Requirements at a glance
| Agency | Arkansas Board of Electrical Examiners (Department of Labor and Licensing, Code Enforcement); exams by Prov |
|---|---|
| Experience | 2 years of experience wiring family dwellings up to and including a quadruplex, or a Board-approved combination of training and experience |
| Exam | Residential journeyman electrician (40 questions, 2 hours, 70% to pass, open book) |
| Books allowed | The 2023 National Electrical Code (an older or newer edition is allowed); the exam's own reference list is in the Prov bulletin |
| Fees | $80 per exam (17 CAR 210-403; $56 for paper/pencil), plus Board application and license fees |
Electricians applying to the Arkansas Board of Electrical Examiners for a residential journeyman license: 2 years of experience wiring family dwellings up to and including a quadruplex, or a Board-approved combination of training and experience.
Official links
- Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)
- 17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
- Prov (schedule your exam) (opens in a new tab)
- Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
How to get licensed, step by step
Apply to the Board
Submit your application and experience records to the Board of Electrical Examiners through its online portal. The Board must approve you before you schedule.
Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
Schedule with Prov
After approval, schedule the computer-based exam with Prov and pay the exam fee.
Prov (schedule your exam) (opens in a new tab)Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
Pass the exam
A 70% cut score passes. If you fail, you stay approved and can retest; the bulletin gives a six-month eligibility window and a 1-year retake period, so check the dates with the Board.
Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
Get licensed and renew
Pay the license fee once you pass. Licenses renew with continuing education under 17 CAR 210.
Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
How to prepare
- Prov's bulletin names the 2023 NEC and lets you bring an older or newer edition of an open-book reference. Arkansas amends the NEC for AFCI and GFCI protection and for kitchen island and peninsula receptacles, so learn the Arkansas exceptions in 17 CAR 210-401 for those rules; our questions stick to rules that are the same in every recent NEC edition.
- The exam is open book and timed, with a 70% cut score. Use permanent tabs and pen highlighting only: handwritten notes, loose sticky notes and photocopies are not allowed in a reference book.
- Prov splits this exam by NEC chapter and Chapter 2 (wiring and protection, Articles 210 to 250) carries 18 of 40 questions: focus on Articles 210, 220 Part III, 230, 240 and 250.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 editionEssential
Prov's bulletin names the 2023 NEC and allows an older or newer edition. The Board adopts the NEC with Arkansas exceptions in 17 CAR 210-401.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC). The exam description says 2023 but the reference list prints 2020; older or newer editions are permitted
What's on the exam
Official content outline from Prov (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| NEC Chapter 1 | 4 | |
| Safety | 3 | |
| NEC Chapter 2 | 18 | |
| NEC Chapter 3 | 4 | |
| NEC Chapter 4 | 2 | |
| NEC Chapter 5 | 2 | |
| NEC Chapter 6 | 2 | |
| General Theory | 5 |
Exam day details
- Administered by Prov for the Arkansas Board of Electrical Examiners (Department of Labor and Licensing).
- Fee: $80 for the computer-based exam ($56 paper/pencil) per Prov's bulletin and 17 CAR 210-403. Board application and license fees are separate.
- Prov's bulletin: 40 questions in 2 hours, open book, 70% cut score. Our practice exam uses the same counts; Prov arranges this exam by NEC chapter rather than by subject.
- Computer-based exam from Prov (paper/pencil is cheaper). Apply to the Board of Electrical Examiners first; once it approves you, you schedule with Prov.
- All Prov electrical exams are open book and timed, with a 70% cut score. Books may carry permanent tabs and pen highlighting; handwritten notes and loose sticky notes are not allowed.
- If you fail, you stay approved and can retake the exam. The bulletin gives both a six-month eligibility window after approval and a 1-year retake period, so confirm the dates with the Board.
- Arkansas no longer issues an air-conditioning electrician license (repealed by Act 746 of 2025).
Note: Prov's bulletin names the 2023 NEC for this exam but its reference list prints the 2020 NEC, and the bulletin is dated November 10, 2023. Arkansas also amends the NEC for AFCI, GFCI and kitchen island receptacles. Confirm the edition with the Board and Prov.
Frequently asked questions
What can a residential journeyman electrician do in Arkansas?
Residential licenses cover wiring of family dwellings up to and including a quadruplex. Larger or commercial work needs a journeyman or master license.
What's on the exam?
Eight areas: NEC Chapter 2 wiring and protection (18 questions), general theory (5), NEC Chapter 1 (4), NEC Chapter 3 (4), safety (3) and NEC Chapters 4, 5 and 6 (2 each).
How much experience is required?
2 years of experience wiring family dwellings up to and including a quadruplex, or a combination of training and experience the Board approves (17 CAR 210).
Free questions with answers
Show all 10 free questions and answers
A 120/240-volt residential panelboard is mounted in a hallway with grounded concrete on one side and exposed live parts of another panel on the other side. What is the minimum depth of the clear working space in front of it?
Answer: 3 feet, because the Table 110.26(A)(1) distance for 0 to 150 volts to ground is the same for all three conditions
Table 110.26(A)(1) lists 3 ft for 0 to 150 V to ground under Conditions 1, 2 and 3 alike. A 120/240-V system has 120 V to ground, so no condition changes the depth. The 3.5 ft and 4 ft figures apply to the higher 151 to 600 V column.
Reference: NFPA 70, National Electrical Code, Table 110.26(A)(1)
Which method of securing a box or other equipment to a masonry wall violates the general mounting rule in 110.13(A)?
