Requirements at a glance
| Agency | Iowa Plumbing and Mechanical Systems Board (PMSB); exam by Kirkwood Community College |
|---|---|
| Experience | 36 months of DOL apprenticeship (you may test up to 6 months before the 48 months of credit), or 4 years of experience before January 1, 2010 |
| Exam | 75 questions, 2 hours, open book; 75% to pass |
| Books allowed | Modern Refrigeration and Air Conditioning (21st ed., Goodheart-Willcox), 2024 IMC and 2024 NFPA 54 |
| Fees | $119 to Kirkwood plus a $35 PMSB exam-candidate application per exam |
HVAC/refrigeration workers applying to the Plumbing and Mechanical Systems Board for a journeyperson license: 36 months of DOL apprenticeship (you may test up to 6 months before the 48 months of credit), or 4 years of experience before January 1, 2010.
Official links
How to get licensed, step by step
Apply to the PMSB
Submit the exam-candidate application and fee to the Plumbing and Mechanical Systems Board for approval.
Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
Register with Kirkwood
Register and pay Kirkwood for your exam, then test at one of about 16 Iowa community-college centers. Fees are non-refundable and non-transferable.
Take the exam
Bring your approved references and a battery-operated, non-programmable calculator. You need 75% to pass.
Apply for your license
After you pass, send the Board a post-examination licensure application. If you fail, register and pay for a new exam (Kirkwood, 319-398-1022).
Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
How to prepare
- Kirkwood's outlines say questions are based on the listed edition, but you may bring any edition. Iowa adopted the 2024 UPC and 2024 IMC with amendments effective March 26, 2025.
- Code books may be bound or loose-leaf. Photocopies, handwritten notes and sticky notes are not allowed; highlighting and permanent tabs are.
- The exam is open book, so tab each chapter and practice finding answers fast.
- Refrigeration (24%) and venting, combustion and gas piping (23%) lead the outline. Know the refrigeration cycle, superheat and subcooling, and tab the IMC and NFPA 54 for vent and gas sizing.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from Modern Refrigeration and the 2024 IMC and NFPA 54. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Modern Refrigeration and Air Conditioning, 21st edition (Goodheart-Willcox)Essential
Listed in Kirkwood's HVAC/refrigeration references; refrigeration and HVAC principles questions draw on it.
2024 International Mechanical Code (IMC), ICCEssential
Iowa's mechanical code (481 IAC 426) with Iowa amendments, effective March 26, 2025.
2024 NFPA 54 National Fuel Gas CodeEssential
Iowa's mechanical amendments point to NFPA 54 and NFPA 58 instead of the IFGC for fuel gas.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- Modern Refrigeration and Air Conditioning, 21st edition (Goodheart-Willcox)
- 2024 International Mechanical Code (IMC), ICC, with Iowa amendments (481 IAC 426)
- 2024 NFPA 54 National Fuel Gas Code
What's on the exam
Official content outline from Kirkwood Community College (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| HVAC Principles, Terms, Administration, and Safety | 21 | |
| HVAC Installation Requirements | 15 | |
| Venting, Combustion, Gas Piping | 23 | |
| Boilers, Ducts, Electricals | 17 | |
| Refrigeration, Terms, System Operations | 24 |
The outline totals 100; the other items on the 75-question exam are unscored or unassigned.
Exam day details
- Administered by Kirkwood Community College for the Iowa Plumbing and Mechanical Systems Board (PMSB).
- Fee: $119 to Kirkwood per exam, plus a $35 PMSB exam-candidate application per exam. Exam fees are non-refundable and non-transferable.
- 75 questions in 2 hours (Journeyperson HVAC/Refrigeration with Gas); 75% to pass.
- Iowa adopted the 2024 IMC with amendments (481 IAC 426), effective March 26, 2025; fuel gas references are NFPA 54 and NFPA 58 (current edition).
- Open book: bring the references listed. Code books may be bound or loose-leaf; photocopies are not allowed. You may highlight and add permanent tabs before the exam, but handwritten notes in the books are not allowed and sticky notes are not accepted.
- Exam questions are based on the listed edition, but the books you bring may be any edition.
- You may bring an architect's scale or rule and a battery-operated, non-programmable calculator with no printing capability.
- Kirkwood tests at about 16 Iowa community-college centers. Pass with 75%; then send the PMSB a post-examination licensure application. If you fail you must register and pay for a new exam.
Frequently asked questions
What's on the Iowa journeyperson HVAC/R exam?
75 questions: refrigeration, terms and system operations 24%, venting, combustion and gas piping 23%, HVAC principles, terms, administration and safety 21%, boilers, ducts and electricals 17% and HVAC installation requirements 15%.
Which books are allowed?
Modern Refrigeration and Air Conditioning (21st edition, Goodheart-Willcox), the 2024 IMC and the 2024 NFPA 54.
Does this replace the EPA 608 exam?
No. EPA Section 608 certification is a separate federal requirement for handling refrigerants.
