Requirements at a glance
| Agency | Iowa Plumbing and Mechanical Systems Board (PMSB); exam by Kirkwood Community College |
|---|---|
| Experience | 36 months of DOL apprenticeship (you may test up to 6 months before the 48 months of credit), or 4 years of experience before January 1, 2010 |
| Exam | 75 questions, 2 hours, open book; 75% to pass |
| Books allowed | 2024 International Mechanical Code and 2024 NFPA 54 National Fuel Gas Code |
| Fees | $119 to Kirkwood plus a $35 PMSB exam-candidate application per exam |
Mechanical workers applying to the Plumbing and Mechanical Systems Board for a journeyperson license: 36 months of DOL apprenticeship (you may test up to 6 months before the 48 months of credit), or 4 years of experience before January 1, 2010.
Official links
How to get licensed, step by step
Apply to the PMSB
Submit the exam-candidate application and fee to the Plumbing and Mechanical Systems Board for approval.
Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
Register with Kirkwood
Register and pay Kirkwood for your exam, then test at one of about 16 Iowa community-college centers. Fees are non-refundable and non-transferable.
Take the exam
Bring your approved references and a battery-operated, non-programmable calculator. You need 75% to pass.
Apply for your license
After you pass, send the Board a post-examination licensure application. If you fail, register and pay for a new exam (Kirkwood, 319-398-1022).
Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
How to prepare
- Kirkwood's outlines say questions are based on the listed edition, but you may bring any edition. Iowa adopted the 2024 UPC and 2024 IMC with amendments effective March 26, 2025.
- Code books may be bound or loose-leaf. Photocopies, handwritten notes and sticky notes are not allowed; highlighting and permanent tabs are.
- The exam is open book, so tab each chapter and practice finding answers fast.
- General requirements, definitions and testing is 22% and heating, refrigeration and hydronic systems 20%. Drill duct, combustion air, chimney and vent sizing and the fuel gas tables in NFPA 54.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2024 IMC and NFPA 54. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2024 International Mechanical Code (IMC), ICCEssential
Iowa's mechanical code (481 IAC 426) with Iowa amendments, effective March 26, 2025.
2024 NFPA 54 National Fuel Gas CodeEssential
Iowa's mechanical amendments point to NFPA 54 and NFPA 58 instead of the IFGC for fuel gas.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- 2024 International Mechanical Code (IMC), ICC, with Iowa amendments (481 IAC 426)
- 2024 NFPA 54 National Fuel Gas Code
What's on the exam
Official content outline from Kirkwood Community College (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Requirements, Definitions, Testing | 22 | |
| Heating, Refrigeration, and Hydronic Systems | 20 | |
| Exhaust and Ventilation Systems | 15 | |
| Duct Systems | 12 | |
| Combustion Air | 7 | |
| Chimneys and Vents | 14 | |
| Fuel Supply System | 10 |
The outline totals 100; the other items on the 75-question exam are unscored or unassigned.
Exam day details
- Administered by Kirkwood Community College for the Iowa Plumbing and Mechanical Systems Board (PMSB).
- Fee: $119 to Kirkwood per exam, plus a $35 PMSB exam-candidate application per exam. Exam fees are non-refundable and non-transferable.
- 75 questions in 2 hours (Journeyperson Mechanical with Gas); 75% to pass.
- Iowa adopted the 2024 IMC with amendments (481 IAC 426), effective March 26, 2025. For fuel gas the Iowa amendments refer to NFPA 54 and NFPA 58 (current edition) in place of the IFGC.
- Open book: bring the references listed. Code books may be bound or loose-leaf; photocopies are not allowed. You may highlight and add permanent tabs before the exam, but handwritten notes in the books are not allowed and sticky notes are not accepted.
- Exam questions are based on the listed edition, but the books you bring may be any edition.
- You may bring an architect's scale or rule and a battery-operated, non-programmable calculator with no printing capability.
- Kirkwood tests at about 16 Iowa community-college centers. Pass with 75%; then send the PMSB a post-examination licensure application. If you fail you must register and pay for a new exam.
Frequently asked questions
What's on the Iowa journeyperson mechanical exam?
75 questions: general requirements, definitions and testing 22%, heating, refrigeration and hydronic systems 20%, exhaust and ventilation 15%, chimneys and vents 14%, duct systems 12%, fuel supply 10% and combustion air 7%.
Which books are allowed?
The 2024 International Mechanical Code and the 2024 NFPA 54 National Fuel Gas Code. Any edition may be brought, but questions follow the 2024 editions.
What does it cost?
$119 to Kirkwood, plus a $35 PMSB exam-candidate application per exam.
Free questions with answers
Show all 10 free questions and answers
A single appliance is connected to a vent. Unless another provision of IMC Chapter 8 allows otherwise, what is the minimum size of the vent or chimney serving it?
