Iowa Master HVAC/Refrigeration Exam: Practice Test & Licensing Guide

The Kirkwood exam for an Iowa master HVAC/refrigeration license with gas: 100 open-book questions in 4 hours on HVAC principles, the 2024 IMC and 2024 NFPA 54. 75% to pass.

Questions
100
Time limit
4 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10HVAC Terms, Principles, Administration

A contractor replaces a failed blower motor and control board in an existing furnace, using the same arrangement and parts as the original system. The work is not hazardous. Under IMC Section 102.4, how are such minor repairs treated?

Requirements at a glance

AgencyIowa Plumbing and Mechanical Systems Board (PMSB); exam by Kirkwood Community College
ExperienceA prior journeyperson license plus 2 years in the discipline, or a master license from another state
Exam100 questions, 4 hours, open book; 75% to pass
Books allowedModern Refrigeration and Air Conditioning (21st ed., Goodheart-Willcox), 2024 IMC and 2024 NFPA 54
Fees$119 to Kirkwood plus a $35 PMSB exam-candidate application per exam

Candidates with a prior journeyperson license plus 2 years in the discipline (or a master license elsewhere) applying to the Plumbing and Mechanical Systems Board.

How to get licensed, step by step

  1. Apply to the PMSB

    Submit the exam-candidate application and fee to the Plumbing and Mechanical Systems Board for approval.

    Iowa DIAL: plumbing and mechanical examination (opens in a new tab)

  2. Register with Kirkwood

    Register and pay Kirkwood for your exam, then test at one of about 16 Iowa community-college centers. Fees are non-refundable and non-transferable.

    Kirkwood: Iowa state discipline exams (opens in a new tab)

  3. Take the exam

    Bring your approved references and a battery-operated, non-programmable calculator. You need 75% to pass.

    Kirkwood: Iowa state discipline exams (opens in a new tab)

  4. Apply for your license

    After you pass, send the Board a post-examination licensure application. If you fail, register and pay for a new exam (Kirkwood, 319-398-1022).

    Iowa DIAL: plumbing and mechanical examination (opens in a new tab)

How to prepare

  • Kirkwood's outlines say questions are based on the listed edition, but you may bring any edition. Iowa adopted the 2024 UPC and 2024 IMC with amendments effective March 26, 2025.
  • Code books may be bound or loose-leaf. Photocopies, handwritten notes and sticky notes are not allowed; highlighting and permanent tabs are.
  • The exam is open book, so tab each chapter and practice finding answers fast.
  • Refrigeration (20%) and venting, duct and combustion air (18%) lead the outline. The master exam adds an HVAC electrical section (13%); review control wiring and motor circuits.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from Modern Refrigeration and the 2024 IMC and NFPA 54. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • Modern Refrigeration and Air Conditioning, 21st edition (Goodheart-Willcox)
  • 2024 International Mechanical Code (IMC), ICC, with Iowa amendments (481 IAC 426)
  • 2024 NFPA 54 National Fuel Gas Code

What's on the exam

Official content outline from Kirkwood Community College (number of questions per topic):

TopicQuestions
HVAC Terms, Principles, Administration16
HVAC Installation14
Venting, Duct, Combustion Air18
Gas Piping8
HVAC Electrical13
Boilers, Exhaust, and Fire Protection11
Refrigeration Term System, Operation20

Exam day details

  • Administered by Kirkwood Community College for the Iowa Plumbing and Mechanical Systems Board (PMSB).
  • Fee: $119 to Kirkwood per exam, plus a $35 PMSB exam-candidate application per exam. Exam fees are non-refundable and non-transferable.
  • 100 questions in 4 hours (Master HVAC/Refrigeration with Gas); 75% to pass.
  • Iowa adopted the 2024 IMC with amendments (481 IAC 426), effective March 26, 2025; fuel gas references are NFPA 54 and NFPA 58 (current edition).
  • Open book: bring the references listed. Code books may be bound or loose-leaf; photocopies are not allowed. You may highlight and add permanent tabs before the exam, but handwritten notes in the books are not allowed and sticky notes are not accepted.
  • Exam questions are based on the listed edition, but the books you bring may be any edition.
  • You may bring an architect's scale or rule and a battery-operated, non-programmable calculator with no printing capability.
  • Kirkwood tests at about 16 Iowa community-college centers. Pass with 75%; then send the PMSB a post-examination licensure application. If you fail you must register and pay for a new exam.

Frequently asked questions

What's on the Iowa master HVAC/R exam?

100 questions: refrigeration term, system and operation 20%, venting, duct and combustion air 18%, HVAC terms, principles and administration 16%, HVAC installation 14%, HVAC electrical 13%, boilers, exhaust and fire protection 11% and gas piping 8%.

Which books are allowed?

Modern Refrigeration and Air Conditioning (21st edition, Goodheart-Willcox), the 2024 IMC and the 2024 NFPA 54.

Does this replace the EPA 608 exam?

No. EPA Section 608 certification is a separate federal requirement for handling refrigerants.

Free questions with answers

Show all 10 free questions and answers
  1. A contractor replaces a failed blower motor and control board in an existing furnace, using the same arrangement and parts as the original system. The work is not hazardous. Under IMC Section 102.4, how are such minor repairs treated?

    Answer: They must meet the provisions for new construction unless done in the same manner and arrangement as the existing system, not hazardous, and approved

    Section 102.4 says additions, alterations, renovations or repairs conform to what is required of a new system without forcing the whole existing system to comply, and minor work meets new-construction provisions unless it is done in the same manner and arrangement as the existing system, is not hazardous and is approved. An owner statement is not part of the test, and the work may not make the system unsafe or overloaded.

