Requirements at a glance
| Agency | Connecticut Department of Consumer Protection (DCP); exams by PSI |
|---|---|
| Experience | At least 2 years as a licensed journeyperson in the specific area of the trade, or equivalent experience and training DCP accepts (CGS 20-334a(a)(1)); age 18 |
| Exams | B-1 gas and oil burner exam: 50 questions, 2 hours, 70%, plus the Business and Law exam |
| Books allowed | IMC, IRC, IFGC (2015, 2018 and 2021), NFPA 31, NFPA 54 (2012) and NFPA 58 |
| Fees | $59 per PSI exam portion; DCP $150 application fee (CGS 20-333) and $150 initial license fee (CGS 20-335); renews yearly for $150 |
Contractors with at least 2 years as a licensed journeyperson (or experience DCP accepts) applying for a Connecticut B-1 license from the Department of Consumer Protection.
Official links
How to get licensed, step by step
Confirm you qualify
Contractor licenses need at least 2 years as a licensed journeyperson (or equivalent experience and training DCP accepts), plus both the Business and Law exam and the trade exam.
Connecticut DCP: trade license examinations (opens in a new tab)Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)
Apply to DCP
DCP decides whether you are eligible to test. Once approved, you contact PSI to pay and schedule.
Connecticut DCP: trade license examinations (opens in a new tab)
Pass both exam portions with PSI
Both are open book at $59 each. You can test as often as needed for up to one year from your eligibility date. A passing Business and Law score counts for 2 years toward another contractor license.
Schedule with PSI (Connecticut occupational licenses) (opens in a new tab)
Get licensed
Send DCP your passing score report or reports with the license fee shown on it.
Connecticut DCP: trade license examinations (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's list. You can highlight, underline, annotate and index them with permanent tabs, but you can't write in them during the exam and Post-It notes are not allowed.
- Connecticut's 2022 State Building Code uses the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments, and points to NFPA 54 and NFPA 58 for fuel gas (the IFGC is not adopted). The bulletin allows several editions, so check it for your test date.
- Fuel gas systems is 10 of 50 questions, oil burners 7 and general knowledge 6; liquefied petroleum gas and natural gas are 5 each.
- The bulletin lists the IFGC, but Connecticut's code points to NFPA 54 for fuel gas, so use NFPA 54 and the longest length method for sizing.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the IMC and NFPA 54. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Mechanical Code (IMC), 2015, 2018 or 2021 (Connecticut adopts 2021 with amendments)Essential
Allowed in the exam room. The core of the heating, piping and cooling exams.
International Residential Code (IRC), 2015, 2018 or 2021
Allowed in the B-1 and B-2 exam rooms. Fuel gas, chimney and appliance chapters.
International Fuel Gas Code (IFGC), 2015, 2018 or 2021
Allowed in the B-1 and B-2 exam rooms, though Connecticut's State Building Code uses NFPA 54 for fuel gas.
NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2006 or 2011
Allowed in the exam room. Oil burner and tank installation.
NFPA 54: National Fuel Gas Code (or Handbook), 2012Essential
Allowed in the exam room. Connecticut uses NFPA 54 rather than the IFGC. Use the longest length method for pipe sizing.
NFPA 58: Liquefied Petroleum Gas Code, 2014
Allowed in the exam room. LP-gas storage, piping and appliances.
Official reference list (as published by the testing agency)
- International Mechanical Code or Commentary, 2015, 2018 and 2021 editions (allowed in the exam room)
- International Residential Code, 2015, 2018 and 2021 editions (allowed in the exam room)
- International Fuel Gas Code, 2015, 2018 and 2021 editions (allowed in the exam room; Connecticut's State Building Code uses NFPA 54 instead)
- NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2006 or 2011 (allowed in the exam room)
- NFPA 54: National Fuel Gas Code or Handbook, 2012; use the longest length method for gas pipe sizing (allowed in the exam room)
- NFPA 58: Liquefied Petroleum Gas Code, 2014 (allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Chimneys, Flues and Vents | 2 | |
| Controls | 4 | |
| Equipment | 4 | |
| Fuel Gas Systems | 10 | |
| General Knowledge | 6 | |
| Oil Burners | 7 | |
| Piping and Valves | 4 | |
| Testing and Maintenance | 3 | |
| Liquefied Petroleum Gas | 5 | |
| Natural Gas | 5 |
Exam day details
- Administered by PSI Services for the Connecticut Department of Consumer Protection.