Free questions with answers
Show all 10 free questions and answers
A technician wants to top off an R-410A split system with a different refrigerant that the equipment maker approves in writing, and the blend would not change the refrigerant safety group. Under the IMC, how may refrigerants with different designations be mixed in a system?
Answer: Only when the equipment manufacturer allows it in written instructions and the mixture keeps the same safety group
Section 1102.2.1 permits mixing refrigerants of different designations only if the manufacturer allows the second refrigerant in its written instructions AND the resulting mixture does not change the safety group. Matching boiling points, an evacuation level or an A1 label do not satisfy either condition.
Reference: 2024 International Mechanical Code, Section 1102.2.1
While brazing a copper liquid line, a technician keeps oxygen-free nitrogen flowing through the tubing. After the pre-purge, what pressure range must the inert gas supply hold in the piping during brazing?
Answer: 1.0 psi minimum and 3.0 psi maximum
Section 1108.3.1 requires the inert gas to be maintained during brazing at 1.0 psi minimum and 3.0 psi maximum, with the gas connected directly to the tubing so ambient air is not drawn in. Higher pressures can blow molten filler out of the joint; lower ones let air in and cause oxide scale.
Reference: 2024 International Mechanical Code, Section 1108.3.1
An electric unit heater is hung in a private garage with its bottom 4 feet above the floor and no vehicle impact protection. What does IMC 304.7 require?
Answer: The appliance must be raised to at least 6 feet above the floor or be protected from vehicle impact
Section 304.7 requires appliances in private garages and carports to have at least 6 feet of clearance above the floor, unless the appliance is protected from motor vehicle impact and installed per Section 304.3 (ignition source elevation). A 4-foot mounting height meets neither option.
Reference: 2024 International Mechanical Code, Section 304.7
A steam boiler has a maximum allowable working pressure of 125 psig. Under IMC 1008.1, how many bottom blowoff valves are required and how are they arranged?
Answer: Two in series, with any quick-opening valve nearest the boiler
Section 1008.1 requires bottom blowoff valves on steam boilers and, where the MAWP exceeds 100 psig, two valves in series: either two slow-opening valves or one quick-opening and one slow-opening, with the quick-opening valve closest to the boiler. 125 psig is above the 100 psig threshold, so one valve is not enough.
Reference: 2024 International Mechanical Code, Section 1008.1
An acceptance test gauge is chosen for a boiler hydrostatic test at a maximum test pressure of 60 psi. Using IMC 1011.2, what gauge scale range is acceptable?
Answer: 90 psi through 240 psi (1.5 to 4 times)
Section 1011.2 requires the test gauge scale to be graduated over a range of not less than 1.5 times and not more than 4 times the maximum test pressure: 1.5 x 60 = 90 psi and 4 x 60 = 240 psi. A gauge topping out at the test pressure is below the minimum range.
Reference: 2024 International Mechanical Code, Section 1011.2
A device is proposed for the inside of a gas pipe that would reduce the cross-sectional area of the pipe. What does NFPA 54 say about placing such devices in gas piping?
Answer: They are prohibited unless the pipe sizing has made allowance for them
NFPA 54 7.9 prohibits devices inside the gas piping or fittings that reduce the cross-sectional area or obstruct free flow of gas, except where the piping system design has made allowance for them. Being listed or oversizing the pipe is not the test.
Reference: NFPA 54 (2024), 7.9
A leak is found at a threaded joint during a pressure test on new gas piping. According to NFPA 54, how is it handled?
Answer: The affected portion is repaired or replaced and retested
NFPA 54 8.1.5.3 requires that where leakage or other defects are located, the affected portion of the piping system be repaired or replaced and retested. Sealing or tightening without a retest does not show the system is gastight.
Reference: NFPA 54 (2024), 8.1.5.3
Under IMC 801.8, what must be done with an abandoned inlet opening in a chimney or vent?
Answer: It is closed by an approved method
Section 801.8 requires abandoned inlet openings in chimneys and vents to be closed by an approved method, so the old opening cannot leak combustion products or disrupt the draft.
Reference: 2024 International Mechanical Code, Section 801.8
Two sections of the mechanical code call for different materials for the same duct application, and one is stricter. According to IMC 102.1, which governs?
Answer: The most restrictive requirement
Section 102.1 says that where a general and a specific requirement conflict, the specific one governs, and where different sections specify different materials, methods or requirements for a specific case, the most restrictive governs.
Reference: 2024 International Mechanical Code, Section 102.1
Which standard does IMC 102.3 name for the inspection of HVAC systems for maintenance?
Answer: ASHRAE/ACCA/ANSI Standard 180
Section 102.3 states that the inspection for maintenance of HVAC systems shall be performed in accordance with ASHRAE/ACCA/ANSI Standard 180. ASHRAE 15 is the refrigeration safety standard and the others cover fuel gas and controls and safety devices.
Reference: 2024 International Mechanical Code, Section 102.3
Sources
- Kirkwood Community College: Iowa state discipline exams, outlines and references (opens in a new tab)
- Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
- Iowa Administrative Code 481-429 (PMSB licensing and examination rules) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.