Requirements at a glance
| Agency | City of Chicago Department of Buildings; exam by Continental Testing Services (CTS) |
|---|---|
| Experience | 2 years of experience when you apply online through the City of Chicago licensing portal |
| Exam | Written exam timed at 3 hours, 70 to pass; question count and book rules not published |
| Fee | $150 (CTS); not refundable |
Boiler and steam plant operators applying to the City of Chicago Department of Buildings for a stationary engineer license. You need 2 years of experience when you apply online.
Official links
How to get licensed, step by step
Create a portal account
New applications go through the City of Chicago's online licensing portal. Your name and address must match your photo ID.
Continental Testing Services: City of Chicago exams (opens in a new tab)City of Chicago Department of Buildings: trade licenses (opens in a new tab)
Register and pay by the deadline
Pay for the exam by noon on the deadline date or your registration is dropped. There are no make-up exams and no refunds.
Continental Testing Services: City of Chicago exams (opens in a new tab)
Study the CTS references
Steingress's low and high pressure boiler books and Steam Plant Operation are the CTS references.
CTS: Chicago Stationary Engineer study guide (2013) (opens in a new tab)
Pass with 70
A pass notice includes the licensure application.
CTS: Chicago Stationary Engineer study guide (2013) (opens in a new tab)
How to prepare
- CTS does not publish a question count or say whether the exam is open book; our length and closed-book setting are practice assumptions.
- Safe operation of steam boilers and controls are the largest topics at 16% each; basic principles, combustion and equipment and safety are 12% each.
- CTS's guide is from 2013; confirm the current references with CTS.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
What to study
This is a closed-book exam, so nothing comes into the exam room. Study from these:
Steingress, Low Pressure Boilers and High Pressure BoilersEssential
CTS's main references for the stationary engineer exam (Low Pressure Boilers 2nd/3rd ed; High Pressure Boilers 3rd/4th ed).
Steam Plant Operation, 8th Edition (2004)
CTS reference for steam plant operation and safety.
Official reference list (as published by the testing agency)
- Steingress, Low Pressure Boilers, 2nd Edition (2001) or 3rd Edition (2008)
- Steingress and Frost, High Pressure Boilers, 3rd Edition (2003) or 4th Edition (2008)
- Steam Plant Operation, 8th Edition (2004)
What's on the exam
Official content outline from Continental Testing Services (CTS) (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Types of Boilers | 10 | |
| Basic Principles and Units | 12 | |
| Water and Steam Properties | 7 | |
| Combustion Principles | 12 | |
| Safe Operation of Steam Boilers | 16 | |
| Controls | 16 | |
| Maintenance and Safety | 8 | |
| Equipment and Safety | 12 | |
| Fuel Combustion and Byproducts | 7 |
Exam day details
- Administered by Continental Testing Services (CTS) for the City of Chicago Department of Buildings.
- Fee: $150
- The written exam is timed at 3 hours; 70 to pass. CTS does not publish the number of questions or say whether the exam is open book, so our length is a practice setting and we assume closed book.
- Topic weights are the percentages printed in CTS's 2013 study guide; boiler operation (16%) and controls (16%) are the largest.
- New applications go through the City of Chicago's online licensing portal. Fees are not refundable and a missed exam is re-registered for the next date.
Note: CTS does not publish the question count or say whether the exam is open book, and its study guide is from 2013, so our length and closed-book setting are estimates.
Frequently asked questions
How many questions are on the Chicago stationary engineer exam?
CTS does not publish a question count. The exam is timed at 3 hours with 70 to pass.
What books does CTS recommend?
Steingress's Low Pressure Boilers and High Pressure Boilers, and Steam Plant Operation (8th edition).
What is the exam fee?
$150 for the written exam on CTS's Chicago schedule.
Free questions with answers
Show all 10 free questions and answers
In a fire-tube boiler, where are the hot combustion gases and the water located?
