Requirements at a glance
| Agency | Arkansas Board of Electrical Examiners (Department of Labor and Licensing, Code Enforcement); exams by Prov |
|---|---|
| Experience | 2 years of experience under an engineer or licensed electrician in maintaining electrical conductors and equipment, or a Board-approved combination of training and experience |
| Exam | Industrial maintenance electrician (50 questions, 2 hours, 70% to pass, open book) |
| Books allowed | The 2023 NEC, the NCCER Basic Safety, Industrial Maintenance Electrical & Instrumentation, Standby and Emergency Systems, E & I Drawings and Motor Controls books, and the American Electrician's Handbook (17th Edition) |
| Fees | $80 per exam per Prov's bulletin ($56 paper/pencil); 17 CAR 210-403 lists $50 for this exam, so confirm with the Board. Plus Board application and license fees |
Electricians applying to the Arkansas Board of Electrical Examiners for an industrial maintenance license, which is limited to the repair, maintenance, alteration and extension of electrical conductors and equipment for power and control systems in industrial, manufacturing or similar facilities. Applicants need 2 years of experience under an engineer or licensed electrician in maintaining electrical conductors and equipment, or a Board-approved combination of training and experience.
Official links
- Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)
- 17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
- Prov (schedule your exam) (opens in a new tab)
- Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
How to get licensed, step by step
Apply to the Board
Submit your application and experience records to the Board of Electrical Examiners through its online portal. The Board must approve you before you schedule.
Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
Schedule with Prov
After approval, schedule the computer-based exam with Prov and pay the exam fee.
Prov (schedule your exam) (opens in a new tab)Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
Pass the exam
A 70% cut score passes. If you fail, you stay approved and can retest; the bulletin gives a six-month eligibility window and a 1-year retake period, so check the dates with the Board.
Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
Get licensed and renew
Pay the license fee once you pass. Licenses renew with continuing education under 17 CAR 210.
Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
How to prepare
- Prov's bulletin names the 2023 NEC and lets you bring an older or newer edition of an open-book reference. Arkansas amends the NEC for AFCI and GFCI protection and for kitchen island and peninsula receptacles, so learn the Arkansas exceptions in 17 CAR 210-401 for those rules; our questions stick to rules that are the same in every recent NEC edition.
- The exam is open book and timed, with a 70% cut score. Use permanent tabs and pen highlighting only: handwritten notes, loose sticky notes and photocopies are not allowed in a reference book.
- The exam follows NCCER industrial maintenance topics (safety, test instruments, theory, motor controls, standby systems, blueprints) as much as the NEC. Prov lists the NCCER books as references.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 editionEssential
Prov's bulletin names the 2023 NEC and allows an older or newer edition. The Board adopts the NEC with Arkansas exceptions in 17 CAR 210-401.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 edition (older or newer editions are permitted under Prov's open-book rules)
- Basic Safety (NCCER, ISBN 9781323676189)
- Industrial Maintenance Electrical & Instrumentation Level 1 (2007, ISBN 978-0-13-228606-0) and Level 2 (2008, ISBN 978-0-13-614390-1)
- American Electrician's Handbook, 17th Edition (ISBN 978-1260457919)
- Standby and Emergency Systems (2009, ISBN 978-0-13-609163-9)
- E & I Drawings (2009)
- Motor Controls (ISBN 978-0-13-604697-4)
What's on the exam
Official content outline from Prov (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Basic Safety | 4 | |
| Introduction to Construction Math | 2 | |
| Introduction to Test Instruments | 2 | |
| Hazardous Locations | 2 | |
| Specialty Transformers | 1 | |
| Electrical Safety | 4 | |
| Hand Bending | 2 | |
| Electrical Theory: Two | 5 | |
| Electrical Test Equipment | 4 | |
| Introduction to Electrical Blueprints | 3 | |
| Wiring: Commercial and Industrial | 5 | |
| Grounding | 4 | |
| Conductor Terminations and Splices | 3 | |
| Circuit Breakers and Fuses | 3 | |
| Motor Controls | 4 | |
| Standby and Emergency Systems | 2 |
Exam day details
- Administered by Prov for the Arkansas Board of Electrical Examiners (Department of Labor and Licensing).
- Fee: $80 for the computer-based exam ($56 paper/pencil) per Prov's bulletin; 17 CAR 210-403 lists $50 for this exam. Board application and license fees are separate.
- Prov's bulletin: 50 questions in 2 hours, open book, 70% cut score. Our practice exam uses the same counts and the same sixteen subject areas, which follow the NCCER industrial maintenance books.
- Computer-based exam from Prov (paper/pencil is cheaper). Apply to the Board of Electrical Examiners first; once it approves you, you schedule with Prov.
- All Prov electrical exams are open book and timed, with a 70% cut score. Books may carry permanent tabs and pen highlighting; handwritten notes and loose sticky notes are not allowed.
- If you fail, you stay approved and can retake the exam. The bulletin gives both a six-month eligibility window after approval and a 1-year retake period, so confirm the dates with the Board.
- Arkansas no longer issues an air-conditioning electrician license (repealed by Act 746 of 2025).
Note: Prov's bulletin charges $80 for every electrical exam, but 17 CAR 210-403 lists $50 for the industrial maintenance exam, so confirm the fee with the Board. The bulletin is dated November 10, 2023, and the exam leans on NCCER books we do not reproduce; our questions rest on the 2023 NEC and general industrial maintenance practice.
Frequently asked questions
What's on the Arkansas industrial maintenance electrician exam?
Sixteen small subject areas. The largest are electrical theory two (5 questions), wiring for commercial and industrial (5), and basic safety, electrical safety, electrical test equipment, grounding and motor controls (4 each).
