Requirements at a glance
| Agency | Hawaii Board of Electricians and Plumbers (DCCA PVL); exams by PSI |
|---|---|
| Experience | Age 18 or older, 3 years (at least 6,000 hours) in the trade under a journey worker, supervising or specialty electrician, and 120 hours of electrical coursework accepted by a University of Hawaii community college (HRS 448E-5(b)) |
| Exam | Journey worker specialty electrician: 50 questions, 2 hours, 70% |
| Books allowed | None; the 2020 NEC is provided in the exam center |
| Fee | $95 to PSI, plus the Board's application and license fees |
Electrical workers applying for a Hawaii journey worker specialty electrician license, covering electronic equipment, sound and communication systems, antenna systems, burglar and fire alarm systems and low voltage remote control and signal systems (not the attachment of lighting and power circuits).
Official links
How to get licensed, step by step
Apply to the Board
Send the Board of Electricians and Plumbers your application with proof of your experience. You can't register with PSI until it approves you.
Board of Electricians and Plumbers (opens in a new tab)Hawaii Revised Statutes chapter 448E (electricians and plumbers) (opens in a new tab)Hawaii Administrative Rules 16-80 (electricians and plumbers) (opens in a new tab)
Schedule the journey worker specialty electrician exam with PSI
Register online or call PSI at 833-333-4754. Your approval is good for 2 years and you can test as often as you like in that time.
Get licensed
PSI reports your result to the Board; follow the Board's instructions for the license fee and any remaining requirements.
How to prepare
- Hawaii's trade exams are PSI exams on specific editions: the 2020 NEC, the 2018 UPC, IMC, IFGC and IBC. Hawaii's state electrical code is older than the 2020 NEC, so study to the editions on PSI's bulletin, and check the bulletin again before test day.
- Contractor exams are closed book except C-13, where PSI provides the NEC. Electrician exams provide the NEC too. Plumber and other contractor exams allow no reference books.
- Fire detection and alarm, intrusion detection and alarm, and low voltage and communication circuits are 10 questions each, 30 of the 50.
- Look at NEC Articles 760 (fire alarm and power-limited circuits), 725 (Class 1, 2 and 3 circuits) and Chapter 8 (communications).
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2020 National Electrical Code (NEC), NFPA 70Essential
Provided in the exam center, so you can't bring your own. Practice finding answers fast.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code, 2020 edition (provided in the exam center)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 8 | |
| Service, Feeders, and Branch Circuits | 2 | |
| Grounding and Bonding | 4 | |
| Conductors and Cables | 2 | |
| Special Occupancies, Conditions, and Equipment | 2 | |
| Fire Detection and Alarm Systems | 10 | |
| Intrusion Detection and Alarm Systems | 10 | |
| Low Voltage and Communication Circuits | 10 | |
| Safety Information | 2 |
Exam day details
- Administered by PSI Services for the Hawaii Board of Electricians and Plumbers.
- Fee: $95 to PSI. Board application and license fees are separate.
- 50 scored questions in 2 hours; 35 correct (70%) to pass.
- The Board must approve your application before you can register with PSI. Your eligibility lasts 2 years, and you can test as often as you like within it.
- PSI may add up to 10 unscored pretest questions; they do not count against your time.
- PSI provides an online calculator, or you can bring a silent, non-programmable one.
Frequently asked questions
What's on the Hawaii specialty electrician exam?
50 scored questions: fire detection and alarm systems 10, intrusion detection and alarm systems 10, low voltage and communication circuits 10, general electrical knowledge 8, grounding and bonding 4, service, feeders and branch circuits 2, conductors and cables 2, special occupancies 2 and safety information 2.
Which NEC edition is used?
The 2020 NEC, provided in the exam center.
What work does the specialty license cover?
Installing, repairing, altering and maintaining (but not attaching lighting and power circuits to) electronic, sound, communication, antenna, burglar and fire alarm, low voltage remote control and signal systems, other than those in single-family or two-family dwellings where the statute says so.
Free questions with answers
Show all 10 free questions and answers
Which NEC article covers the installation of wiring and equipment for fire alarm systems, including circuits that the fire alarm system itself controls and powers?
Answer: Article 760, Fire Alarm Systems
Section 760.1 gives the scope of Article 760: wiring and equipment of fire alarm systems, including all circuits controlled and powered by the fire alarm system. Article 725 covers other signaling and power-limited circuits, and Chapter 8 covers communications.
Reference: NFPA 70 National Electrical Code, 2020 edition, 760.1
Which marking is required on the disconnecting means for a fire alarm branch circuit?