    Reference: 2024 International Mechanical Code, Section 102.4

  2. Under 40 CFR 82.161(a)(4), what must a certified technician do with the copy of his or her certificate?

    Answer: Keep a copy at the place of business, and keep it until three years after no longer operating as a technician

    Section 82.161(a)(4) requires technicians certified under the section to keep a copy of their certificate at their place of business and to keep it until three years after they stop operating as a technician. The rule does not require filing with a state board.

    Reference: 40 CFR 82.161(a)(4), 40 CFR 82.161(a)(4)

  3. A water heater is set in a pit that is 20 inches below adjoining grade. Under IMC Section 303.7, which set of requirements applies to the pit?

    Answer: Appliance at least 3 inches above the pit floor, pit sides held back at least 12 inches, and walls lined with concrete or masonry extending at least 4 inches above grade

    Section 303.7 requires an appliance in a pit to stay out of direct contact with the soil and sit at least 3 inches above the pit floor, with the sides held back at least 12 inches. Where the depth exceeds 12 inches below adjoining grade, the walls must be lined with concrete or masonry extending at least 4 inches above adjoining grade, the control side excavation must extend at least 30 inches, and the appliance must be protected from flooding. At 20 inches this pit is past the 12-inch trigger.

    Reference: 2024 International Mechanical Code, Section 303.7

  4. A package unit is placed at grade level on a slab. Under IMC Section 304.10, how far above adjoining grade must the slab or support extend, unless the unit is suspended?

    Answer: At least 3 inches above adjoining grade, or the unit suspended at least 6 inches above grade

    Section 304.10 requires equipment installed at grade to rest on a level concrete slab or other approved material at least 3 inches above adjoining grade, or to be suspended at least 6 inches above adjoining grade, in accordance with the manufacturer's installation instructions.

    Reference: 2024 International Mechanical Code, Section 304.10

  5. A utility room holds an 80,000 Btu/h furnace and a 40,000 Btu/h water heater, and all combustion air will come from inside the building. Using the standard method, what is the minimum room volume, counting only this room?

    Answer: 6,000 cubic feet

    The standard method requires 50 cubic feet per 1,000 Btu/h of the total input of all appliances in the space. Total input = 80,000 + 40,000 = 120,000 Btu/h, so volume = 120 x 50 = 6,000 cubic feet. Using 20, 40 or 60 cubic feet per 1,000 Btu/h gives the distractors. Rooms joined by unclosed openings sized to the code may be counted toward the volume.

    Reference: NFPA 54 (2024), 9.3.2.1

  6. The two outdoor openings for a 140,000 Btu/h appliance group are connected to the outdoors through horizontal ducts. What minimum free area does each opening need under the two-opening method?

    Answer: 70 square inches

    Where the openings reach the outdoors through horizontal ducts, each needs 1 square inch per 2,000 Btu/h of total input: 140,000 / 2,000 = 70 square inches. Direct openings or vertical ducts use 1 square inch per 4,000 Btu/h (35 square inches). The 46.7 figure is a louver-area result, not a duct result.

    Reference: NFPA 54 (2024), 9.3.3.1(2)

  7. A gas piping system on natural gas (1,000 Btu per cubic foot) uses Schedule 40 steel pipe sized by the longest length method at a 0.5 in. w.c. drop. The longest run is 40 feet, and the section serving a 100,000 Btu/h furnace and a 40,000 Btu/h water heater must be sized. Using the 0.5 in. w.c. table, what pipe size is needed?

    Answer: 3/4 inch

    Total load = 140,000 Btu/h / 1,000 = 140 cubic feet per hour. In the 40-foot row the table gives 81 cfh for 1/2 inch, 170 for 3/4 inch and 320 for 1 inch. 3/4 inch is the smallest size that carries at least 140 cfh. The longest length method uses the full 40 feet for every section.

    Reference: NFPA 54 (2024), 6.1 (Pipe Sizing Methods, longest length method) and Table 6.2.1(b)

  8. Three resistive heating elements of 10, 20 and 30 ohms are connected in parallel across 120 volts. What is the total current?

    Answer: About 22 amperes

    Parallel resistance: 1/R = 1/10 + 1/20 + 1/30 = 0.1833, so R = 5.45 ohms. Current = 120 / 5.45 = 22 A. Adding the resistances (60 ohms) as if in series gives 2 A. Branch currents are 12 + 6 + 4 = 22 A.

    Reference: Modern Refrigeration and Air Conditioning, 21st Edition, Concept: Ohm's law and parallel circuits

  9. A boiler room is laid out with equipment on both sides of the boiler. Under IMC Section 1004.3, what is the minimum unobstructed width of the passageways around all sides of boilers, unless otherwise approved?

    Answer: 18 inches

    Section 1004.3 requires clearances that allow inspection, servicing, repair, replacement and visibility of all gauges, with passageways around all sides of boilers having an unobstructed width of at least 18 inches unless otherwise approved. The 30-inch dimension is the level service space for appliances in Section 306.

    Reference: 2024 International Mechanical Code, Section 1004.3

  10. A technician recovers R-410A from an owner's rooftop unit and wants to reuse it in a different owner's system after filtering. What does IMC Section 1102.2.2 require?

    Answer: Reclaim it and test it to AHRI 700 purity before using it in a different owner's equipment

    Section 1102.2.2.2 says recovered refrigerant may only be reused in the system it came from and other systems of the same owner, after filtering and drying. Section 1102.2.2.3 says used refrigerant may not be reused in a different owner's equipment unless tested and found to meet AHRI 700 purity, so it must be reclaimed.

    Reference: 2024 International Mechanical Code, Sections 1102.2.2.2 and 1102.2.2.3