Answer: Hot gases flow through the tubes while water surrounds the outside of the tubes
In a fire-tube boiler the products of combustion travel inside the tubes and the tubes are submerged in the boiler water. The water-tube boiler is the reverse, with water inside the tubes and the flame and gas outside.
Reference: Steingress, Low Pressure Boilers, Types of boilers: fire-tube boilers
A steam gauge reads 85 psig at sea level. What is the absolute pressure?
Answer: 99.7 psia
Absolute pressure is gauge plus atmospheric: 85 + 14.7 = 99.7 psia. Subtracting gives 70.3, which is wrong, and the gauge reading alone omits the atmosphere. 114.7 would apply to a 100 psig gauge.
Reference: Steingress and Frost, High Pressure Boilers, Pressure: gauge and absolute
Which stack-gas reading shows an air-fuel mixture that is lean (too much air)?
Answer: High oxygen with low carbon dioxide
Excess air raises the oxygen percent and dilutes the CO2. A rich mixture shows low O2 with CO appearing in the flue gas.
Reference: Steingress and Frost, High Pressure Boilers, Combustion: flue gas analysis
What should an operator check first before lighting off a cold steam boiler?
Answer: The water level in the gauge glass
A boiler must never be fired without confirming the water is at the proper level, because firing with low water can overheat and rupture the heating surfaces. Other checks follow, but level comes first.
Reference: Steingress, Low Pressure Boilers, Operating procedures: preparing to fire
Why must no valve be placed between a boiler and its safety valve?
Answer: A closed valve would disable the relief protection
Safety valves are the last protection against overpressure, so nothing that could be closed may isolate them from the boiler. The ASME code forbids stop valves between the boiler and the safety valve or in its discharge line.
Reference: Steingress and Frost, High Pressure Boilers, Safety requirements: safety valves
What does a low-water fuel cutoff do?
Answer: Shuts off the burner when the water level falls too low
The low-water cutoff senses the level in the boiler and stops firing before the heating surfaces are uncovered. It is a safety device and is tested regularly by the operator.
Reference: Steingress, Low Pressure Boilers, Safety controls: low-water cutoff
Before closing a boiler after internal work, what must be confirmed?
Answer: That all tools, rags and people are out of the drum
Anything left inside can block circulation or cause overheating, and a person inside could be killed when the boiler is refilled. A head count and tool count is made before the manhole is closed.
Reference: Steingress, Low Pressure Boilers, Maintenance: closing up a boiler
Which problem can occur at a boiler feed pump handling hot water near its boiling point?
Answer: Cavitation, from water flashing to steam at the suction
Hot feedwater is close to boiling, so a drop in suction pressure can make bubbles that collapse and damage the impeller. Adequate suction head, a pump set below the tank, prevents it.
Reference: Steingress and Frost, High Pressure Boilers, Pumps: boiler feed pumps
Why is an odorant added to natural gas?
Answer: To make leaks detectable by smell
Natural gas is odorless, so a strong-smelling chemical (mercaptan) is added to warn people of leaks.
Reference: Steingress, Low Pressure Boilers, Fuels: natural gas
Steam is admitted quickly to a cold steam main whose drip traps have been valved off. What is the most likely result?
Answer: Condensate collects and steam drives slugs of it into fittings (water hammer)
A cold main condenses a large amount of steam during warm-up. With the drips closed the condensate cannot drain, and high-velocity steam picks up slugs of water and slams them into elbows and valves, causing water hammer that can rupture fittings. Mains are warmed slowly with drips and bypasses open.
Reference: Woodruff, Lammers and Lammers, Steam Plant Operation, Steam systems: water hammer
Sources
- Continental Testing Services (CTS): City of Chicago exams (opens in a new tab)
- City of Chicago Department of Buildings: trade licenses (opens in a new tab)
- CTS: Chicago Stationary Engineer study guide (2013) (opens in a new tab)
Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.