Requirements at a glance
| Agency | Idaho Division of Occupational and Professional Licenses (DOPL); exam by PSI |
|---|---|
| Exam | 100 questions, 4.5 hours, 75% to pass |
| Books allowed | 2020 or 2023 NEC (or NEC Handbook) and Ugly's Electrical References (any edition) |
| Fees | $75 per exam to PSI, plus DOPL license application fees |
Journeyman electricians applying to Idaho DOPL for a master electrician license. You pass the exam with PSI first, then apply to DOPL with your experience.
Official links
How to get licensed, step by step
Check your experience
Make sure you meet DOPL's experience requirements for the master electrician license before you test; you prove them when you apply.
DOPL: electrical program information and exams (opens in a new tab)
Register and pay with PSI
Create a PSI account, pick the Idaho exam and pay the $75 fee. Acceptance is automatic, then schedule a seat at a PSI center. The fee is good for one year.
Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)
Pass the exam
Bring your tabbed references and a silent, non-programmable calculator.
Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)DOPL notice: electrical exams move to PSI (June 2024) (opens in a new tab)
Apply to DOPL
After you pass, create an eDOPL account and apply for the master electrician license with your experience.
DOPL online license application (eDOPL) (opens in a new tab)
How to prepare
- Bring your own 2020 or 2023 NEC (or NEC Handbook) and Ugly's (any edition). The PSI bulletin bases code questions only on those NEC editions.
- Tab your books before exam day with permanent tabs. You can highlight and underline, but not write in them; sticky notes are removed.
- Wiring and protection (25), wiring methods (20) and equipment for general use (20) are two thirds of the exam; equipment adds motors (430), transformers (450) and panelboards (408).
- Special occupancies (11), special equipment (6), special conditions (5) and communication systems (3) add 25 questions from Chapters 5 to 8. You need 75%, so don't skip them.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2020 or 2023 Edition (or the NEC Handbook)Essential
Bring your own; code questions are based only on these editions. Tab Articles 90, 100, 110, 210 to 250, 300 to 392, 430, 450, 500 to 517 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC) or NEC Handbook, 2020 or 2023 Edition
- Ugly's Electrical References (any edition)
- Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index (2020 and 2023 editions)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 10 | |
| Wiring and Protection | 25 | |
| Wiring Methods and Materials | 20 | |
| Equipment for General Use | 20 | |
| Special Occupancies | 11 | |
| Special Equipment | 6 | |
| Special Conditions | 5 | |
| Communication Systems | 3 |
Exam day details
- Administered by PSI Services for the Idaho Division of Occupational and Professional Licenses (DOPL).
- Fee: $75 per exam, paid to PSI when you schedule. The fee is good for one year, isn't refundable, and each retake costs it again. DOPL license application fees are separate.
- 100 questions in 4.5 hours; 75% to pass.
- Open book: bring your own 2020 or 2023 NEC (or NEC Handbook) and Ugly's Electrical References (any edition). Code questions use only those NEC editions.
- Pass the exam with PSI first, then apply to DOPL for the license with your experience. Book online at PSI; no DOPL approval is needed to sit.
- A silent, non-programmable, non-printing calculator is allowed.
- You may highlight, underline and add permanent tabs to your references, but not write in them. Sticky notes and loose papers aren't allowed.
- Your score shows on screen when you finish.
- Cancel or reschedule at least 2 days before your appointment to keep your fee.
Frequently asked questions
What's on the Idaho master electrician exam?
Per DOPL's December 2025 PSI bulletin, 100 questions: wiring and protection 25, wiring methods and materials 20, equipment for general use 20, special occupancies 11, general electrical knowledge 10, special equipment 6, special conditions 5 and communication systems 3.
What score do I need to pass the Idaho master electrician exam?
75%, or 75 of the 100 questions, in 4.5 hours. The journeyman exam has the same length, time and passing score.
Is the Idaho master exam the same as the electrical contractor exam?
No. The master electrician exam is the NEC trade exam. Idaho's Electrical Contractor exam is a separate 100-question business and law exam on DOPL's Contractor's Business and Law Reference Manual, also given by PSI.
Free questions with answers
Show all 10 free questions and answers
A 3-phase feeder serves 96 A of continuous load and 40 A of noncontinuous load. No ampacity correction or adjustment factors apply. What is the minimum ampacity required for the feeder ungrounded conductors?
Answer: 160 A
Section 215.2(A)(1) requires 125% of the continuous load plus 100% of the noncontinuous load: 96 x 1.25 = 120 A, plus 40 A = 160 A. 136 A simply adds the loads, 170 A applies 125% to the entire 136 A, and 120 A ignores the noncontinuous portion.
Reference: NFPA 70, National Electrical Code, 2023, 215.2(A)(1)
A 3-phase, 460-volt, 25-hp induction motor has a nameplate full-load current of 31 A. What is the minimum ampacity of the branch-circuit conductors for this continuous-duty motor?
Answer: 42.5 A
Section 430.22 requires conductors of at least 125% of the motor full-load current, and 430.6(A)(1) says to use the Table 430.250 value (34 A for 25 hp at 460 V), not the nameplate: 34 x 1.25 = 42.5 A. 38.8 A uses the nameplate, 34 A has no 125%, and 35.7 A uses 115% of the nameplate.
