Requirements at a glance
| Agency | California DIR, Division of Labor Standards Enforcement: Electrician Certification Unit (ECU) |
|---|---|
| Who | Electricians working on single-family and multifamily buildings with a utility supply of at most 3-phase 4-wire 120/208 V or 120/240 V, for a C-10 or C-7 electrical contractor |
| Format | 80 questions, 3 hours 30 minutes, 70% to pass; NEC 2023, NFPA 70E 2024 and the Cal/OSHA Pocket Guide are on screen |
| Retest | Wait 60 days after a failed attempt; $100 retest fee |
Electricians who install, construct or maintain electrical systems in single-family and multifamily residential buildings where the utility supply is at most 3-phase 4-wire 120/208 V or 120/240 V, working for a C-10 or C-7 electrical contractor in California (Labor Code 108).
Official links
How to get licensed, step by step
Apply to the ECU
Send the Residential Electrician application and supporting documents to DLSE's Electrician Certification Unit and wait for approval.
DIR/DLSE: Electrician Certification Unit test information (opens in a new tab)
Schedule with Pearson VUE
After approval you schedule the exam through Pearson VUE. Exams on or after June 1, 2026 are administered by CPS HR Consulting.
Pearson VUE: ECU Candidate Information Bulletin (PDF) (opens in a new tab)
Take the exam
The NEC 2023, NFPA 70E 2024 and the Cal/OSHA Pocket Guide are searchable on screen. Your certification card is mailed after you pass.
How to prepare
- Installation is 66% of the exam, so spend most of your time on NEC Chapters 2 to 4 with a residential focus: branch circuits, services, GFCI and AFCI, and grounding.
- Determination of electrical system requirements (23%) is load calculation and sizing; practice dwelling-unit calculations.
- You can't bring books, so practice finding rules in a searchable NEC quickly.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the on-screen NEC 2023. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NEC 2023, NFPA 70E 2024 and Cal/OSHA Pocket Guide (on screen)Essential
Provided on the exam screen. Practice finding articles and tables fast; you can't bring your own copies.
Pearson VUE: ECU Candidate Information Bulletin (PDF) (opens in a new tab)
Official reference list (as published by the testing agency)
- National Electrical Code (NEC) 2023, provided on screen during the exam
- NFPA 70E 2024, provided on screen during the exam
- Cal/OSHA Electrical Safety Orders Pocket Guide, 2022, provided on screen during the exam
What's on the exam
Official content outline from CPS HR Consulting (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Safety | 5 | |
| Determination of Electrical System Requirements | 23 | |
| Installation | 66 | |
| Maintenance and Repair | 6 |
The outline totals 100; the other items on the 80-question exam are unscored or unassigned.
Exam day details
- Administered by CPS HR Consulting for the DIR Division of Labor Standards Enforcement (DLSE), at Pearson VUE test centers.
- Fee: $75 application fee paid to DLSE, plus $100 to take the exam (the same $100 for each retake, which can't be taken until 60 days after a failed attempt). Certification renewal is $100.
- 80 questions in 3 hours 30 minutes; 70% to pass. Exams taken on or after June 1, 2026 are delivered by CPS HR Consulting through Pearson VUE.
- You can't bring your own books: the NEC, NFPA 70E and Cal/OSHA Pocket Guide are available on the exam screen. Practice finding articles and tables quickly.
- The certification covers residential work only: single-family and multifamily buildings with a utility supply of at most 3-phase 4-wire 120/208 V or 120/240 V.
- If you fail, wait 60 days from the exam date, then send a retest application and the $100 fee.
Frequently asked questions
What's on the California Residential Electrician exam?
80 questions: installation 66%, determination of electrical system requirements 23%, maintenance and repair 6% and safety 5%. The exam may also include trade knowledge.
Can I bring a code book?
No. The NEC 2023, NFPA 70E 2024 and the Cal/OSHA Pocket Guide are provided on screen.
How is it different from the General Electrician exam?
The Residential certificate is limited to residential buildings with a small utility service. The General Electrician exam has 100 questions and covers all work under the NEC.
Free questions with answers
Show all 10 free questions and answers
An electrician sets up a portable extension ladder to reach a second-story service mast. The working length of the ladder (foot to top support) is 20 ft. Where should the foot of the ladder be placed under the Cal/OSHA angle rule?
Answer: 5 ft from the wall
Title 8 section 3276(e)(9) says a non-self-supporting ladder should be set so the horizontal distance from the top support to the foot is one-quarter of the working length. 20 ft / 4 = 5 ft. 2 ft is too steep and 8 or 10 ft is too shallow and invites sliding.
Reference: California Code of Regulations, Title 8 (Cal/OSHA), Section 3276(e)(9)
A portable ladder is used to step off onto a roof edge where a rooftop PV combiner will be wired. How far must the side rails extend above the upper landing surface?
Answer: At least 36 inches above the landing
Title 8 section 3276(e)(11) requires side rails to extend not less than 36 inches above the upper landing surface (or the ladder must be otherwise secured with a grasping device). Shorter extensions leave nothing to hold while stepping on or off.