What can an industrial maintenance electrician do?
Repair, maintenance, alteration and extension of electrical conductors and equipment for power and control systems in industrial, manufacturing or similar facilities (17 CAR 210-101).
Which books are allowed?
The 2023 NEC, the NCCER Basic Safety, Industrial Maintenance Electrical & Instrumentation Level 1 and Level 2, Standby and Emergency Systems, E & I Drawings and Motor Controls books, and the American Electrician's Handbook (17th Edition).
Free questions with answers
Show all 10 free questions and answers
A non-self-supporting extension ladder rests against a wall at a point 16 feet above the floor. For the standard setup, the horizontal distance from the foot to the wall is one quarter of the working length. Treating the 16 ft as the working length, how far from the wall is the base placed?
Answer: 4 feet
Non-self-supporting ladders are set at an angle so that the horizontal distance from the top support to the foot is about one quarter of the working length (29 CFR 1926.1053(b)(5)(i)). One quarter of 16 ft is 4 ft. 2 ft is too steep, and 6 ft or 8 ft makes the ladder too flat and weakens it.
Reference: 29 CFR 1926 (OSHA construction standards), 1926.1053(b)(5)(i)
A crew installs temporary protective grounds on a de-energized 4,160-volt bus after verifying no voltage. What is the correct order of attachment?
Answer: Connect the clamp to the grounding point first, then to the conductor; remove in the reverse order
The ground end is attached first so that any voltage that appears while the conductor end is being connected is already tied to earth. Removal is the reverse, ground end last. Grounds are only placed after the circuit has been tested dead.
Reference: Standard electrical principle (not a code section), General principle
What is the inductive reactance of a 0.05-henry coil at 60 hertz?
Answer: 18.85 ohms
XL = 2 x pi x f x L = 2 x 3.1416 x 60 x 0.05 = 18.85 ohms. 3.00 ohms leaves out the 2 x pi factor (60 x 0.05). 188.5 ohms is off by a factor of ten. 0.053 ohms comes from taking the reciprocal.
Reference: Standard electrical principle (not a code section), General principle
A technician will test a motor winding with a megohmmeter. The motor is fed by a variable frequency drive. What must be done before applying the test voltage?
Answer: Lock out the circuit and disconnect the motor leads from the drive
Insulation resistance tests apply several hundred to thousands of volts, which will destroy drive electronics connected to the circuit. The circuit must be de-energized, locked out, isolated from the drive, and discharged after the test. Shorted leads give no insulation reading between winding and frame.
Reference: Standard electrical principle (not a code section), General principle
On a floor plan drawn to a scale of 1/4 inch = 1 foot, a conduit run measures 3 inches. How long is the run?
Answer: 12 feet
Each 1/4 inch on the drawing is 1 ft, so 3 in / (1/4 in per ft) = 12 ft. 6 ft results from using 1/2 inch per foot, 24 ft from using 1/8 inch per foot, and 36 ft from treating each drawing inch as 12 ft.
Reference: Standard electrical principle (not a code section), General principle
What is the maximum percent fill of a conduit by cross-sectional area when it contains five conductors of the same size?
Answer: 40 percent
Chapter 9, Table 1 sets the fill limit by number of conductors: 53 percent for one, 31 percent for two and 40 percent for over two. Five conductors fall in the over-two group, so 40 percent. 31 percent applies to exactly two conductors, and 53 percent to one.
Reference: NFPA 70, National Electrical Code, Chapter 9, Table 1
What is the minimum length of a rod-type grounding electrode in the NEC?
Answer: 8 feet in length, in contact with the earth
Section 250.52(A)(5) requires rod and pipe electrodes to be not less than 8 ft (2.44 m) in length, and 250.53(A)(4) requires them to be installed so at least 8 ft of length is in contact with the soil. Where rock is encountered, the rod may be driven at an angle of up to 45 degrees or buried in a trench at least 30 in deep.
Reference: NFPA 70, National Electrical Code, 250.52(A)(5)
Where a manufacturer indicates a numeric tightening torque for a terminal on a motor control center bucket, what does the NEC require?
Answer: The torque value must be achieved using an approved means, such as a torque tool
Section 110.14(D) requires that terminal tightening torque values indicated on the equipment or in the manufacturer's instructions be reached using an approved means, such as a torque tool or a shear-bolt type device with a visual indicator. Loose terminals cause heat, and over-tightening can damage conductors and lugs.
Reference: NFPA 70, National Electrical Code, 110.14(D)
What is the maximum standard overcurrent device rating allowed for 12 AWG copper conductors supplying a general (non-motor) load, applying the small-conductor rule?
Answer: 20 amperes
Section 240.4(D) limits overcurrent protection for small conductors: 14 AWG copper 15 A, 12 AWG copper 20 A and 10 AWG copper 30 A (after any ambient or bundling adjustment). 15 A is the limit for 14 AWG, and 30 A is for 10 AWG.
Reference: NFPA 70, National Electrical Code, 240.4(D)
A 25-hp, 460-volt motor has a nameplate full-load current of 32 amperes and a marked service factor of 1.15. What is the maximum trip current setting of a separate overload device under 430.32(A)(1)?
Answer: 40 amperes
For motors with a service factor of 1.15 or greater, or a temperature rise of 40 C or less, the overload device is selected to trip at no more than 125 percent of the nameplate current: 32 x 1.25 = 40 A. 36.8 A uses the 115 percent figure (for other motors), 32 A is the nameplate current itself, and 48 A uses 150 percent.
Reference: NFPA 70, National Electrical Code, 430.32(A)(1)
Sources
- Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)
- 17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
- Prov: Arkansas electrical candidate information bulletin (2023.11.10, archived copy) (opens in a new tab)
Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.