Requirements at a glance
| Agency | Iowa Electrical Examining Board (Dept. of Inspections, Appeals, & Licensing); exam by PSI |
|---|---|
| Experience | Special electrician Endorsement 1: pass this exam or document two years (4,000 hours) of irrigation system wiring (481 IAC 401.2(9)) |
| Exam | 50 scored questions, 120 minutes, open book; 70% to pass |
| Books allowed | Open book: NFPA 70 (2023) or NEC Handbook 2023, permanent tabs only; Ugly's not allowed |
| Fees | $87 to PSI per exam (valid 6 months); license fee due after you pass |
Installers seeking the Irrigation System Wiring endorsement (Endorsement 1) on an Iowa special electrician license. You qualify by passing this exam or by documenting two years (4,000 hours) of irrigation system wiring (481 IAC 401.2(9)).
Official links
How to get licensed, step by step
Apply to the Board
Send the license application and a Testing Sponsorship Request to the Electrical Examining Board. No license application is needed if you already hold one.
Get your authorization letter
When the Board approves you it sends an authorization to test, valid for two exam attempts or six months.
Pay and schedule with PSI
Register with PSI, pay the $87 fee and pick one of the four Iowa centers or any other PSI site. Cancel at least 2 days ahead to keep your fee.
Pass and get licensed
You need 70%. After you pass, contact the Board for instructions and pay the license fee.
How to prepare
- Iowa adopted the 2023 NEC effective July 1, 2025 (DIAL says unamended). The PSI exam references the 2023 NEC; bring NFPA 70 or the NEC Handbook, 2023. Ugly's is not allowed.
- The PSI outline covers NEC topics only, with no Iowa-law section, so practice NEC lookups and trade math rather than state statutes.
- Allowed: highlighting, underlining and permanent tabs. Not allowed: writing in the book, sticky notes or loose papers. PSI also gives you an on-screen calculator.
- Low voltage and special equipment are 28% of the exam. Review grounding and bonding, low-voltage (Class 2) circuits and wiring protection for outdoor equipment. Simplified Irrigation Design is not allowed in the room.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 edition (or the 2023 NEC Handbook)Essential
The only reference allowed in the PSI exam room. Iowa adopted the 2023 NEC effective July 1, 2025. Ugly's Electrical References is explicitly not allowed.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 edition, or the 2023 NEC Handbook (allowed in the exam room; Ugly's is not)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 12 | |
| Wiring and Protection | 20 | |
| Wiring Methods and Materials | 20 | |
| Equipment for General Use | 20 | |
| Special Equipment | 14 | |
| Low Voltage | 14 |
The outline totals 100; the other items on the 50-question exam are unscored or unassigned.
Exam day details
- Administered by PSI Services for the Iowa Electrical Examining Board.
- Fee: $87 to PSI per exam; not refundable or transferable and valid for 6 months. The Board's license application and license fees are separate.
- 50 scored questions plus 5 unscored items in 120 minutes (plus 15 minutes for the unscored items); 70% correct to pass.
- The PSI bulletin lists Simplified Irrigation Design (Pete Melby, 2nd edition) under reference material NOT allowed in the examination center.
- Open book: bring your own NFPA 70 (2023) or the 2023 NEC Handbook. Ugly's Electrical References is NOT allowed. You may highlight, underline and index with permanent tabs, but not write in the book; sticky notes are removed.
- PSI also gives you an on-screen calculator; you may bring a silent, battery-operated, non-programmable calculator with no paper tape.
- Send the Board your license application and a Testing Sponsorship Request. When it approves you, you get an authorization letter valid for 2 exam attempts or 6 months; then you pay and schedule with PSI. After two failures, contact the Board for a new letter.
- PSI tests at four Iowa centers and any other PSI site. The license fee is due after you pass.
Frequently asked questions
What's on the Iowa irrigation system wiring exam?
50 scored questions: wiring and protection 20, wiring methods and materials 20, equipment for general use 20, special equipment 14, low voltage 14 and general knowledge 12.
Is the exam open book?
Yes, with NFPA 70 (2023) or the 2023 NEC Handbook. Ugly's is not allowed.
How much does the exam cost?
$87 to PSI, valid for six months and not refundable.
Free questions with answers
Show all 10 free questions and answers
Under the Article 100 definitions, which description fits a center pivot irrigation machine?
Answer: A multimotored irrigation machine that revolves around a central pivot and uses alignment switches or similar devices to control its individual motors
Article 100 defines Center Pivot Irrigation Machine as a multimotored machine that revolves around a central pivot and uses alignment switches or similar devices to control individual motors. That is why Part II of Article 675 gives it its own equivalent current rules. The other choices describe machines that are not defined that way.
Reference: NFPA 70, National Electrical Code, 2023, Article 100, Irrigation Machine, Center Pivot
A 20-ampere branch circuit with a standard (not 100 percent rated) breaker supplies a landscape lighting transformer that will operate for more than 3 hours at a time. What is the greatest continuous load that circuit may carry?
Answer: 16 A
The overcurrent device must be rated at least the noncontinuous load plus 125 percent of the continuous load (210.20(A)), so the continuous load may not exceed 20 / 1.25 = 16 A. Using the full 20 A ignores the 125 percent rule; 18 A and 12 A are not Code values.
Reference: NFPA 70, National Electrical Code, 2023, 210.20(A)
A feeder to an irrigation pump house carries 22 A of continuous load and 6 A of noncontinuous load. It uses copper THWN conductors, and all terminations are rated 60 degrees C. Using Table 310.16, which is the smallest conductor that can be used (no adjustment or correction applies)?
