Connecticut licensing exam

Connecticut D-2 Limited Warm Air, Air Conditioning and Refrigeration System Journeyperson Exam: Practice Test & Licensing Guide

The PSI trade exam for Connecticut's D-2 limited warm air, air conditioning and refrigeration system journeyperson license: 60 questions covering mechanical code, fuel gas and heating, cooling or burner work. Open book.

Questions
60
Time limit
2 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Fuel Gas Systems

A new natural gas piping system in a commercial kitchen will operate at a maximum working pressure of 8 psig. What is the minimum pressure for the strength and leak test under NFPA 54 8.1.4.2?

Requirements at a glance

AgencyConnecticut Department of Consumer Protection (DCP); exams by PSI
ExperienceA completed bona fide apprenticeship in the specific area of the trade; the experience required for a limited license may be less than 4 years (CGS 20-334a(a)(2)); age 18
ExamsD-2 warm air, A/C and refrigeration exam: 60 questions, 2 hours, 70%
Books allowedIMC (2015, 2018 and 2021), NFPA 54 (2012), NFPA 58, Modern Refrigeration and Air Conditioning 22nd edition, SMACNA duct standards and 29 CFR 1926
Fees$59 at PSI; DCP $90 application fee (CGS 20-333) and $120 initial license fee (CGS 20-335); renews yearly for $120

Workers with a registered apprenticeship and experience in the trade (or equivalent DCP accepts) applying for a Connecticut D-2 license from the Department of Consumer Protection.

How to get licensed, step by step

  1. Confirm you qualify

    Journeyperson licenses need a completed registered apprenticeship with at least 4 years of experience (or equivalent experience and training DCP accepts), then the trade exam only.

    Connecticut DCP: trade license examinations (opens in a new tab)Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)

  2. Apply to DCP

    DCP decides whether you are eligible to test. Once approved, you contact PSI to pay and schedule.

    Connecticut DCP: trade license examinations (opens in a new tab)

  3. Pass the trade exam with PSI

    Both are open book at $59 each. You can test as often as needed for up to one year from your eligibility date. A passing Business and Law score counts for 2 years toward another contractor license.

    Schedule with PSI (Connecticut occupational licenses) (opens in a new tab)

  4. Get licensed

    Send DCP your passing score report or reports with the license fee shown on it.

    Connecticut DCP: trade license examinations (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's list. You can highlight, underline, annotate and index them with permanent tabs, but you can't write in them during the exam and Post-It notes are not allowed.
  • Connecticut's 2022 State Building Code uses the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments, and points to NFPA 54 and NFPA 58 for fuel gas (the IFGC is not adopted). The bulletin allows several editions, so check it for your test date.
  • Fuel gas systems is 10 of 60 questions; use the longest length method for gas pipe sizing.
  • There is no load calculation section on the D-2. Refrigerants and refrigeration (8) and ducts (6) are the largest trade sections.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the IMC and NFPA 54. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • International Mechanical Code (IMC), 2015, 2018 or 2021 (Connecticut adopts 2021 with amendments)Essential

    Allowed in the exam room. The core of the heating, piping and cooling exams.

    ICC store (opens in a new tab)

  • NFPA 54: National Fuel Gas Code (or Handbook), 2012Essential

    Allowed in the exam room. Connecticut uses NFPA 54 rather than the IFGC. Use the longest length method for pipe sizing.

    NFPA store (opens in a new tab)

  • NFPA 58: Liquefied Petroleum Gas Code, 2014

    Allowed in the exam room. LP-gas storage, piping and appliances.

    NFPA store (opens in a new tab)

  • Modern Refrigeration and Air Conditioning, 22nd Edition (Goodheart-Willcox)

    Refrigeration cycle, troubleshooting, piping and controls.

    Goodheart-Willcox (opens in a new tab)

  • 29 CFR 1926 (OSHA Construction Standards), sections on your reference list

    Trenching, scaffolds, fall protection and ladders. Print just the listed sections.