Answer: Driving wooden plugs into holes in the masonry and screwing the equipment to them
Section 110.13(A) requires equipment to be firmly secured to the surface on which it is mounted, and it prohibits wooden plugs driven into holes in masonry, concrete, plaster or similar materials as the means of attachment. Wood shrinks and loosens. Anchors, studs and toggles are accepted mechanical fastening means.
Reference: NFPA 70, National Electrical Code, 110.13(A)
A one-family dwelling has 2,400 sq ft of floor area. It has two 20-ampere small-appliance circuits and one laundry circuit. Using the standard method and the Article 220 lighting demand factors for dwelling units, what is the demand-adjusted general lighting, small-appliance and laundry load?
Answer: 6,045 VA
General lighting 2,400 x 3 VA = 7,200 VA; small appliance 2 x 1,500 = 3,000 VA; laundry 1,500 VA; total 11,700 VA. Dwelling lighting demand factors (Table 220.42 in the 2020 NEC, Table 220.45 in the 2023 NEC): first 3,000 VA at 100% = 3,000; remaining 8,700 VA x 35% = 3,045; total 6,045 VA. 4,095 applies 35% to everything, 6,480 uses 40%, and 11,700 applies no demand factor.
Reference: NFPA 70, National Electrical Code, Article 220: 3 VA/sq ft dwelling lighting load, 220.52, and dwelling lighting demand factors (Table 220.42 in the 2020 NEC, Table 220.45 in the 2023 NEC)
A heating element has a resistance of 20 ohms and carries 6 amperes. How much power does it use?
Answer: 720 watts
Power equals current squared times resistance: 6 x 6 x 20 = 720 W. Multiplying current by resistance (6 x 20 = 120) gives a voltage of 120 V, not watts. 36 forgets the resistance, and 1,200 mixes up the factors.
Reference: NFPA 70, National Electrical Code, Electrical theory: P = I squared x R
A dwelling has 9,000 VA of electric heating and a 4,500-VA air conditioner that cannot run at the same time because they are interlocked. What does 220.60 permit when calculating the load?
Answer: Omit the smaller load and include only the 9,000-VA heating load
Section 220.60 allows the smaller of two noncoincident loads to be left out of the total. Here the larger 9,000-VA heating load is counted and the 4,500-VA A/C is omitted. The 75-percent factor in 220.53 is for fixed appliances, not for heating and cooling.
Reference: NFPA 70, National Electrical Code, 220.60
Two 120-volt loads rated 1,200 watts and 1,800 watts are connected in parallel across one 120-volt circuit. What is the total current drawn?
Answer: 25 amperes
Total power is 1,200 + 1,800 = 3,000 W. I = P / V = 3,000 / 120 = 25 A. 12.5 A results from dividing by 240 V, 15 A is the larger load alone, and 50 is a doubling mistake.
Reference: NFPA 70, National Electrical Code, Electrical theory: I = P / V
A 3 x 2 x 3 1/2 inch device box (18.0 cubic inches) holds two 12-2 NM cables with ground, a single-pole switch, and internal cable clamps. All four insulated conductors terminate or splice in the box. What total box fill volume must be counted for 12 AWG conductors?
Answer: 18.0 cubic inches
Each 12 AWG conductor allowance is 2.25 cu in. Four insulated conductors = 4 x 2.25 = 9.0; all grounds together = 1 x 2.25; all internal clamps together = 1 x 2.25; the switch yoke = 2 x 2.25 = 4.5. Total 9.0 + 2.25 + 2.25 + 4.5 = 18.0 cu in, which exactly fills the box. 15.75 omits the clamps, 13.5 omits the switch, and 20.25 counts each ground separately.
Reference: NFPA 70, National Electrical Code, 314.16(B)
A 15-ampere, 125-volt receptacle is installed on an exterior wall where it is exposed to rain, making it a wet location. What cover type does 406.9(B) require?
Answer: An enclosure that is weatherproof whether or not a plug is inserted
Section 406.9(B)(1) requires 15- and 20-A, 125- and 250-V receptacles in a wet location to be in a weatherproof enclosure whether or not an attachment plug is inserted (an in-use cover). A flat plate cover is for damp locations only, where the area is protected from the weather. A weather-resistant receptacle does not replace the cover.
Reference: NFPA 70, National Electrical Code, 406.9(B)(1)
A temporary power installation for a seasonal outdoor event (not a construction site) needs a splice in its branch-circuit conductors. What does 590.4(G) require for the splice?
Answer: A box, conduit body or other enclosure with a cover
590.4(G) requires a box, conduit body or other enclosure with a cover installed for all splices in temporary wiring. Its exceptions apply only on construction sites (for example, splices made entirely within nonmetallic multiconductor cords or cables, or GFCI-protected circuits in framed walls), so they do not apply here. A connector alone or tape does not meet the rule.
Reference: NFPA 70, National Electrical Code, 590.4(G)
A pool pump motor is connected with a flexible cord and plug, as 680.21(A) permits. What is the maximum length of the cord?
Answer: 3 feet, which keeps the cord short and protected
680.21(A) allows pool-associated motors to use cord-and-plug connections, but the flexible cord may not exceed 900 mm (3 ft) in length (680.21(A)(2) in the 2023 NEC; the item number differs in other editions). A 6 ft appliance-cord length and 10 ft are common wrong guesses; the receptacle must therefore be near the motor.
Reference: NFPA 70, National Electrical Code, 680.21(A)
Sources
- Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)
- 17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
- Prov: Arkansas electrical candidate information bulletin (2023.11.10, archived copy) (opens in a new tab)
Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.