Requirements at a glance
| Agency | Idaho Division of Occupational and Professional Licenses (DOPL); exam by PSI |
|---|---|
| Exam | 100 questions, 4.5 hours, 75% to pass |
| Books allowed | 2020 or 2023 NEC (or NEC Handbook) and Ugly's Electrical References (any edition) |
| Fees | $75 per exam to PSI, plus DOPL license application fees |
Electricians applying to Idaho DOPL for a journeyman electrician license. You pass the exam with PSI first, then apply to DOPL with your experience.
Official links
How to get licensed, step by step
Check your experience
Make sure you meet DOPL's experience requirements for the journeyman electrician license before you test; you prove them when you apply.
DOPL: electrical program information and exams (opens in a new tab)
Register and pay with PSI
Create a PSI account, pick the Idaho exam and pay the $75 fee. Acceptance is automatic, then schedule a seat at a PSI center. The fee is good for one year.
Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)
Pass the exam
Bring your tabbed references and a silent, non-programmable calculator.
Schedule with PSI (Idaho contractor and trade exams) (opens in a new tab)DOPL notice: electrical exams move to PSI (June 2024) (opens in a new tab)
Apply to DOPL
After you pass, create an eDOPL account and apply for the journeyman electrician license with your experience.
DOPL online license application (eDOPL) (opens in a new tab)
How to prepare
- Bring your own 2020 or 2023 NEC (or NEC Handbook) and Ugly's (any edition). The PSI bulletin bases code questions only on those NEC editions.
- Tab your books before exam day with permanent tabs. You can highlight and underline, but not write in them; sticky notes are removed.
- Wiring and protection (25), wiring methods and materials (19) and equipment for general use (19) are almost two thirds of the exam: tab Articles 200 to 250, 300 to 392 and 400 to 490 plus Chapter 9.
- General electrical knowledge (13) covers Articles 90, 100 and 110 and the theory in Ugly's: Ohm's law, series and parallel circuits.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2020 or 2023 Edition (or the NEC Handbook)Essential
Bring your own; code questions are based only on these editions. Tab Articles 90, 100, 110, 210 to 250, 300 to 392, 430, 450, 500 to 517 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC) or NEC Handbook, 2020 or 2023 Edition
- Ugly's Electrical References (any edition)
- Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index (2020 and 2023 editions)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 13 | |
| Wiring and Protection | 25 | |
| Wiring Methods and Materials | 19 | |
| Equipment for General Use | 19 | |
| Special Occupancies | 12 | |
| Special Equipment | 6 | |
| Special Conditions | 6 |
Exam day details
- Administered by PSI Services for the Idaho Division of Occupational and Professional Licenses (DOPL).
- Fee: $75 per exam, paid to PSI when you schedule. The fee is good for one year, isn't refundable, and each retake costs it again. DOPL license application fees are separate.
- 100 questions in 4.5 hours; 75% to pass.
- Open book: bring your own 2020 or 2023 NEC (or NEC Handbook) and Ugly's Electrical References (any edition). Code questions use only those NEC editions.
- Pass the exam with PSI first, then apply to DOPL for the license with your experience. Book online at PSI; no DOPL approval is needed to sit.
- A silent, non-programmable, non-printing calculator is allowed.
- You may highlight, underline and add permanent tabs to your references, but not write in them. Sticky notes and loose papers aren't allowed.
- Your score shows on screen when you finish.
- Cancel or reschedule at least 2 days before your appointment to keep your fee.
Frequently asked questions
What's on the Idaho journeyman electrician exam?
Per DOPL's December 2025 PSI bulletin, 100 questions: wiring and protection 25, wiring methods and materials 19, equipment for general use 19, general electrical knowledge 13, special occupancies 12, special equipment 6 and special conditions 6.
Which NEC edition can I bring to the Idaho electrical exam?
DOPL's December 2025 PSI bulletin allows the 2020 or 2023 NEC (or the NEC Handbook), and code questions use only those editions. Ugly's Electrical References (any edition) is also allowed. Check the current PSI bulletin before you buy a book.
Who gives the Idaho electrical exam?
PSI, since June 2024. You register and pay PSI directly, take the exam at a PSI center, and apply to DOPL for the license after you pass.
Free questions with answers
Show all 10 free questions and answers
A 240-volt heating element has a resistance of 15 ohms. What current does it draw?
Answer: 16 A
Ohm's law: I = E / R = 240 / 15 = 16 A. 3,600 comes from multiplying 240 x 15, 225 is 15 squared, and 0.06 is 15 / 240 (the ratio inverted).
Reference: General electrical theory, Ohm's law
A 3-phase, 480-volt motor load draws 50 A at a power factor of 0.80. What is the apparent power of the load?
Answer: 41.6 kVA
Apparent power S = 1.732 x E x I = 1.732 x 480 x 50 = 41,568 VA, or 41.6 kVA. Multiplying by the 0.80 power factor gives true power of 33.3 kW, which is not apparent power.