    Read free (eCFR) (opens in a new tab)

Official reference list (as published by the testing agency)
  • International Mechanical Code or Commentary, 2015, 2018 and 2021 editions (allowed in the exam room)
  • NFPA 54: National Fuel Gas Code or Handbook, 2012; use the longest length method for gas pipe sizing (allowed in the exam room)
  • NFPA 58: Liquefied Petroleum Gas Code, 2014 (allowed in the exam room)
  • Modern Refrigeration and Air Conditioning, 22nd Edition (allowed in the exam room)
  • HVAC Duct Construction Standards, 2005, 3rd Edition, SMACNA, and the ACCA Ductulator (allowed in the exam room)
  • 29 CFR Part 1926 (OSHA), or the PSI selections (allowed in the exam room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Insulation1
Hangers and Supports2
Sound/Vibration/Seismic Control1
Heating and Cooling Principles5
Refrigerants and Refrigeration8
Testing, Adjusting and Balancing1
Controls3
Machine Room1
A/C and Heat Pump Equipment5
Furnaces and Heaters4
Chimneys, Flues and Vents2
Combustion Air2
Fuel Gas Systems10
Ducts6
Chillers2
Ventilation and Exhaust3
Safety4

Exam day details

  • Administered by PSI Services for the Connecticut Department of Consumer Protection.
  • Fee: $59 to PSI per exam portion. DCP license fees are separate.
  • 60 questions in 2 hours; 70% to pass. Open book.
  • The license covers warm air heating, air conditioning and refrigeration work (RCSA 20-332).
  • Connecticut's 2022 State Building Code (effective 10/1/2022) is based on the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments. The PSI bulletin (updated 2/4/2026) still lists the 2020 or 2023 NEC and the 2015, 2018 or 2021 IPC or IMC; check the current bulletin for your test date.
  • There is no load calculation section on the D-2, and the Manual J and Manual N books are not on its list.
  • Open book: bring your own copies of the allowed references. You may highlight, underline, annotate and index them beforehand, but not write in them during the exam. Permanent tabs only; Post-It notes are not allowed.
  • Use a silent, nonprinting, non-programmable calculator. For code questions the exam is based only on the edition of the code book listed in the bulletin.
  • Candidates may test as often as needed for up to one year from the date of eligibility. Contractor exam portions (business and trade) are each valid for 2 years from the date passed.
  • Contractor and dealer licenses need two portions: the Business and Law exam and the trade exam. Journeyperson licenses need only the trade exam.

Frequently asked questions

What's on the Connecticut D-2 exam?

60 questions: fuel gas systems 10, refrigerants and refrigeration 8, ducts 6, then heating and cooling principles and A/C and heat pump equipment (5 each) and smaller sections.

Is the D-2 open book?

Yes. You may bring the allowed references listed on the PSI bulletin, tabbed with permanent tabs, and use a silent, non-programmable calculator.

Do I need the Business and Law exam for the D-2?

No. Journeyperson applicants take only the trade exam.

Free questions with answers

Show all 10 free questions and answers
  1. A new natural gas piping system in a commercial kitchen will operate at a maximum working pressure of 8 psig. What is the minimum pressure for the strength and leak test under NFPA 54 8.1.4.2?

    Answer: 12 psig

    8.1.4.2 sets the test pressure at not less than 1-1/2 times the proposed maximum working pressure, with a floor of 3 psi. 8 x 1.5 = 12 psig. Testing at only the working pressure (8) skips the 1.5 factor, doubling (16) uses the wrong factor, and 3 psi is just the minimum that governs low-pressure systems.

    Reference: NFPA 54 (2012), 8.1.4.2

  2. A round galvanized duct 18 inches in diameter serves a single dwelling unit at 1 inch water gauge static pressure. Using IMC Table 603.4, what is the minimum thickness?

    Answer: 0.024 inch

    Table 603.4 for round galvanized duct at 1-inch water gauge lists 0.024 inch for an 18-inch diameter. 0.016 is the 18-inch value at 1/2-inch water gauge, 0.019 is the 15 to 17 inch row at 1 inch, and 0.034 is the aluminum value.

    Reference: 2021 International Mechanical Code (Connecticut 2022 State Building Code), Table 603.4

  3. What maximum horizontal support spacing does IMC Table 305.4 give for PEX tubing 1-1/4 inches and larger?

    Answer: 4 feet

    Table 305.4 gives 2-2/3 feet (32 inches) for PEX 1 inch and smaller and 4 feet for PEX 1-1/4 inches and larger. 8 feet is the horizontal spacing for copper tubing and steel tubing, and 12 feet is for steel pipe and copper pipe.

