds both raceways to six times the 3-in. size (18 + 3 + 2).
Reference: NFPA 70, National Electrical Code, 2023, 314.28(A)(2)
A 7.5-hp, 460-volt, three-phase induction motor has a nameplate current of 10.4 A. Using 430.6(A)(1), 430.22 and Table 430.250, what is the minimum ampacity of the branch-circuit conductors for this continuous-duty motor?
Answer: 13.75 A
For conductor sizing, 430.6(A)(1) requires the full-load current from Table 430.250, not the nameplate: 11 A for a 7.5-hp, 460-V motor. Section 430.22 requires 125 percent: 11 x 1.25 = 13.75 A. 13.0 A uses the nameplate (10.4 x 1.25), 11.0 A omits the 125 percent factor, and 27.5 A applies 250 percent, which is the breaker rule for short-circuit protection, not the conductor rule.
Reference: NFPA 70, National Electrical Code, 2023, 430.6(A)(1) and 430.22
A continuous-duty motor has a nameplate full-load current of 18.6 A and a marked service factor of 1.15. Under 430.32(A)(1), what is the maximum trip or rating of a separate overload device?
Answer: 23.25 A
Section 430.32(A)(1) permits a separate overload device of not more than 125 percent of nameplate current for motors with a marked service factor of 1.15 or greater or a marked temperature rise of 40 degrees C or less. 18.6 x 1.25 = 23.25 A. 21.4 A uses 115 percent, which applies to all other motors, 18.6 A is the nameplate alone, and 27.9 A uses 150 percent.
Reference: NFPA 70, National Electrical Code, 2023, 430.32(A)(1)
How does 500.5(B)(1) and its informational note classify the interior of a spray booth where volatile flammable solvents are used?
Answer: Class I, Division 1
The informational note to 500.5(B)(1) lists the interiors of spray booths and areas in the vicinity of spraying and painting where volatile flammable solvents are used among locations that usually are Class I, Division 1, because ignitible concentrations of vapors can exist under normal operating conditions. Class II is for combustible dust and Class III is for ignitible fibers and flyings, so neither fits solvent vapors.
Reference: NFPA 70, National Electrical Code, 2023, 500.5(B)(1)
Under 680.22(A)(1), a permanently installed pool must have at least one general-purpose receptacle located within what range of distances from the inside wall of the pool?
Answer: At least 6 ft and not more than 20 ft
Section 680.22(A)(1) requires no fewer than one 125-volt, 15- or 20-ampere receptacle on a general-purpose branch circuit located not less than 1.83 m (6 ft) and not more than 6.0 m (20 ft) from the inside wall of the pool, and not more than 6 ft 6 in. above the floor, platform or grade serving the pool.
Reference: NFPA 70, National Electrical Code, 2023, 680.22(A)(1)
An office building has a generator-supplied emergency system for egress lighting. Under 700.12, once the normal supply fails, the emergency lighting must come on within the time the application requires, but never later than what limit?
Answer: 10 seconds
Section 700.12 requires emergency lighting and power to be available within the time required for the application but not to exceed 10 seconds. The 60-second limit is for legally required standby systems under 701.12, and optional standby has no time limit in Article 702.
Reference: NFPA 70, National Electrical Code, 2023, 700.12
Sources
- PSI: Iowa Electrical Examining Board Candidate Information Bulletin (updated 9/19/2025) (opens in a new tab)
- Iowa Electrical Examining Board (opens in a new tab)
- Iowa DIAL: electrical permits and inspections (adopted NEC) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.