- Fee: $59 to PSI per exam portion. DCP license fees are separate.
- 50 questions in 2 hours; 70% to pass. Open book.
- The license covers gas or oil burner work (domestic and light commercial, up to 5 gallons per hour) (RCSA 20-332).
- Connecticut's 2022 State Building Code (effective 10/1/2022) is based on the 2021 IPC and IMC and the 2020 NEC, each with Connecticut amendments. The PSI bulletin (updated 2/4/2026) still lists the 2020 or 2023 NEC and the 2015, 2018 or 2021 IPC or IMC; check the current bulletin for your test date.
- The bulletin lists the IFGC for this exam, but Connecticut's State Building Code points to NFPA 54 for fuel gas, so gas sizing questions use NFPA 54 (longest length method).
- Open book: bring your own copies of the allowed references. You may highlight, underline, annotate and index them beforehand, but not write in them during the exam. Permanent tabs only; Post-It notes are not allowed.
- Use a silent, nonprinting, non-programmable calculator. For code questions the exam is based only on the edition of the code book listed in the bulletin.
- Candidates may test as often as needed for up to one year from the date of eligibility. Contractor exam portions (business and trade) are each valid for 2 years from the date passed.
- Contractor and dealer licenses need two portions: the Business and Law exam and the trade exam. Journeyperson licenses need only the trade exam.
Frequently asked questions
What's on the Connecticut B-1 exam?
50 questions: fuel gas systems 10, oil burners 7, general knowledge 6, liquefied petroleum gas 5, natural gas 5, then controls, equipment and piping and valves (4 each) and smaller sections.
Is the B-1 open book?
Yes. You may bring the allowed references listed on the PSI bulletin, tabbed with permanent tabs, and use a silent, non-programmable calculator.
Do I also need the Business and Law exam?
Yes. Contractor licenses need both the Business and Law exam and the B-1 trade exam.
Free questions with answers
Show all 10 free questions and answers
A natural gas system will operate at 7 in. w.c. (about 0.25 psig). What test pressure must be used under the code?
Answer: 3 psig, because 1-1/2 times 0.25 psig is below the code minimum
G2417.4.1: test at not less than 1-1/2 times the working pressure but not less than 3 psig 'irrespective of design pressure'. 1.5 x 0.25 = 0.375 psig, which is below the floor, so 3 psig governs.
Reference: 2021 International Residential Code, Chapter 24 (Connecticut State Building Code), G2417.4.1
A two-pipe oil burner system is being piped with steel pipe. Under IMC 1305.1, what are the minimum nominal inside diameters for the supply line and the return line?
Answer: Supply 3/8 inch and return 1/4 inch
IMC 1305.1 sets the minimum supply line at 3/8-inch inside diameter nominal pipe (or 3/8-inch OD tubing) and the minimum return line at 1/4-inch inside diameter nominal pipe (or 5/16-inch OD tubing). The return may be smaller because it carries only the excess oil bypassed by the fuel unit.
Reference: 2021 International Mechanical Code (Connecticut), 1305.1
A new oil burner supply line has a maximum working pressure of 4 psig. What is the minimum pressure for the leak test of the piping under NFPA 31, measured at the highest point of the system?
Answer: 6 psig, because 1-1/2 times 4 psig is above the 5 psig floor
NFPA 31 (2001 text, 8.8.1) requires piping to be tested hydrostatically or with air at not less than 1-1/2 times the maximum working pressure but not less than 5 psig at the highest point. 1.5 x 4 = 6 psig, which is above the 5 psig floor, so 6 psig is used. 8.8.1.1 also says the test must not put more than 10 psig on any connected tank.
Reference: NFPA 31 (2001 text on file; exam allows 2006 or 2011), 8.8.1, 8.8.1.1
Under G2414.4.3, copper tubing may not be used for gas that contains more than an average of how much hydrogen sulfide?
Answer: 0.3 grains per 100 standard cubic feet of gas
G2414.4.3 allows Type K or L copper tubing (ASTM B88 or B280) only if the gas contains no more than an average of 0.3 grains of hydrogen sulfide per 100 standard cubic feet. Higher sulfur content corrodes copper and copper alloys.
