Georgia licensing exam

Georgia Residential-Basic Contractor Exam: Practice Test & Licensing Guide

The PSI trade exam for Georgia's Residential-Basic contractor license: 80 questions on sitework, concrete, masonry, carpentry, roofing, code knowledge and OSHA under the 2018 IRC. Open book, 70% to pass.

Questions
80
Time limit
3.3333333333333335 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Sitework, Footings and Foundation

Under Section R403.1.1 of the 2018 IRC, what is the maximum projection allowed beyond the wall face for a concrete footing 8 inches thick?

Requirements at a glance

AgencyGeorgia State Licensing Board for Residential and General Contractors; exams by PSI
ExamResidential-Basic exam (80 questions, 200 minutes, open book, 70% (56) to pass) plus the Business and Law exam
Books allowed2018 IRC, 29 CFR 1926, Carpentry and Building Construction, BCSI truss guide, ACI concrete guide, Modern Masonry and the other references on the PSI list
Fees$72 (Residential-Basic or Residential-Light Commercial), $106 (General Contractor) or $60 (Business and Law) to PSI per the PSI bulletin, plus the Board's application and license fees

Individuals and qualifying agents applying for a Georgia Residential-Basic contractor license from the State Licensing Board for Residential and General Contractors, in addition to the Business and Law exam.

How to get licensed, step by step

  1. Apply to the Board

    Get approved by the Residential and General Contractors board first, then register with PSI. You need both the Business and Law exam and the trade exam.

    Georgia State Licensing Board for Residential and General Contractors (opens in a new tab)

  2. Mind the attempt limits

    You get 2 attempts per exam approval within the 1-year eligibility period. After two failures of the same exam you must wait at least 1 year (O.C.G.A. 43-41-6(g)).

    PSI bulletin: Georgia residential and general contractors (opens in a new tab)

How to prepare

  • General code and construction knowledge (18) and carpentry (16) are 34 of the 80 questions: tab the 2018 IRC chapters on foundations, framing and roofing.
  • Code questions use only the 2018 IRC; other references may be later editions.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2018 International Residential Code (IRC)Essential

    Allowed in the Residential-Basic exam room. Code questions are based only on the 2018 edition.

    ICC store (opens in a new tab)

Official reference list (as published by the testing agency)
  • International Residential Code, 2018 (ICC)
  • 29 CFR Part 1926 (OSHA construction standards)
  • Carpentry and Building Construction, 2010 or 2016 (Feirer and Feirer)
  • BCSI: Guide to Good Practice for Handling, Installing, Restraining, and Bracing of Metal Plate Connected Wood Trusses (2018)
  • The Contractor's Guide to Quality Concrete Construction, 3rd Edition (ACI)
  • Modern Masonry, 8th Edition (Kicklighter) and the other references on the PSI list

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Sitework, Footings and Foundation8
Concrete and Concrete Reinforcement8
Masonry5
Carpentry16
Roofing8
General Code and Construction Knowledge18
Associated Trades10
OSHA Safety7

Exam day details

  • Administered by PSI Services for the Georgia State Licensing Board for Residential and General Contractors.
  • Fee: $72 to PSI per the PSI bulletin. The Board's application and license fees are separate.
  • 80 scored questions in 200 minutes; 56 correct (70%) to pass.
  • Open book. Code questions are based only on the 2018 IRC edition on the PSI list. References may be highlighted, underlined and indexed with permanent tabs, but not written in.
  • Residential-Basic licensing also requires the Georgia Business and Law exam, which you pass once for all residential and general contractor licenses.
  • Under the PSI bulletin you get 2 attempts per exam approval within the 1-year eligibility period; after two failures of the same exam you must wait at least 1 year (O.C.G.A. 43-41-6(g)).

Frequently asked questions

What's on the Georgia Residential-Basic exam?

80 questions: general code and construction knowledge 18, carpentry 16, associated trades 10, sitework, footings and foundation 8, concrete 8, roofing 8, OSHA safety 7 and masonry 5.

Is this the same board as the electrical and plumbing licenses?

No. Residential and general contractors are licensed by a separate board. Electrical, plumbing, conditioned air and low voltage are licensed by the Construction Industry Licensing Board.

Which exams do I need for a Residential-Basic license?

The Residential-Basic exam and the Georgia Business and Law exam.

Free questions with answers

Show all 10 free questions and answers
  1. Under Section R403.1.1 of the 2018 IRC, what is the maximum projection allowed beyond the wall face for a concrete footing 8 inches thick?