Answer: 8 AWG
Minimum feeder ampacity is the noncontinuous load plus 125 percent of the continuous load (215.2(A)(1)): 6 + (22 x 1.25) = 6 + 27.5 = 33.5 A. In the 60 degree C copper column of Table 310.16, 10 AWG is only 30 A, which is too small, while 8 AWG is 40 A. 10 AWG would pass only if the 75 degree C value of 35 A were used, which the 60 degree C terminations do not allow.
Reference: NFPA 70, National Electrical Code, 2023, 215.2(A)(1) and Table 310.16
A 240-volt irrigation pump circuit is wired with Type UF cable buried directly in the earth in a location with no special conditions, such as a driveway or slab. What minimum cover is required?
Answer: 24 in.
Column 1 of Table 300.5(A) (direct-buried cables and conductors) calls for 24 in. of cover in all locations not otherwise specified. 6 in. is for rigid metal conduit, 18 in. is for nonmetallic raceways listed for direct burial, and 12 in. is only for residential 120-volt, 20-ampere GFCI-protected circuits.
Reference: NFPA 70, National Electrical Code, 2023, Table 300.5(A), Column 1
A 120-volt, 20-ampere GFCI-protected residential branch circuit to a yard pump receptacle is run in Type UF cable buried directly in the earth. What is the minimum cover?
Answer: 12 in.
Column 4 of Table 300.5(A) allows 12 in. of cover for residential branch circuits rated 120 volts or less with GFCI protection and maximum overcurrent protection of 20 A. Without those conditions the 24-in. Column 1 value would apply.
Reference: NFPA 70, National Electrical Code, 2023, Table 300.5(A), Column 4
A 5-hp, 230-volt, single-phase continuous-duty pump motor is supplied by copper conductors with 75 degree C terminations at both ends. Using Table 430.248 for the full-load current, what is the smallest THWN copper conductor?
Answer: 10 AWG
Table 430.248 gives 28 A for a 5-hp, 230-V single-phase motor. Branch-circuit conductors to a single continuous-duty motor must have an ampacity of at least 125 percent of that current (430.22): 28 x 1.25 = 35 A. In the 75 degree C copper column of Table 310.16, 10 AWG is 35 A. 12 AWG (25 A) is too small, and 8 AWG (50 A) is larger than necessary.
Reference: NFPA 70, National Electrical Code, 2023, 430.22 and Table 430.248
Three 230-volt, three-phase motors on one feeder are 5 hp, 3 hp and 2 hp. Using Table 430.250 (15.2 A, 9.6 A and 6.8 A), what is the minimum ampacity of the feeder conductors?
Answer: 35.4 A
Feeder conductors to several motors must carry 125 percent of the largest motor plus the sum of the others (430.24): (15.2 x 1.25) + 9.6 + 6.8 = 19.0 + 16.4 = 35.4 A. 31.6 A is the plain sum of the three motors, 38.0 A is 250 percent of the largest motor, and 39.5 A applies 125 percent to every motor.
Reference: NFPA 70, National Electrical Code, 2023, 430.24 and Table 430.250
A center pivot irrigation machine has a 5-hp tower-drive motor with a nameplate full-load current of 7.6 A and eight other motors with nameplate full-load currents of 2.1 A each. What is the equivalent continuous-current rating used to select the branch-circuit conductors?
Answer: 19.6 A
For center pivot machines, the equivalent continuous-current rating is 125 percent of the largest motor's nameplate current plus 60 percent of the sum of the remaining motors (675.22(A)). Largest: 7.6 x 1.25 = 9.5 A. Remaining: 8 x 2.1 = 16.8 A, and 16.8 x 0.60 = 10.08 A. Total = 9.5 + 10.08 = 19.6 A. 24.4 A uses 100 percent of the remaining motors with no 125 percent, 17.7 A omits the 125 percent on the largest motor, and 30.5 A takes 125 percent of everything.
Reference: NFPA 70, National Electrical Code, 2023, 675.22(A)
Which statement describes the main disconnecting means for an irrigation machine?
Answer: It provides overcurrent protection, is at the point of power connection or in sight, and is readily accessible and lockable open
The main disconnecting means must provide overcurrent protection, be at the point of connection of power to the machine or in sight from it, and be readily accessible and lockable open under 110.25 (675.8(B)). It must also have horsepower and current ratings not less than the main controller requires.
Reference: NFPA 70, National Electrical Code, 2023, 675.8(B)
Under the notes to Chapter 9 Tables 11(A) and 11(B), what is the maximum source voltage (Vmax) for a sinusoidal ac Class 2 power source where wet contact is likely, if Class 3 wiring methods are not used?
Answer: 15 volts
Where wet contact (immersion not included) is likely, Class 3 wiring methods must be used or the maximum voltage must not exceed 15 volts for sinusoidal ac and 21.2 volts peak for nonsinusoidal ac (Note 2 to Tables 11(A) and 11(B)). The 30-volt value is the general indoor limit for sinusoidal ac, which does not apply to wet contact.
Reference: NFPA 70, National Electrical Code, 2023, Chapter 9, Notes to Tables 11(A) and 11(B), Note 2
Sources
- PSI: Iowa Electrical Examining Board Candidate Information Bulletin (updated 9/19/2025) (opens in a new tab)
- Iowa Electrical Examining Board (opens in a new tab)
- Iowa DIAL: electrical permits and inspections (adopted NEC) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.