Idaho licensing exam

Idaho Plumbing Specialty Water Pump Journeyman Exam: Practice Test & Licensing Guide

Idaho's plumbing specialty water pump journeyman exam, given by PSI: 50 questions on the 2017 Idaho State Plumbing Code (2015 UPC), mostly general regulations and water supply. Open book, 2.5 hours, 75% to pass.

Questions
50
Time limit
2.5 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10ISPC Chapter 1: Administration

While replacing a well pump, you find the pump manufacturer's instructions call for a heavier support than the plumbing code's minimum. Under Section 102.1, which requirement governs?

Requirements at a glance

AgencyIdaho Division of Occupational and Professional Licenses (DOPL); exam by PSI
Exam50 questions, 2.5 hours, 75% to pass
Books allowed2015 Uniform Plumbing Code or 2017 Idaho State Plumbing Code
Fees$75 per exam to PSI, plus DOPL license fees

Installers applying to Idaho DOPL for a plumbing specialty journeyman license in the water pump category.

How to get licensed, step by step

  1. Check your experience

    Make sure you meet DOPL's requirements for the specialty journeyman license before you test.

    DOPL: plumbing licensing (opens in a new tab)

  2. Register and pay with PSI

    Create a PSI account, pick the Idaho Plumbing Specialty Water Pump Journeyman exam, pay the $75 fee and book a seat.

    Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)

  3. Pass the exam

    Bring your tabbed UPC or ISPC and score 75% or higher.

    Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)

How to prepare

  • Idaho is a UPC state. Don't study from IPC material.
  • Only four chapters are tested: general regulations (Chapter 3) 21, water supply and distribution (Chapter 6) 12, administration (Chapter 1) 11 and definitions (Chapter 2) 6.
  • In Chapter 6, tab backflow prevention, pressure-reducing valves, pipe materials and testing.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2015 UPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • 2015 Uniform Plumbing Code (UPC), IAPMO
  • 2017 Idaho State Plumbing Code (ISPC): the 2015 UPC as adopted with Idaho amendments (IDAPA 24.39.20)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
ISPC Chapter 1: Administration11
ISPC Chapter 2: Definitions6
ISPC Chapter 3: General Regulations21
ISPC Chapter 6: Water Supply and Distribution12

Exam day details

  • Administered by PSI Services for the Idaho Division of Occupational and Professional Licenses (DOPL).
  • Fee: $75 per exam, paid to PSI when you schedule. The fee is good for one year, isn't refundable, and each retake costs it again. DOPL license application fees are separate.
  • 50 questions in 2.5 hours; 75% to pass.
  • Open book: bring your own 2015 UPC or 2017 Idaho State Plumbing Code. Only four chapters are tested, and general regulations (Chapter 3) alone is 21 questions.
  • You may highlight, underline and add permanent tabs to your references, but not write in them. Sticky notes and loose papers aren't allowed.
  • Your score shows on screen when you finish.
  • Cancel or reschedule at least 2 days before your appointment to keep your fee.

Frequently asked questions

What's on the Idaho water pump journeyman exam?

Per DOPL's December 2025 PSI bulletin, 50 questions: general regulations (Chapter 3) 21, water supply and distribution (Chapter 6) 12, administration (Chapter 1) 11 and definitions (Chapter 2) 6.

What score do I need to pass?

75%, or 38 of the 50 questions, in 2.5 hours.

Free questions with answers

Show all 10 free questions and answers
  1. While replacing a well pump, you find the pump manufacturer's instructions call for a heavier support than the plumbing code's minimum. Under Section 102.1, which requirement governs?

    Answer: The more stringent of the two provisions

    Section 102.1 says that where the code, applicable standards or the manufacturer's installation instructions conflict, the more stringent provision prevails. The code does not automatically override instructions, and neither the date of a document nor an inspector's letter decides the conflict.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 102.1, Conflicts Between Codes

  2. A pump house was plumbed legally years before the current code was adopted and creates no hazard. The owner wants to keep using and repairing it in its original design and location. What does Section 102.2 allow?