Reference: California Code of Regulations, Title 8 (Cal/OSHA), Section 3276(e)(11)
A new dwelling has 2,200 ft² of livable floor area plus a 400 ft² attached garage and an open porch. Using 3 VA/ft² under the standard method, what general lighting and general-use receptacle load is calculated?
Answer: 6,600 VA
Section 220.12 and Table 220.12 use 3 VA/ft² for dwellings, and 220.14 / 220.82(B)(1) say the area excludes garages and open porches. 2,200 x 3 = 6,600 VA. Including the garage gives 7,800 VA (2,600 x 3).
Reference: NFPA 70, National Electrical Code, 2023, Section 220.12 and Table 220.12
A duplex has two household electric ranges rated 12 kW each. Using Table 220.55, Column C, what is the demand load for the two ranges?
Answer: 11 kW
Column C of Table 220.55 gives 8 kW for one range and 11 kW for two ranges not over 12 kW rating each. Adding the nameplates (24 kW) ignores demand, and 8 kW is the one-range value.
Reference: NFPA 70, National Electrical Code, 2023, Table 220.55, Column C
A house service supplies these fastened-in-place appliances: a 1,200 VA dishwasher, a 750 VA disposal, a 4,500 VA water heater and an 800 VA trash compactor. Using 220.53, what demand load is used for these appliances?
Answer: 5,438 VA
Section 220.53 permits a 75% demand factor where four or more fastened-in-place appliances (other than ranges, dryers, HVAC) are on the same feeder or service. Sum = 1,200 + 750 + 4,500 + 800 = 7,250 VA; 7,250 x 0.75 = 5,437.5, or about 5,438 VA. 7,250 VA omits the factor.
Reference: NFPA 70, National Electrical Code, 2023, Section 220.53
A utility room in a house has a sink with a receptacle on the wall beside it. Under 210.8(A), GFCI protection is required for that receptacle when it is installed within what distance of the top inside edge of the sink bowl?
Answer: 6 ft
Section 210.8(A)(8) requires GFCI protection for receptacles within 1.8 m (6 ft) of the top inside edge of a sink bowl in a dwelling. The 3-ft distance is the bathroom-receptacle placement rule in 210.52(D), not the GFCI rule.
Reference: NFPA 70, National Electrical Code, 2023, Section 210.8(A)(8)
Five 12/2 NM-B cables (10 current-carrying conductors) pass without spacing through the same bored hole in a top plate that will be sealed with fire caulk. The 90°C ampacity of 12 AWG copper is 30 A. Under 334.80 and Table 310.15(C)(1), what is the adjusted ampacity of each conductor?
Answer: 15 A
Section 334.80 requires the Table 310.15(C)(1) adjustment when more than two NM cables pass without spacing through the same opening that will be sealed, and lets the 90°C rating be the starting point as long as the result does not exceed the 60°C value. 10 conductors = 50%: 30 x 0.50 = 15 A, which is below the 60°C limit of 20 A. 21 A uses the 70% factor (7-9 conductors), 20 A ignores the adjustment, and 10 A wrongly starts from the 60°C value.
Reference: NFPA 70, National Electrical Code, 2023, Section 334.80
An old two-wire receptacle in a 1950s house is being replaced, and there is no equipment grounding conductor in the box. Which replacement is permitted by 406.4(D)(2)?
Answer: A GFCI receptacle marked "No Equipment Ground"
Section 406.4(D)(2) allows a nongrounding receptacle to be replaced with another nongrounding receptacle, with a GFCI receptacle marked "No Equipment Ground", or with a grounding-type receptacle supplied through a GFCI and marked "GFCI Protected" and "No Equipment Ground". Tying the ground terminal to the neutral is never allowed.
Reference: NFPA 70, National Electrical Code, 2023, Section 406.4(D)(2)
The 15-ampere receptacle in a dwelling bedroom is worn and is being replaced on an existing circuit. Which replacement satisfies 406.4(D)(4)?
Answer: A listed outlet branch-circuit type AFCI receptacle
Section 406.4(D)(4) requires a replacement receptacle in an area listed in 210.12 (which includes bedrooms) to be a listed outlet branch-circuit type AFCI receptacle, or to be protected by one or by a listed combination-type AFCI breaker. A GFCI does not provide arc-fault protection.
Reference: NFPA 70, National Electrical Code, 2023, Section 406.4(D)(4)
A worn nongrounding receptacle in a dwelling's living room is replaced by another nongrounding receptacle (no equipment grounding conductor exists in the box). Under 406.4(D)(5), is a tamper-resistant receptacle required?
Answer: No, replacing a nongrounding receptacle with another nongrounding one is an exception
Section 406.4(D)(5) requires tamper-resistant replacements where tamper-resistant receptacles are required elsewhere in the Code, but excepts the replacement of a nongrounding receptacle with another nongrounding receptacle, and CO/ALR receptacles replaced on aluminum conductors.
Reference: NFPA 70, National Electrical Code, 2023, Section 406.4(D)(5)