Requirements at a glance
| Agency | Connecticut Department of Consumer Protection (DCP); exams by PSI |
|---|---|
| Experience | A completed bona fide apprenticeship in the specific area of the trade; the experience required for a limited license may be less than 4 years (CGS 20-334a(a)(2)); age 18 |
| Exams | B-2 gas and oil burner exam: 40 questions, 90 minutes, 70% |
| Books allowed | IMC, IRC, IFGC (2015, 2018 and 2021), NFPA 31, NFPA 54 (2012) and NFPA 58 |
| Fees | $59 at PSI; DCP $90 application fee (CGS 20-333) and $120 initial license fee (CGS 20-335); renews yearly for $120 |
Workers with a registered apprenticeship and experience in the trade (or equivalent DCP accepts) applying for a Connecticut B-2 license from the Department of Consumer Protection.
Official links
How to get licensed, step by step
Confirm you qualify
Journeyperson licenses need a completed registered apprenticeship with at least 4 years of experience (or equivalent experience and training DCP accepts), then the trade exam only.
Connecticut DCP: trade license examinations (opens in a new tab)Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)
Apply to DCP
DCP decides whether you are eligible to test. Once approved, you contact PSI to pay and schedule.
Connecticut DCP: trade license examinations (opens in a new tab)
Pass the trade exam with PSI
Both are open book at $59 each. You can test as often as needed for up to one year from your eligibility date. A passing Business and Law score counts for 2 years toward another contractor license.
Schedule with PSI (Connecticut occupational licenses) (opens in a new tab)
Get licensed
Send DCP your passing score report or reports with the license fee shown on it.
Connecticut DCP: trade license examinations (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's list. You can highlight, underline, annotate and index them with permanent tabs, but you can't write in them during the exam and Post-It notes are not allowed.
- Connecticut's 2022 State Building Code uses the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments, and points to NFPA 54 and NFPA 58 for fuel gas (the IFGC is not adopted). The bulletin allows several editions, so check it for your test date.
- Fuel gas systems is 8 of 40 questions and oil burners 6; liquefied petroleum gas and natural gas are 5 each.
- Piping and valves and general knowledge are 4 each.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the IMC and NFPA 54. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Mechanical Code (IMC), 2015, 2018 or 2021 (Connecticut adopts 2021 with amendments)Essential
Allowed in the exam room. The core of the heating, piping and cooling exams.
International Residential Code (IRC), 2015, 2018 or 2021
Allowed in the B-1 and B-2 exam rooms. Fuel gas, chimney and appliance chapters.
International Fuel Gas Code (IFGC), 2015, 2018 or 2021
Allowed in the B-1 and B-2 exam rooms, though Connecticut's State Building Code uses NFPA 54 for fuel gas.
NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2006 or 2011
Allowed in the exam room. Oil burner and tank installation.
NFPA 54: National Fuel Gas Code (or Handbook), 2012Essential
Allowed in the exam room. Connecticut uses NFPA 54 rather than the IFGC. Use the longest length method for pipe sizing.
NFPA 58: Liquefied Petroleum Gas Code, 2014
Allowed in the exam room. LP-gas storage, piping and appliances.
Official reference list (as published by the testing agency)
- International Mechanical Code or Commentary, 2015, 2018 and 2021 editions (allowed in the exam room)
- International Residential Code, 2015, 2018 and 2021 editions (allowed in the exam room)
- International Fuel Gas Code, 2015, 2018 and 2021 editions (allowed in the exam room; Connecticut's State Building Code uses NFPA 54 instead)
- NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2006 or 2011 (allowed in the exam room)
- NFPA 54: National Fuel Gas Code or Handbook, 2012; use the longest length method for gas pipe sizing (allowed in the exam room)
- NFPA 58: Liquefied Petroleum Gas Code, 2014 (allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Chimneys, Flues and Vents | 2 | |
| Controls | 2 | |
| Equipment | 2 | |
| Fuel Gas Systems | 8 | |
| General Knowledge | 4 | |
| Oil Burners | 6 | |
| Piping and Valves | 4 | |
| Testing and Maintenance | 2 | |
| Liquefied Petroleum Gas | 5 | |
| Natural Gas | 5 |
Exam day details
- Administered by PSI Services for the Connecticut Department of Consumer Protection.
- Fee: $59 to PSI per exam portion. DCP license fees are separate.
- 40 questions in 1.5 hours; 70% to pass. Open book.
- The license covers gas or oil burner work (domestic and light commercial, up to 5 gallons per hour) (RCSA 20-332).
- Connecticut's 2022 State Building Code (effective 10/1/2022) is based on the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments. The PSI bulletin (updated 2/4/2026) still lists the 2020 or 2023 NEC and the 2015, 2018 or 2021 IPC or IMC; check the current bulletin for your test date.
- The bulletin lists the IFGC for this exam, but Connecticut's State Building Code points to NFPA 54 for fuel gas, so gas sizing questions use NFPA 54 (longest length method).
- Open book: bring your own copies of the allowed references. You may highlight, underline, annotate and index them beforehand, but not write in them during the exam. Permanent tabs only; Post-It notes are not allowed.
- Use a silent, nonprinting, non-programmable calculator. For code questions the exam is based only on the edition of the code book listed in the bulletin.
- Candidates may test as often as needed for up to one year from the date of eligibility. Contractor exam portions (business and trade) are each valid for 2 years from the date passed.
- Contractor and dealer licenses need two portions: the Business and Law exam and the trade exam. Journeyperson licenses need only the trade exam.
Frequently asked questions
What's on the Connecticut B-2 exam?
40 questions: fuel gas systems 8, oil burners 6, liquefied petroleum gas 5, natural gas 5, then general knowledge and piping and valves (4 each) and smaller sections.