    Reference: 2021 International Mechanical Code (Connecticut 2022 State Building Code), Table 305.4

  4. Which medium is acceptable under IMC 1110.3 for the pressure test of field-installed refrigerant piping on a typical HFC split system?

    Answer: Oxygen-free nitrogen

    1110.3 allows oxygen-free nitrogen, helium or argon (carbon dioxide for R-744 and water for R-718). Air, oxygen, combustible gases and mixtures containing them are prohibited as a test medium.

    Reference: 2021 International Mechanical Code (Connecticut 2022 State Building Code), 1110.3

  5. A furnace puts 72,000 Btu/h of heat into 1,500 cfm of supply air. Using Btu/h = 1.08 x cfm x delta T, what is the temperature rise across the furnace?

    Answer: About 44 degrees F

    delta T = Btu/h / (1.08 x cfm) = 72,000 / (1.08 x 1,500) = 72,000 / 1,620 = 44.4, about 44 degrees F. 48 leaves out the 1.08 factor (72,000 / 1,500), 52 multiplies by 1.08 instead of dividing (48 x 1.08), and 67 divides by 1,080 as if the airflow were 1,000 cfm.

    Reference: Workforce LibreTexts, Introduction to Residential HVAC Level 1, Conversions and Formulas in HVAC, Section 7.06 Sensible Heat Formula

  6. A cooling coil condensate line runs 24 feet horizontally to a floor drain. Using the minimum slope in IMC 307.2.1 (1/8 unit vertical in 12 horizontal), what is the minimum total drop over the run?

    Answer: 3 inches

    The slope is 1/8 inch per 12 inches, or 1/8 inch per foot. 24 ft x 1/8 in = 3 inches of drop. 1.5 inches uses 1/16 inch per foot, 2 inches uses 1/12 inch per foot, and 6 inches uses 1/4 inch per foot.

    Reference: 2021 International Mechanical Code (Connecticut 2022 State Building Code), 307.2.1

  7. Where must the manual shutoff valve be installed on a vented wall furnace under IMC 909.5?

    Answer: Ahead of all controls

    909.5 requires a manual shutoff valve ahead of all controls on a vented wall furnace so that fuel can be isolated before reaching any control.

    Reference: 2021 International Mechanical Code (Connecticut 2022 State Building Code), 909.5

  8. A return air riser serves three stories. Under IMC 606.2.3, smoke detectors are required at each story when the return air system the riser serves has a design capacity greater than what?

    Answer: 15,000 cfm

    606.2.3 requires smoke detectors at each story, located upstream of the connection between the riser and any ducts or plenums, where return air risers serve two or more stories and serve any portion of a return air system with a design capacity greater than 15,000 cfm. 2,000 cfm is the separate return-air-system threshold in 606.2.1.

    Reference: 2021 International Mechanical Code (Connecticut 2022 State Building Code), 606.2.3

  9. A 600-square-foot office will be ventilated by natural means only. What minimum openable area to the outdoors does IMC 402.2 require?

    Answer: 24 square feet

    402.2 requires the minimum openable area to the outdoors to be 4 percent of the floor area being ventilated. 600 x 0.04 = 24 square feet. 12 uses 2 percent, 30 uses 5 percent, and 48 uses 8 percent, which is the figure for interior rooms ventilated through an adjoining space (402.3).

    Reference: 2021 International Mechanical Code (Connecticut 2022 State Building Code), 402.2

  10. A non-self-supporting portable ladder is set with its base 4 feet out from the wall below its top support. Under the 1-to-4 rule of 29 CFR 1926.1053(b)(5)(i), what working length of ladder (foot to top support) does this setup match?

    Answer: 16 feet

    1926.1053(b)(5)(i) sets the horizontal distance from the top support to the foot at about one-quarter of the working length. Working length = 4 x 4 = 16 feet. 8 feet uses a 1:2 ratio, 12 feet a 1:3 ratio, and 32 feet uses the 1:8 ratio meant for wood job-made ladders with spliced side rails.

    Reference: 29 CFR 1926 (OSHA Construction Standards), 1926.1053(b)(5)(i)

Sources

Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.