Answer: Red identification and the words FIRE ALARM CIRCUIT
Section 760.121(B) requires the fire alarm branch-circuit disconnecting means to have red identification, be accessible only to qualified personnel, and be identified as FIRE ALARM CIRCUIT. The red marking may not damage the overcurrent device or hide the manufacturer's markings.
Reference: NFPA 70 National Electrical Code, 2020 edition, 760.121(B)
Several normally closed door contacts are wired in series on one burglar alarm zone. What causes that zone to go into alarm?
Answer: Any one contact opening the circuit
A series loop of normally closed devices is a continuous path while every door is shut. Opening any one contact (or cutting a wire) breaks the loop and the control panel sees an open zone. Normally open devices, by contrast, go in parallel.
Reference: General practice (electronic security systems), Zone wiring: normally closed series loops
What is the smallest permitted size for the bonding conductor or grounding electrode conductor of a communications primary protector?
Answer: 14 AWG
Section 800.100(A)(3) requires the bonding conductor or grounding electrode conductor to be not smaller than 14 AWG, with current-carrying capacity at least equal to that of the protected conductors, and not required to exceed 6 AWG.
Reference: NFPA 70 National Electrical Code, 2020 edition, 800.100(A)(3)
A 24-volt notification circuit has 12 appliances at 0.075 A each, 200 ft from the panel (one-way), on 16 AWG wire of 4.0 ohms per 1,000 ft. What is the voltage drop?
Answer: About 1.44 V
Current = 12 x 0.075 = 0.9 A. Round-trip length = 2 x 200 = 400 ft, so R = 4.0 x 400 / 1,000 = 1.6 ohms. Vd = 0.9 x 1.6 = 1.44 V (6 percent of 24 V). 0.72 V uses one-way length, 1.60 V is the resistance, and 3.60 V uses 1,000 ft of resistance.
Reference: General practice (electronic security systems), Voltage drop
A service uses 3/0 AWG copper ungrounded conductors. What is the minimum copper grounding electrode conductor size from Table 250.66?
Answer: 4 AWG
Table 250.66 gives 8 AWG for copper service conductors 2 AWG or smaller, 6 AWG for 1 or 1/0, 4 AWG for 2/0 or 3/0, and 2 AWG for over 3/0 through 350 kcmil. So 3/0 copper needs a 4 AWG GEC (subject to 250.66(A) through (C) limits).
Reference: NFPA 70 National Electrical Code, 2020 edition, Table 250.66
From the 75 degree C column of the table for allowable ampacities, what is the ampacity of a 12 AWG copper conductor, before the small-conductor limits of 240.4(D)?
Answer: 25 amperes
Table 310.16 (renumbered from Table 310.15(B)(16) in the 2020 NEC) gives 12 AWG copper 20 A at 60 degrees C, 25 A at 75 degrees C and 30 A at 90 degrees C. Overcurrent protection for 12 AWG is still limited to 20 A by 240.4(D).
Reference: NFPA 70 National Electrical Code, 2020 edition, Table 310.16
Alarm cables are installed in a hollow space and a vertical shaft of a building. Which general requirement applies to the installation?
Answer: It must not substantially increase the possible spread of fire or products of combustion
Section 300.21 requires electrical installations in hollow spaces, vertical shafts and ventilation or air-handling ducts to be made so that the possible spread of fire or products of combustion will not be substantially increased, and requires penetrations through fire-rated assemblies to be firestopped with approved methods.
Reference: NFPA 70 National Electrical Code, 2020 edition, 300.21
Who may remove a lockout device from an energy-isolating device?
Answer: Only the employee who applied it, with narrow exceptions
29 CFR 1910.147(e)(3) requires each lockout or tagout device to be removed from each energy-isolating device by the employee who applied it, subject to a narrow exception where the employer can verify and follow documented steps if that employee is not available.
Reference: 29 CFR 1910.147, The control of hazardous energy (lockout/tagout), 1910.147(e)(3)
Where must the service disconnecting means be located?
Answer: Readily accessible, outside or nearest the entry point
Section 230.70(A)(1) requires the service disconnecting means at a readily accessible location either outside the building or inside nearest the point of entrance of the service conductors. 230.70(A)(2) prohibits installing it in a bathroom.
Reference: NFPA 70 National Electrical Code, 2020 edition, 230.70(A)(1) and (A)(2)
Sources
- PSI: Hawaii Electricians Candidate Information Bulletin (3/22/2024) (opens in a new tab)
- Hawaii DCCA Professional and Vocational Licensing (opens in a new tab)
- Hawaii Revised Statutes chapter 448E (electricians and plumbers) (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.