Requirements at a glance
| Agency | Idaho Division of Occupational and Professional Licenses (DOPL); exam by PSI |
|---|---|
| Exam | 100 points (92 one-point questions + 2 sizing problems worth 4 points), 3 hours, 70% to pass |
| Books allowed | 2015 Uniform Plumbing Code or 2017 Idaho State Plumbing Code |
| Experience | 8,000 hours plus four years of approved school, or 16,000 hours |
| Fees | $75 per exam to PSI, plus DOPL license fees |
Plumbers applying to Idaho DOPL for a journeyman plumber license. You pass the exam with PSI first, then apply to DOPL with your experience (8,000 hours plus four years of approved school, or 16,000 hours).
Official links
How to get licensed, step by step
Build your hours
Build 8,000 hours of plumbing experience plus four years of approved schooling, or 16,000 hours of experience.
Register and pay with PSI
Create a PSI account, pick the Idaho Plumbing Journeyman exam, pay the $75 fee and book a seat. Cancel or reschedule at least 2 days ahead to keep the fee.
Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)
Pass the exam
Bring your tabbed UPC or ISPC. Your score shows on screen and goes to DOPL.
Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)
Apply to DOPL
After you pass, apply through eDOPL with your experience; DOPL contacts you to collect the license fee.
DOPL online license application (eDOPL) (opens in a new tab)DOPL: plumbing licensing (opens in a new tab)
How to prepare
- Idaho is a UPC state. Don't study from IPC material: fixture units, vent sizing and many clearances differ.
- Water supply (Ch. 6) and drainage (Ch. 7) are 11 questions each, and water heaters (Ch. 5) and vents (Ch. 9) 10 each: tab the sizing tables in all four.
- The two sizing problems are worth 4 points each. Practice sizing a water supply and a drainage system from a riser diagram with the UPC tables.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2015 UPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2015 Uniform Plumbing Code (UPC) or 2017 Idaho State Plumbing CodeEssential
Bring one. Idaho adopted the 2015 UPC with amendments as its plumbing code, so the numbering matches. Tab Chapters 5, 6, 7, 9 and 12 and the sizing tables.
IAPMO store (opens in a new tab)Read free (IAPMO) (opens in a new tab)
Official reference list (as published by the testing agency)
- 2015 Uniform Plumbing Code (UPC), IAPMO
- 2017 Idaho State Plumbing Code (ISPC): the 2015 UPC as adopted with Idaho amendments (IDAPA 24.39.20)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| ISPC Chapter 1: Administration | 5 | |
| ISPC Chapter 2: Definitions | 5 | |
| ISPC Chapter 3: General Regulations | 5 | |
| ISPC Chapter 4: Plumbing Fixtures and Fixture Fittings | 5 | |
| ISPC Chapter 5: Water Heaters | 10 | |
| ISPC Chapter 6: Water Supply and Distribution | 11 | |
| ISPC Chapter 7: Sanitary Drainage | 11 | |
| ISPC Chapter 8: Indirect Wastes | 6 | |
| ISPC Chapter 9: Vents | 10 | |
| ISPC Chapter 10: Traps and Interceptors | 7 | |
| ISPC Chapter 11: Storm Drainage | 4 | |
| ISPC Chapter 12: Fuel Gas Piping | 8 | |
| ISPC Chapter 14: Firestop Protection | 1 | |
| ISPC Chapter 15: Alternate Water Sources for Nonpotable Applications | 2 | |
| ISPC Chapter 16: Nonpotable Rainwater Catchment Systems | 1 | |
| ISPC Chapter 17: Referenced Standards | 1 | |
| Plumbing Sizing from Schematics | 2 |
Exam day details
- Administered by PSI Services for the Idaho Division of Occupational and Professional Licenses (DOPL).
- Fee: $75 per exam, paid to PSI when you schedule. The fee is good for one year, isn't refundable, and each retake costs it again. DOPL license application fees are separate.
- 100 points in 3 hours; 70% to pass. 92 questions are worth 1 point each and 2 plumbing sizing problems, worked from schematics handed out at the exam, are worth 4 points each.
- Open book: bring your own 2015 UPC or 2017 Idaho State Plumbing Code. Idaho adopted the 2015 UPC (with Appendices A, B, C, D, E, G, I, J, K and L) as its plumbing code, with Idaho amendments, so section numbers match the UPC.
- Pass the exam with PSI first, then apply to DOPL. Scores go to DOPL directly, and DOPL contacts you to finish the license.
- You may highlight, underline and add permanent tabs to your references, but not write in them. Sticky notes and loose papers aren't allowed.
- Your score shows on screen when you finish.
- Cancel or reschedule at least 2 days before your appointment to keep your fee.
Frequently asked questions
What's on the Idaho journeyman plumber exam?
Per DOPL's December 2025 PSI bulletin: water supply and distribution 11, sanitary drainage 11, water heaters 10, vents 10, fuel gas piping 8, traps and interceptors 7, indirect wastes 6, administration, definitions, general regulations and fixtures 5 each, storm drainage 4, alternate water sources 2, firestop, rainwater catchment and referenced standards 1 each, plus 2 sizing problems worth 4 points each.
Which code book do I bring to the Idaho plumbing exam?
The 2015 Uniform Plumbing Code or the 2017 Idaho State Plumbing Code (the 2015 UPC with Idaho amendments). Not the International Plumbing Code: Idaho is a UPC state.
What score do I need to pass?