Reference: General electrical theory, kVA, kW and power factor
A 40-ampere branch circuit will be wired with copper THHN conductors to equipment whose terminals are not marked with a temperature rating. Using the NEC ampacity table for not more than three current-carrying conductors in a raceway, what is the smallest conductor permitted?
Answer: 8 AWG
For circuits of 100 A or less with unmarked terminals, 110.14(C)(1)(a)(1) limits the conductor ampacity to the 60 C column of Table 310.16 (same number and values in the 2020 NEC). In the 60 C column, 8 AWG is 40 A. Ten AWG THHN is 40 A only in the 90 C column, which cannot be used for terminating at unmarked equipment.
Reference: NFPA 70, National Electrical Code, 2023, 110.14(C)(1)(a)(1); Table 310.16
Under Table 300.5, what is the minimum cover for rigid metal conduit buried in a location not specifically addressed in the table (such as a lawn area)?
Answer: 6 in
Table 300.5 gives 6 in of minimum cover for rigid metal conduit and intermediate metal conduit in all locations not specified separately. PVC conduit needs 18 in in the same location and 24 in under roads and parking lots.
Reference: NFPA 70, National Electrical Code, 2023, Table 300.5
Five current-carrying 10 AWG THHN copper conductors are installed in one EMT where the ambient temperature is 43 C (110 F). The 90 C table ampacity is 40 A, the ambient temperature correction factor is 0.87, and the NEC adjustment factor for 4 to 6 current-carrying conductors applies. What is the adjusted ampacity of each conductor?
Answer: 27.8 A
Four to six current-carrying conductors in a raceway require an 80% adjustment (Table 310.15(C)(1)). Adjusted ampacity = 40 A x 0.87 x 0.80 = 27.8 A. The 2020 NEC calls the ambient correction table 310.15(B)(1); the values are the same. Leaving off the adjustment factor yields 34.8 A, and applying only the 80% factor yields 32.0 A.
Reference: NFPA 70, National Electrical Code, 2023, Table 310.16; Table 310.15(B)(1)(1); Table 310.15(C)(1)
A recessed luminaire that is not identified as Type IC is installed in an insulated ceiling. Under 410.116, how close may thermal insulation be placed to the luminaire enclosure, wiring compartment or ballast?
Answer: No closer than 3 in
410.116(B) prohibits thermal insulation above a recessed luminaire or within 3 in of its enclosure, wiring compartment, ballast, transformer, LED driver or power supply unless the luminaire is identified as Type IC. A Type IC luminaire may be in contact with insulation.
Reference: NFPA 70, National Electrical Code, 2023, 410.116(B)
A single 20 hp, 460-volt, 3-phase induction motor has a full-load current of 27 A in Table 430.250. Under 430.22, what is the minimum ampacity of the branch-circuit conductors for this continuous-duty motor?
Answer: 33.8 A
430.22 requires branch-circuit conductors for a single continuous-duty motor to be rated at least 125% of the full-load current taken from the table: 27 x 1.25 = 33.75, or 33.8 A. 67.5 A is the 250% figure used for the inverse time breaker rating.
Reference: NFPA 70, National Electrical Code, 2023, 430.22, Table 430.250
Under Article 500, which class applies to a location that is hazardous because of ignitable fibers or flyings, such as in a textile mill, that are not likely to be suspended in air in quantities that produce ignitable mixtures?
Answer: Class III
500.5(D) defines Class III locations as hazardous because of the presence of easily ignitable fibers or flyings. Class I covers flammable gases or vapors, and Class II covers combustible dust. There is no Class IV in the NEC.
Reference: NFPA 70, National Electrical Code, 2023, 500.5(D)
What is the minimum size of the equipotential bonding conductor for a permanently installed swimming pool, if a solid copper conductor is used?
Answer: 8 AWG
680.26(B) requires the parts listed there to be bonded together with a solid copper conductor, insulated, covered or bare, not smaller than 8 AWG (or rigid metal conduit of brass or other identified corrosion-resistant metal). Smaller conductors are not permitted.
Reference: NFPA 70, National Electrical Code, 2023, 680.26(B)
Under Article 701, a legally required standby system must be able to supply power within what maximum time after loss of the normal source?
Answer: 60 seconds
701.12 requires legally required standby power to be available within 60 seconds of loss of normal power. Emergency systems under Article 700 have the stricter 10-second limit.
Reference: NFPA 70, National Electrical Code, 2023, 701.12
Sources
- Idaho DOPL: Combined PSI Candidate Bulletin (effective 12.10.2025, PDF) (opens in a new tab)
- Idaho DOPL: Electrical program information and exams (opens in a new tab)
- Idaho DOPL notice: electrical exams move to PSI (June 2024) (opens in a new tab)
Questions last verified October 27, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.