    Answer: 8 inches

    R403.1.1 says footing projections must be at least 2 inches and may not exceed the thickness of the footing. An 8-inch-thick footing therefore may not project more than 8 inches beyond the face of the wall it carries.

    Reference: 2018 International Residential Code, Section R403.1.1

  2. A garage floor slab and front porch in a region with severe weathering potential are exposed to deicing salts. According to Table R402.2, what minimum f'c applies?

    Answer: 3,500 psi, air entrained as the table footnotes require

    Table R402.2 sets 3,500 psi for porches, carport slabs, steps exposed to the weather and garage floor slabs where weathering potential is severe (3,000 psi moderate, 2,500 negligible). Footnote d requires air entrainment of 5 to 7 percent. The 4,000 psi figure applies only under footnote f, as the trade-off for reducing air to 3 percent in a steel-troweled garage floor.

    Reference: 2018 International Residential Code, Section R402.2 and Table R402.2

  3. About how many standard 8x8x16 nominal concrete blocks are needed for a straight wall 40 feet long and 8 feet high, before any waste allowance? (Nominal face 16 x 8 inches.)

    Answer: 360 blocks

    One block face is 16 x 8 = 128 sq in = 0.889 sq ft, so about 1.125 blocks cover each square foot. Wall area = 40 x 8 = 320 sq ft. 320 x 1.125 = 360 blocks. Using 1 block per square foot gives 320; 405 applies the 1.125 factor twice; 40 is just the wall length.

    Reference: General trade practice, Masonry quantity takeoff (1.125 blocks per square foot of wall, nominal 8x16 face)

  4. What minimum bearing must the end of a floor joist have on a wood or metal support (without hangers) under the 2018 IRC?

    Answer: 1-1/2 inches

    R502.6 requires 1-1/2 inches of bearing on wood or metal and 3 inches on masonry or concrete, unless the joist is carried by approved hangers or a ribbon strip. Three inches is the masonry figure.

    Reference: 2018 International Residential Code, Section R502.6

  5. Floor joists from opposite sides of a girder lap over the support. What lap and nailing does R502.6.1 require?

    Answer: At least 3 inches of lap with a minimum of three 10d face nails

    R502.6.1 requires joists framing from opposite sides over a bearing support to lap not less than 3 inches and be nailed together with at least three 10d face nails; a splice of equal strength is an allowed alternative.

    Reference: 2018 International Residential Code, Section R502.6.1

  6. What is the lowest roof slope on which asphalt shingles may be installed under the 2018 IRC?

    Answer: 2 units vertical in 12 horizontal

    R905.2.2 allows asphalt shingles only on slopes of 2:12 (17 percent) or greater. Between 2:12 and 4:12, double underlayment is required.

    Reference: 2018 International Residential Code, Section R905.2.2

  7. A bedroom measures 12 feet by 14 feet. What minimum aggregate glazing area and minimum openable area must it have under R303.1?

    Answer: 13.4 square feet of glazing and 6.7 square feet openable

    Floor area = 12 x 14 = 168 sq ft. Glazing must be 8 percent: 168 x 0.08 = 13.44 sq ft. Natural ventilation must be 4 percent: 168 x 0.04 = 6.72 sq ft. Reversing the two percentages is the common error.

    Reference: 2018 International Residential Code, Section R303.1

  8. What is the minimum net clear opening area of an emergency escape and rescue window on an upper floor?

    Answer: 5.7 square feet

    R310.2.1 requires a net clear opening of at least 5.7 square feet, at least 24 inches high and at least 20 inches wide. Grade-floor and below-grade openings may be 5 square feet.

    Reference: 2018 International Residential Code, Section R310.2.1

  9. A framing crew is working on a scaffold platform. Above what height above a lower level must each employee on a scaffold be protected from falling?

    Answer: More than 10 feet

    1926.451(g)(1) requires fall protection for each employee on a scaffold more than 10 feet above a lower level. General construction fall protection under 1926.501 starts at 6 feet, which is a different trigger.

    Reference: 29 CFR Part 1926 (OSHA Construction Standards), 29 CFR 1926.451(g)(1)

  10. What is the maximum setting of a pressure relief valve on a residential water heater under the 2018 IRC?

    Answer: 150 psi

    Section P2804.3 requires the pressure relief valve to be set to open at least 25 psi above the system pressure but not over 150 psi, and the setting may not exceed the tank rated working pressure. The temperature setting (210 degrees F) is a separate limit in P2804.4.

    Reference: 2018 International Residential Code, Section P2804.3

Sources

Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.