Hawaii Journey Worker Electrician Exam: Practice Test & Licensing Guide

The PSI exam for Hawaii's journey worker electrician license: 70 questions on the 2020 NEC covering services, grounding, conductors, raceways, special occupancies and safety. Open book with the NEC provided.

Questions
70
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Electrical Knowledge

A new 480Y/277-volt panelboard has exposed live parts behind its dead front. A grounded concrete wall faces the panelboard across the working space, and nothing energized is on the opposite side. What is the minimum depth of working space required in front of the panelboard?

Requirements at a glance

AgencyHawaii Board of Electricians and Plumbers (DCCA PVL); exams by PSI
ExperienceAge 18 or older, 5 years (at least 10,000 hours) of residential or commercial wiring under a journey worker or supervising electrician, and 240 hours of electrical coursework accepted by a University of Hawaii community college (HRS 448E-5(b))
ExamJourney worker electrician: 70 questions, 3 hours, 70%
Books allowedNone; the 2020 NEC is provided in the exam center
Fee$95 to PSI, plus the Board's application and license fees

Electricians applying for a Hawaii journey worker electrician license from the Board of Electricians and Plumbers.

How to get licensed, step by step

  1. Apply to the Board

    Send the Board of Electricians and Plumbers your application with proof of your experience. You can't register with PSI until it approves you.

    Board of Electricians and Plumbers (opens in a new tab)Hawaii Revised Statutes chapter 448E (electricians and plumbers) (opens in a new tab)Hawaii Administrative Rules 16-80 (electricians and plumbers) (opens in a new tab)

  2. Schedule the journey worker electrician exam with PSI

    Register online or call PSI at 833-333-4754. Your approval is good for 2 years and you can test as often as you like in that time.

    Schedule with PSI (Hawaii trade exams) (opens in a new tab)

  3. Get licensed

    PSI reports your result to the Board; follow the Board's instructions for the license fee and any remaining requirements.

    Board of Electricians and Plumbers (opens in a new tab)

How to prepare

  • Hawaii's trade exams are PSI exams on specific editions: the 2020 NEC, the 2018 UPC, IMC, IFGC and IBC. Hawaii's state electrical code is older than the 2020 NEC, so study to the editions on PSI's bulletin, and check the bulletin again before test day.
  • Contractor exams are closed book except C-13, where PSI provides the NEC. Electrician exams provide the NEC too. Plumber and other contractor exams allow no reference books.
  • Service, feeders and branch circuits, grounding and bonding, and conductors and cables (10 each) are 30 of the 70 questions: know where Articles 210, 215, 220, 230, 250 and 310 live.
  • The NEC is provided, so practice finding answers fast in the 2020 edition rather than memorizing.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2020 National Electrical Code (NEC), NFPA 70Essential

    Provided in the exam center, so you can't bring your own. Practice finding answers fast.

    NFPA store (opens in a new tab)

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code, 2020 edition (provided in the exam center)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Electrical Knowledge10
Service, Feeders, and Branch Circuits10
Grounding and Bonding10
Conductors and Cables10
Raceways and Boxes6
Special Occupancies, Conditions, and Equipment6
Electrical Power, Motors, and Equipment for General Use6
Low Voltage and Communication Circuits4
Lighting4
Safety Information4

Exam day details

  • Administered by PSI Services for the Hawaii Board of Electricians and Plumbers.
  • Fee: $95 to PSI. Board application and license fees are separate.
  • 70 scored questions in 3 hours; 49 correct (70%) to pass.
  • The Board must approve your application before you can register with PSI. Your eligibility lasts 2 years, and you can test as often as you like within it.
  • PSI may add up to 10 unscored pretest questions; they do not count against your time.
  • PSI provides an online calculator, or you can bring a silent, non-programmable one.

Frequently asked questions

What's on the Hawaii journey worker electrician exam?

70 scored questions: general electrical knowledge 10, service, feeders and branch circuits 10, grounding and bonding 10, conductors and cables 10, raceways and boxes 6, special occupancies 6, electrical power, motors and equipment 6, low voltage and communication 4, lighting 4 and safety 4.

Which NEC edition is on the Hawaii electrician exams?

The 2020 NEC, per PSI's bulletin. The exam center provides a copy; you may not bring your own, and the NESR, NFPA 72 and Ugly's are not allowed.

Is the exam open book?

Yes. PSI provides the 2020 NEC in the exam center.

Free questions with answers

Show all 10 free questions and answers
  1. A new 480Y/277-volt panelboard has exposed live parts behind its dead front. A grounded concrete wall faces the panelboard across the working space, and nothing energized is on the opposite side. What is the minimum depth of working space required in front of the panelboard?

    Answer: 3 ft 6 in

    Table 110.26(A)(1) lists 151 to 600 volts to ground. Condition 1 (nothing live opposite) is 3 ft, Condition 2 (live parts on one side, grounded parts on the other, such as a concrete wall) is 3 ft 6 in, and Condition 3 (live parts on both sides) is 4 ft. Concrete walls are treated as grounded, so Condition 2 applies.

    Reference: 2020 National Electrical Code (NFPA 70), Table 110.26(A)(1)

  2. In the living room of a new dwelling, receptacle outlets must be placed so that no point measured horizontally along the floor line of any usable wall space is farther than what distance from an outlet?