    Answer: Its use, maintenance and repair may continue

    Section 102.2 lets plumbing systems lawfully in existence when the code was adopted continue in use, maintenance and repair, as long as the work follows the original design and location and no hazard to life, health or property has been created. There is no automatic upgrade deadline or sale trigger.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 102.2, Existing Installations

  3. A contractor will replumb a house and its detached shop, both on one lot, under one contract. How many plumbing permits does Section 104.1 call for?

    Answer: A separate permit for each building

    Section 104.1 makes it unlawful to install, alter, repair, replace or remodel a plumbing system without first obtaining a separate plumbing permit for each separate building or structure. Sharing a lot or contract does not combine them, and licensing does not exempt work from permits.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 104.1, Permits Required

  4. A cross-connection lets sewage get into a potable water line, creating an actual health hazard from disease. Which Chapter 2 term describes this impairment of the water?

    Answer: Contamination

    Chapter 2 defines contamination as an impairment of potable water quality that creates an actual hazard to public health through poisoning or the spread of disease by sewage, industrial fluids or waste (also called high hazard). Pollution is the lower-hazard impairment that affects only aesthetic quality. Backsiphonage and cross-connection describe how backflow happens, not the resulting impairment.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 205.0, Definitions: Contamination

  5. Well water reaching a house has picked up a harmless taste and color from an untreated storage tank but creates no health hazard. Which Chapter 2 term fits this low-hazard impairment?

    Answer: Pollution

    Chapter 2 defines pollution as an impairment of potable water quality that does not create a public health hazard but adversely and unreasonably affects its aesthetic qualities for domestic use; it is also called low hazard. Contamination is the high-hazard case involving poisoning or disease.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 218.0, Definitions: Pollution

  6. PEX water tubing is run through holes in wood studs, and the edge of the hole is 3/4 inch from the face of the stud. What protection does Section 312.9 require?

    Answer: A steel nail plate at least No. 18 gauge, extending 1-1/2 inches beyond the pipe

    Section 312.9 requires plastic and copper piping that penetrates framing to within 1 inch of the exposed face to be protected by steel nail plates at least No. 18 gauge (0.0478 in) thick, extending at least 1-1/2 inches beyond the outside diameter of the pipe. At 3/4 inch the pipe is inside the 1-inch zone, so a plate is required.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 312.9, Steel Nail Plates

  7. A 6-inch building drain made of a material not approved for use within a building is being laid near a house. Under Section 312.3, how close to the building may it be installed?

    Answer: No closer than 2 feet, and at least 1 foot below grade

    Section 312.3 prohibits building sewer or drainage piping of materials not approved for use under or within a building from being installed under or within 2 ft of a building or structure, or less than 1 ft below the ground surface. The other distances are not in the section.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 312.3, Building Sewer and Drainage Piping

  8. A house on a hill gets so little pressure from the public main that, after friction and elevation losses, the residual pressure at the fixtures would be about 9 psi. Under Section 608.1, what must be installed?

    Answer: A tank and pump or other means to provide at least 15 psi

    Section 608.1 requires a tank and pump or other means to provide at least 15 psi residual pressure where the source cannot do so after friction and other losses, or more where fixtures need it. A pressure-reducing valve lowers pressure, and an expansion tank only controls thermal expansion.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 608.1, Inadequate Water Pressure

  9. A 1-inch pressure regulator is installed because street pressure is 105 psi. Under Section 608.2, what else is required with the regulator?

    Answer: A strainer ahead of it, and the static pressure reduced to 80 psi or less

    Section 608.2 requires an approved regulator preceded by an adequate strainer where static pressure exceeds 80 psi, reducing static pressure to 80 psi or less. Only regulators 1-1/2 inches and larger are exempt from the strainer, so a 1-inch regulator needs one.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 608.2, Excessive Water Pressure

  10. A PVC building supply is run underground from a city meter to a house, with no electrical wiring in the trench. What tracer wire does Section 604.10.1 require?

    Answer: Blue insulated copper, at least 18 AWG, rated for direct burial

    Section 604.10.1 requires a blue insulated copper tracer wire (or other approved conductor) beside plastic building supply piping outside underground, at least 18 AWG with insulation suitable for direct burial, accessible or terminated aboveground at each end. The 14 AWG figure is the gas-piping tracer wire size (1210.1.7.2), and bonding to the grounding electrode or warning tape is not what this section requires.

    Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 604.10.1, Tracer Wire

Sources

Questions last verified October 27, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.