70% (70 of 100 points) in 3 hours. An older DOPL-run bulletin listed 75%, but the current PSI bulletin says 70.
Free questions with answers
Show all 10 free questions and answers
Idaho's rule adopting the plumbing code (IDAPA 24.39.20.600) replaces Section 105.3, Testing of Systems. According to that replacement text, plumbing systems must be tested and approved in accordance with what?
Answer: The plumbing code or the Authority Having Jurisdiction
Idaho's amended Section 105.3 says plumbing systems must be tested and approved in accordance with the code or the Authority Having Jurisdiction (AHJ). The AHJ may conduct the tests in person or through a duly appointed representative. The contractor or manufacturer does not set the test standard on their own.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Idaho amendment to 2015 UPC (IDAPA 24.39.20.600), Section 105.3
A separate vertical pipe runs alongside a drainage stack and is installed mainly to circulate air to and from the drainage system, with connections to the stack at the lower floors. What is this pipe called?
Answer: A vent stack
A vent stack is a vertical vent pipe installed primarily to provide air circulation to and from any part of the drainage system. A stack vent, in contrast, is simply the extension of the soil or waste stack above its highest horizontal connection.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 224.0, Definitions: Vent Stack
A plumber hangs horizontal solvent-cemented Schedule 40 PVC drain pipe in a crawl space. What is the maximum support spacing in the hanger table?
Answer: 4 feet
Table 313.3 requires horizontal ABS and PVC DWV pipe to be supported every 4 ft, with a way to handle expansion in long runs. The 6-ft figure is the horizontal spacing for small copper tube, and 10 ft is for copper 2 in and larger.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Table 313.3, Hangers and Supports
Which description fits a code-compliant discharge pipe from a water heater's temperature and pressure relief valve?
Answer: Full size of the valve outlet, no valves or traps, draining by gravity
The T&P discharge pipe must be at least the size of the valve outlet, run full size to its termination, drain by gravity, and have no valves, traps or threaded end connections that could be capped. Trapping or reducing it could block relief when it is needed.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 608.5, Discharge Piping
A new copper water distribution system is pressure tested with air instead of water. What is the minimum air test pressure and duration?
Answer: 50 psi for 15 minutes
Section 609.4 requires the water supply system to be tested with water at not less than its working pressure, or with a 50 psi air test, and the piping must hold for at least 15 minutes without leaking. Idaho deletes the model code's "Except for plastic piping" limit on the air test and adds that plastic piping is tested per the manufacturer's standards. The 5 psi figure is the drain-waste-vent air test.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 609.4, Testing (as amended by IDAPA 24.39.20.600)
What is the minimum slope for horizontal drainage piping 3 inches in diameter?
Answer: 1/4 inch per foot
Horizontal drainage piping must be installed at a uniform slope of not less than 1/4 inch per foot (2 percent) toward the point of disposal. A lesser slope is allowed only for larger pipe, where the AHJ approves it because the sewer depth or structure makes 1/4 in impractical.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 708.1, General (Grade of Horizontal Drainage Piping)
A restaurant installs a reach-in refrigerator, a walk-in cooler evaporator coil and a coffee brewer. How must the drains from these units be connected to the sanitary drainage system?
Answer: Indirectly, through an air gap or air break into a trapped receptor
Section 801.3 requires indirect waste piping for refrigerators, refrigeration coils, walk-in coolers, coffee urns and brewers and similar food and beverage equipment, and Section 801.2 says indirect waste discharges through an air gap or air break into the drainage system. A direct connection with only a trap would let sewage back up into the food equipment.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Sections 801.2 and 801.3, Indirect Wastes (Food and Beverage Handling Establishments)
A lavatory has a 1-1/2-inch trap arm. The vent connection is measured 50 inches along the trap arm from the trap weir. Is this arrangement permitted?
Answer: No; the maximum trap arm length for 1-1/2 inch is 42 inches (3 ft 6 in)
The trap arm table allows 3 ft 6 in (42 in) for a 1-1/2 in trap arm, 5 ft (60 in) for 2 in. At 50 inches this lavatory is 8 inches too far from its vent. Upsizing the trap arm to 2 inches would fix it, since 50 inches is under 60.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 1002.2 and Table 1002.2, Horizontal Lengths of Trap Arms
What liquid seal depth is required for an ordinary fixture trap?
Answer: At least 2 inches and not more than 4 inches
Fixture traps must have a liquid seal of not less than 2 inches and not more than 4 inches. A shallower seal is lost to evaporation or siphonage too easily, and a deeper seal slows the trap's scouring action.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 1005.1, General (Trap Seals)
A new gas furnace has no built-in sediment trap. Where must a sediment trap be installed in the gas supply?
Answer: Downstream of the appliance shutoff, as close to the inlet as practical
Section 1212.8 requires a sediment trap, where one is not built into the appliance, downstream of the appliance shutoff valve, as close to the appliance inlet as practical and before any flexible connector. It is usually a tee with a capped nipple in the bottom outlet. A trap at the meter or inside the cabinet after the gas valve would not protect the controls.
Reference: 2015 Uniform Plumbing Code (2017 Idaho State Plumbing Code), Section 1212.8, Sediment Trap
Sources
- Idaho DOPL: Combined PSI Candidate Bulletin (effective 12.10.2025, PDF) (opens in a new tab)
- Idaho DOPL: Plumbing licensing (opens in a new tab)
- PSI: Idaho contractor and trade exams (candidate bulletins) (opens in a new tab)
Questions last verified October 27, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.