    Answer: 6 feet

    210.52(A)(1) requires receptacles so that no point along the floor line of wall space is more than 6 ft from an outlet, which means outlets no more than 12 ft apart along a continuous wall. The 12 ft value is the spacing between outlets, not the distance to the nearest one.

    Reference: 2020 National Electrical Code (NFPA 70), 210.52(A)(1)

  3. A service uses 4/0 AWG copper service-entrance conductors, and the grounding electrode conductor connects to a metal water pipe electrode and the building steel. Using Table 250.66, what is the minimum size copper grounding electrode conductor?

    Answer: 2 AWG copper

    In Table 250.66 the row for copper service conductors over 3/0 AWG through 350 kcmil calls for a 2 AWG copper grounding electrode conductor. 4/0 AWG falls in that row. 4 AWG is the row for 2/0 and 3/0, and 1/0 is for conductors over 350 through 600 kcmil.

    Reference: 2020 National Electrical Code (NFPA 70), Table 250.66

  4. A 4 AWG copper THHN conductor (95 A in the 90 C column of Table 310.16) is in a conduit with six current-carrying conductors in a 40 C ambient. What is the adjusted ampacity?

    Answer: 69.2 amperes

    Apply both corrections to the 90 C value: the 36 to 40 C ambient factor for 90 C insulation is 0.91 (Table 310.15(B)(1)), and four through six current-carrying conductors need 0.80 under Table 310.15(C)(1). 95 x 0.91 x 0.80 = 69.2 A. Using only the 0.80 factor gives 76 A, only the ambient factor gives 86.5 A, and the 70 percent factor (7 to 9 conductors) gives 60.5 A.

    Reference: 2020 National Electrical Code (NFPA 70), Table 310.15(B)(1); Table 310.15(C)(1)

  5. A 3/4-inch EMT has an internal area of 0.533 square inches, so 40 percent fill is 0.213 square inches. How many 10 AWG THHN conductors (0.0211 square inches each, Chapter 9, Table 5) may be installed?

    Answer: 10

    For more than two conductors the 40 percent fill column applies: 0.213 / 0.0211 = 10.09, so 10 whole conductors fit (the Chapter 9 Note on rounding up applies only when the result is 0.8 or more above a whole number, and 0.09 is not). The value 25 comes from dividing the total internal area by 0.0211 without the fill limit.

    Reference: 2020 National Electrical Code (NFPA 70), Chapter 9, Table 1, Table 4 (EMT), Table 5

  6. After the normal supply to a building fails, emergency lighting and power for an emergency system must be available within what maximum time?

    Answer: 10 seconds

    700.12 requires an emergency system to supply emergency lighting, power or both within the time required for the application but not more than 10 seconds. The 60 second period is the allowance for legally required standby systems (701.12).

    Reference: 2020 National Electrical Code (NFPA 70), 700.12

  7. A 25-hp, 460-volt, three-phase induction motor is installed on a branch circuit. Using Table 430.250 (34 A full-load current), what is the minimum ampacity of the branch-circuit conductors for this single continuous-duty motor?

    Answer: 42.5 amperes

    430.22(A) requires branch-circuit conductors for a single motor to have an ampacity of at least 125 percent of the motor's full-load current from the table. 34 A x 1.25 = 42.5 A. Using the table value alone gives 34 A, 115 percent (the disconnect rule) gives 39.1 A, and 175 percent (a time-delay fuse multiplier) gives 59.5 A.

    Reference: 2020 National Electrical Code (NFPA 70), 430.22(A); Table 430.250

  8. What is the smallest size of conductor permitted for the bonding conductor or grounding electrode conductor of a communications primary protector?

    Answer: 14 AWG

    800.100(A)(3) states that the bonding conductor or grounding electrode conductor for a communications system shall not be smaller than 14 AWG, and need not exceed 6 AWG. It must also have current-carrying capacity at least equal to that of the protected cable's metal members.

    Reference: 2020 National Electrical Code (NFPA 70), 800.100(A)(3)

  9. A pendant luminaire is proposed above a bathtub in a new bathroom. Which statement matches the Code?

    Answer: No part of a hanging luminaire may be within 3 ft horizontally and 8 ft vertically of the tub rim

    410.10(D) prohibits cord-connected, chain-, cable- or cord-suspended luminaires, track lighting, pendants and ceiling-suspended fans from the zone 3 ft horizontally and 8 ft vertically from the top of the bathtub rim or shower threshold. GFCI protection or a damp location listing does not change the zone.

    Reference: 2020 National Electrical Code (NFPA 70), 410.10(D)

  10. Before working on a circuit, under OSHA's rule for live parts, what should normally be done first?

    Answer: De-energize the parts, unless doing so adds a greater hazard or is infeasible

    29 CFR 1910.333(a)(1) requires live parts to which an employee may be exposed to be de-energized before the employee works on or near them, unless the employer can demonstrate that de-energizing introduces additional or increased hazards or is infeasible because of equipment design or operational limitations. Lighting circuits are not exempt.

    Reference: 29 CFR Part 1910 (OSHA General Industry), 1910.333(a)(1)

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.