Reference: NFPA 70, National Electrical Code, 2023, 430.6(A)(1), 430.22, Table 430.250
A balanced 3-phase, 480-volt load draws 75 kW at a power factor of 0.85. What is the line current?
Answer: 106 A
For a 3-phase load, I = P / (1.732 x E x PF) = 75,000 / (1.732 x 480 x 0.85) = 106 A. 90 A ignores the power factor, 184 A uses the single-phase formula without 1.732, and 133 A adds an unneeded 125% factor to the correct current.
Reference: General electrical theory, Three-phase power and power factor
How must the phases be arranged on the buses of a 3-phase panelboard under 408.3(E)?
Answer: A, B, C from front to back, top to bottom, or left to right
Section 408.3(E) requires the phase arrangement on 3-phase buses to be A, B, C from front to back, top to bottom, or left to right, as viewed from the front of the panelboard. The other choices describe reversed or unspecified arrangements; on a 4-wire delta, the high leg is the B phase.
Reference: NFPA 70, National Electrical Code, 2023, 408.3(E)
When equipment or installation instructions give a torque value for a terminal, what does 110.14(D) require?
Answer: The indicated torque value must be achieved, such as with a calibrated torque tool
Wherever a tightening torque is marked on the equipment or given in the manufacturer's instructions, 110.14(D) requires that value to be achieved with a proper method. The 2020 NEC says an approved means shall be used (its informational note lists calibrated torque tools); the 2023 NEC requires a calibrated torque tool unless the manufacturer provides an alternative method. Either way, 'feels tight' is not acceptable, and the rule applies to all terminal sizes, not just large ones.
Reference: NFPA 70, National Electrical Code, 2023, 110.14(D)
What does 110.12(A) require for unused openings in boxes, raceways, cabinets and enclosures?
Answer: They must be closed to give protection equal to the equipment wall
Section 110.12(A) requires unused openings, other than those intended for the operation of the equipment or for mounting, to be effectively closed to provide protection substantially equivalent to the wall of the equipment. Location above a ceiling or in a dry area does not change the rule.
Reference: NFPA 70, National Electrical Code, 2023, 110.12(A)
Where must the disconnecting means for a sign or outline lighting system be located under 600.6(A)?
Answer: Within sight of the sign it controls, or lockable in the open position if it is not
Section 600.6(A) requires each sign and outline lighting system to have an externally operable disconnecting means within sight of the sign it controls. Where the disconnect is out of line of sight from any section that can be energized, it must be capable of being locked in the open position. A label alone or a disconnect inside the sign is not acceptable.
Reference: NFPA 70, National Electrical Code, 2023, 600.6(A)
Several conductors are to be installed through a Class I conduit seal fitting that is not specifically identified for a higher percentage. Under the conductor-fill rule for seals in 501.15(C), what is the maximum fill, as a percentage of the cross-sectional area of rigid metal conduit of the same trade size?
Answer: 25 percent
The conductor-fill rule for sealing fittings in 501.15(C) limits the conductors or optical fiber tubes in a seal to 25 percent of the cross-sectional area of rigid metal conduit of the same trade size, unless the seal is specifically identified for a higher percentage. (501.15(C)(3) covers the thickness of the sealing compound, not fill.) The 31 percent, 40 percent and 53 percent values are the Chapter 9, Table 1 conduit fill limits for two, three or more, and one conductor, which do not govern seals. The rule is the same in the 2020 and 2023 NEC.
Reference: NFPA 70, National Electrical Code, 2023, 501.15(C)
A 24-volt Class 2 thermostat cable must enter a device box that also holds 120-volt switch conductors. What does 725.136 generally require?
Answer: A barrier that separates the Class 2 conductors from the power conductors in the box
Section 725.136(A) prohibits Class 2 and Class 3 conductors in the same enclosure, cable or raceway as electric light, power or Class 1 conductors unless a permitted exception applies; 725.136(B) permits them in the same enclosure where they are separated by a barrier. Voltage class or conductor size does not remove the requirement. The section number and rule are the same in the 2020 and 2023 NEC.
Reference: NFPA 70, National Electrical Code, 2023, 725.136(A), 725.136(B)
A communications grounding electrode conductor is installed in a metal raceway for physical protection. What does 800.100(A) require for the raceway?
Answer: Both ends of the raceway must be bonded to the conductor, or to the same terminal or electrode
Where a communications bonding conductor or grounding electrode conductor is installed in a metal raceway, both ends of the raceway must be bonded to the contained conductor or to the same terminal or electrode to which the conductor is connected (800.100(A)). An unbonded raceway acts as a choke that raises the impedance to lightning surges. The requirement is the same in the 2020 and 2023 NEC.
Reference: NFPA 70, National Electrical Code, 2023, 800.100(A)
Sources
- Idaho DOPL: Combined PSI Candidate Bulletin (effective 12.10.2025, PDF) (opens in a new tab)
- Idaho DOPL: Electrical program information and exams (opens in a new tab)
- Idaho DOPL notice: electrical exams move to PSI (June 2024) (opens in a new tab)
Questions last verified October 27, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.