Reference: 2021 International Residential Code, Chapter 24 (Connecticut State Building Code), G2414.4.3
What minimum pitch must an oil appliance chimney connector maintain from the appliance to the chimney under NFPA 31?
Answer: 1/4 inch per foot of horizontal run, rising toward the chimney
NFPA 31 6.5.8 requires the chimney connector to maintain a pitch or rise of at least 1/4 inch per foot of horizontal pipe from the appliance to the chimney so flue gases keep moving upward. Connectors may not be smaller than the appliance flue collar (6.5.6).
Reference: NFPA 31 (2001 text on file; exam allows 2006 or 2011), 6.5.8
Which boilers must be protected with a low-water cutoff control under IMC 1007.1?
Answer: Steam and hot water boilers, except coil-type and water-tube boilers protected by a flow-sensing control
IMC 1007.1 requires a low-water cutoff on steam and hot water boilers. The exception is for coil-type and water-tube boilers that need forced circulation of water through the boiler and are protected by a flow-sensing control. Size or input rating does not change the rule.
Reference: 2021 International Mechanical Code (Connecticut), 1007.1
Which statement about boiler relief valve discharge piping is correct under IMC 1006.6?
Answer: It may not terminate more than 6 inches above the floor or waste receptor and may not end in a threaded connection
IMC 1006.6: discharge piping is rigid pipe approved for the system temperature, must discharge through an air break (not directly connected to drainage), is not smaller than the valve outlet, serves a single device, is not trapped, has no valves or tees, does not terminate more than 6 inches above the floor or receptor and has no threaded end connection.
Reference: 2021 International Mechanical Code (Connecticut), 1006.6
An oil burner is nozzled at 3.5 gal/h. Using the 140,000 Btu/h per gal/h conversion given in NFPA 31's combustion air rules, what is the burner input?
Answer: 490,000 Btu/h
NFPA 31 5.4.1 pairs 1 in.2 per 1,000 Btu/h with 140 in.2 per gal/h, which means 1 gal/h is 140,000 Btu/h. 3.5 x 140,000 = 490,000 Btu/h. The 350,000 figure uses 100,000 Btu per gallon; 49,000 is a decimal slip.
Reference: NFPA 31 (2001 text on file; exam allows 2006 or 2011), 5.4.1 (140 in.2 per gal/hr = 1 in.2 per 1,000 Btu/hr)
NFPA 58 requires LP-gas to be odorized so it is detectable by a distinct odor at not over one-fifth of the lower limit of flammability. The lower limit for propane is 2.15 percent gas in air. At what concentration must the odor be detectable?
Answer: About 0.43 percent gas in air
One-fifth of the lower limit of flammability: 2.15 / 5 = 0.43 percent gas in air. 2.15 is the lower flammable limit itself, 9.60 is the upper limit, and 10.75 is 2.15 x 5, which multiplies instead of dividing.
Reference: NFPA 58 (2004 text on file; exam lists 2014), 4.2.1; Annex B, Table B.1.2(a)
A natural gas system has an inlet pressure of 2.0 psi and a 1.0 psi design drop. The longest run is 40 feet and the load is 2,000 cubic feet per hour. Using Table G2413.4(2) and the longest length method, what is the smallest schedule 40 pipe?
Answer: 1 inch
Longest length method (G2413.4.1): use the 40 ft row of Table G2413.4(2) (2.0 psi inlet, 1.0 psi drop): 1/2 in. = 753, 3/4 in. = 1,520, 1 in. = 2,780 cfh. 1,520 is less than 2,000, so 3/4 in. is too small; 1 in. is the smallest that carries 2,000 cfh.
Reference: 2021 International Residential Code, Chapter 24 (Connecticut State Building Code), G2413.4.1, Table G2413.4(2)
Sources
- PSI: Connecticut Heating, Piping and Cooling Examinations Candidate Information Bulletin (updated 2/4/2026) (opens in a new tab)
- Connecticut Department of Consumer Protection: trade license examinations (opens in a new tab)
- Connecticut General Statutes Chapter 393 (trade licensing) (opens in a new tab)
- Connecticut DAS: State Building Code regulations (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.