Is the B-2 open book?
Yes. You may bring the allowed references listed on the PSI bulletin, tabbed with permanent tabs, and use a silent, non-programmable calculator.
Do I need the Business and Law exam for the B-2?
No. Journeyperson applicants take only the trade exam.
Free questions with answers
Show all 10 free questions and answers
A furnace (100,000 Btu/h) and a water heater (40,000 Btu/h) sit in a closet. Combustion air comes from outdoors through two permanent openings, each opening directly to the outdoors. What is the minimum free area of EACH opening?
Answer: 35 square inches
Two-permanent-opening method with openings that communicate directly with the outdoors needs 1 square inch per 4,000 Btu/h of total input at each opening. Total input is 140,000 Btu/h, so 140,000 / 4,000 = 35 square inches each. 70 is the horizontal-duct rate (1 in2 per 2,000), 47 is the single-opening rate (1 in2 per 3,000), and 140 is the indoor rate (1 in2 per 1,000).
Reference: 2021 International Residential Code (Connecticut 2022 CSBC), G2407.6.1
Where does the code prohibit gas shutoff valves?
Answer: In concealed locations and in furnace plenums
Shutoff valves are prohibited in concealed locations and furnace plenums. They must also be accessible for operation and protected from damage. Basements, appliance rooms and the meter area are normal places for valves.
Reference: 2021 International Residential Code (Connecticut 2022 CSBC), G2420.1.2
Which medium may be used to pressure-test new gas piping?
Answer: Air, nitrogen, carbon dioxide or another inert gas
The test medium shall be air, nitrogen, carbon dioxide or an inert gas. Oxygen shall never be used. Fuel gas may be used only for leak checks on piping that has already been pressure tested.
Reference: 2021 International Residential Code (Connecticut 2022 CSBC), G2417.2
What is the minimum size of the supply line to an oil burner when copper tubing is used?
Answer: 3/8-inch outside diameter
The minimum supply line is 3/8-inch inside diameter nominal pipe or 3/8-inch outside diameter tubing. The minimum return line is 1/4-inch inside diameter pipe or 5/16-inch outside diameter tubing. Copper tubing must have a 0.035-inch nominal wall (0.032 minimum).
Reference: 2021 International Mechanical Code (Connecticut 2022 CSBC), 1305.1
A propane tank holds 150 gallons of usable fuel (91,500 Btu per gallon). The connected load is 275,000 Btu/h and runs continuously. About how many hours will the fuel last?
Answer: About 50 hours
Total energy = 150 gal x 91,500 Btu/gal = 13,725,000 Btu. Hours = 13,725,000 / 275,000 = 49.9, about 50 hours. 55 hours comes from rounding the heat content up to 100,000 Btu per gallon.
Reference: NFPA 58 Liquefied Petroleum Gas Code (2004 text on file; exam uses 2014), Annex B, Table B.1.2(a) (total heating value per gallon)
A meter test shows 28 seconds per cubic foot on 1,030 Btu per cubic foot gas. A water heater pilot (1,000 Btu/h) was left on. What is the furnace input?
Answer: About 131,400 Btu/h
Measured input = 1,030 x 3,600 / 28 = 132,429 Btu/h. Subtract the 1,000 Btu/h pilot allowance: 131,429 Btu/h. 132,400 forgets the pilot.
Reference: Weil-McLain 90% Gas Furnace Installer's Information Manual, Checking Gas Input Rate (pilot allowances)
A single-wall metal vent connector serves a draft-hood water heater and enters a Type B gas vent that is 20 ft tall. What is the maximum horizontal length of the connector?
Answer: 15 feet
The maximum horizontal length of a single-wall connector is 75 percent of the chimney or vent height: 0.75 x 20 = 15 ft. A Type B double-wall connector may run 100 percent of the height (20 ft).
Reference: 2021 International Residential Code (Connecticut 2022 CSBC), G2427.10.9
Testing a cad cell primary control, a technician places a jumper across the cad cell terminals (simulating flame) and calls for heat. What should happen?
Answer: The burner must not start; the control stays in standby
This safe start check proves the control will not start into a false flame signal. Remove the jumper afterward. The normal cad cell flame detection range with flame is 0 to 1,600 ohms.
Reference: Beckett AF/AFG Burner Manual (6104, 09/2020), Check Safety Features (Safe Start Check)
Boilers must be mounted on floors of what construction unless listed for combustible flooring?
Answer: Noncombustible
Boilers shall be mounted on floors of noncombustible construction unless listed for mounting on combustible flooring. They must also sit on a level base that supports the weight.
Reference: 2021 International Mechanical Code (Connecticut 2022 CSBC), 1004.5
One gallon of No. 2 fuel oil releases about 140,000 Btu. What is the input of an oil burner firing 1.10 gph?
Answer: 154,000 Btu/h
Input = firing rate x heat content = 1.10 gph x 140,000 Btu/gal = 154,000 Btu/h. NFPA 31 uses this same 140,000 Btu per gallon figure when it equates 1 in2 per 5,000 Btu/h with 28 in2 per gph. 140,000 ignores the firing rate, 110,000 uses 100,000 Btu per gallon, and 127,000 divides by the gph instead of multiplying.
Reference: NFPA 31 Standard for the Installation of Oil-Burning Equipment (2001 text on file; exam allows 2006 or 2011), 5.3.2
Sources
- PSI: Connecticut Heating, Piping and Cooling Examinations Candidate Information Bulletin (updated 2/4/2026) (opens in a new tab)
- Connecticut Department of Consumer Protection: trade license examinations (opens in a new tab)
- Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)
- Connecticut DAS: State Building Code regulations (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.