Answer: An area at least equal to the area of the appliance connection
Section 801.6 sets the minimum size of a chimney or vent serving a single appliance at an area equal to the appliance connection (engineered systems excepted). Doubling the collar area is not a code rule, and neither a fixed 4-inch diameter nor the gas inlet size has any bearing on vent sizing.
Reference: 2024 International Mechanical Code, Section 801.6
A masonry chimney flue is being given a cleanout opening. The lowest chimney inlet opening is at 30 inches above the floor of the flue. Which statement meets IMC Section 801.13?
Answer: The cleanout opening is at least 6 inches high, its upper edge is at least 6 inches below the lowest inlet, and it has a tight-fitting noncombustible cover
Section 801.13 requires a cleanout at least 6 inches high, with the upper edge not less than 6 inches below the lowest chimney inlet, closed by a tight-fitting noncombustible cover. The only exception is for flues serving masonry fireplaces that are accessible through the fireplace opening.
Reference: 2024 International Mechanical Code, Section 801.13
A furnace rated 120,000 Btu/h and a water heater rated 40,000 Btu/h share one room and all combustion air will come from inside the building by the standard method. What is the minimum room volume required?
Answer: 8,000 cubic feet
The standard method needs 50 cubic feet per 1,000 Btu/h of total input. (120,000 + 40,000) / 1,000 = 160; 160 x 50 = 8,000 cu ft. Using 20 cu ft per 1,000 Btu/h gives 3,200, using only the furnace gives 6,000, and 100 cu ft per 1,000 gives 16,000.
Reference: NFPA 54 (2024), 9.3.2.1
Which plastic piping may NOT be used to supply fuel gas inside a building piping system?
Answer: PVC and CPVC
The fuel gas piping materials rules prohibit PVC and CPVC plastic pipe, tubing and fittings for fuel gas supply. Polyethylene (ASTM D2513) and polyamide (ASTM F2945) are the permitted plastics, with limits on where they may be used, and factory anodeless risers are accepted for the transition.
Reference: NFPA 54 (2024), 5.5.4.1.3
Which statement describes a transition duct that connects a clothes dryer to the dryer exhaust duct?
Answer: It is one listed length (UL 2158A) of no more than 8 feet and may not be concealed in construction
Section 504.9.3 requires transition ducts to be a single length listed and labeled to UL 2158A, not more than 8 feet long, and not concealed within construction. Longer or concealed runs belong to the rigid exhaust duct, which is sized by the duct-length rules.
Reference: 2024 International Mechanical Code, Section 504.9.3
A closet is designed to hold a clothes dryer. What is the minimum area of the opening required in the closet enclosure if makeup air is not provided by other approved means?
Answer: 100 square inches
Section 504.7 requires makeup air for installations exhausting more than 200 cfm, and for a closet designed for a dryer an opening of at least 100 square inches in the closet enclosure, unless makeup air is supplied by other approved means.
Reference: 2024 International Mechanical Code, Section 504.7
What is the maximum length of a flexible air connector, and may it pass through a wall?
Answer: 14 feet, and it may not pass through any wall, floor or ceiling
Section 603.6.2.1 limits flexible air connectors to 14 feet, and Section 603.6.2.2 prohibits them from passing through any wall, floor or ceiling. They must be listed and labeled as Class 0 or Class 1 under UL 181.
Reference: 2024 International Mechanical Code, Sections 603.6.2.1 and 603.6.2.2
Under Iowa's Section 102.12, what may a local jurisdiction do about the state mechanical code?
Answer: Administer permits and inspections, and adopt only stricter amendments
Iowa added Section 102.12: local jurisdictions may administer permit, inspection, testing and enforcement, may not adopt other mechanical codes, and may adopt additional amendments only if stricter than the state code. They must give the board copies of local amendments. The board and state do not administer those provisions unless law says otherwise.
Reference: 2024 International Mechanical Code, as amended by 481 IAC 426.3, Section 102.12 as amended by 481 IAC 426.3(2)
What is the minimum unobstructed passageway width around all sides of a boiler, unless otherwise approved?
Answer: 18 inches
Section 1004.3 requires clearances for inspection, servicing, repair and gauge visibility, with passageways around all sides of boilers not less than 18 inches wide and unobstructed, unless otherwise approved.
Reference: 2024 International Mechanical Code, Section 1004.3
A hydronic piping system has a maximum design pressure of 60 psi. What minimum hydrostatic test pressure and duration apply?
Answer: 100 psi for 15 minutes
Section 1208.1 requires hydrostatic testing at 1 1/2 times the maximum system design pressure but not less than 100 psi, for at least 15 minutes. 1.5 x 60 = 90 psi, which is below the 100 psi floor, so 100 psi governs. 90 psi forgets the floor, and 60 psi is just the design pressure.
Reference: 2024 International Mechanical Code, Section 1208.1
Sources
- Kirkwood Community College: Iowa state discipline exams, outlines and references (opens in a new tab)
- Iowa DIAL: plumbing and mechanical examination (opens in a new tab)
- Iowa Administrative Code 481-429 (PMSB licensing and examination rules) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.