Requirements at a glance
| Agency | Arkansas Board of Electrical Examiners (Department of Labor and Licensing, Code Enforcement); exams by Prov |
|---|---|
| Experience | A completed 4-year approved apprenticeship, or 8 years (16,000 hours) of electrical construction experience or Board-approved training |
| Exam | Journeyman electrician (60 questions, 3 hours, 70% to pass, open book) |
| Books allowed | The 2023 National Electrical Code (an older or newer edition is allowed); the exam's own reference list is in the Prov bulletin |
| Fees | $80 per exam (17 CAR 210-403; $56 for paper/pencil), plus Board application and license fees |
Electricians applying to the Arkansas Board of Electrical Examiners for a journeyman license: a completed 4-year approved apprenticeship, or 8 years (16,000 hours) of electrical construction experience or Board-approved training.
Official links
- Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)
- 17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
- Prov (schedule your exam) (opens in a new tab)
- Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
How to get licensed, step by step
Apply to the Board
Submit your application and experience records to the Board of Electrical Examiners through its online portal. The Board must approve you before you schedule.
Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
Schedule with Prov
After approval, schedule the computer-based exam with Prov and pay the exam fee.
Prov (schedule your exam) (opens in a new tab)Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
Pass the exam
A 70% cut score passes. If you fail, you stay approved and can retest; the bulletin gives a six-month eligibility window and a 1-year retake period, so check the dates with the Board.
Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
Get licensed and renew
Pay the license fee once you pass. Licenses renew with continuing education under 17 CAR 210.
Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
How to prepare
- Prov's bulletin names the 2023 NEC and lets you bring an older or newer edition of an open-book reference. Arkansas amends the NEC for AFCI and GFCI protection and for kitchen island and peninsula receptacles, so learn the Arkansas exceptions in 17 CAR 210-401 for those rules; our questions stick to rules that are the same in every recent NEC edition.
- The exam is open book and timed, with a 70% cut score. Use permanent tabs and pen highlighting only: handwritten notes, loose sticky notes and photocopies are not allowed in a reference book.
- General knowledge and calculations, service, feeders and overcurrent protection and raceways and enclosures carry the most questions: tab Articles 250, 215, 220, 230, 240 and 300 to 358 and the Chapter 9 tables.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 editionEssential
Prov's bulletin names the 2023 NEC and allows an older or newer edition. The Board adopts the NEC with Arkansas exceptions in 17 CAR 210-401.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 edition (older or newer editions are permitted under Prov's open-book rules)
What's on the exam
Official content outline from Prov (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Grounding and Bonding | 6 | |
| General Knowledge of the Electrical Trade and Calculations | 9 | |
| Service, Feeders, Branch Feeders and Overcurrent Protection | 8 | |
| Raceways and Enclosures | 8 | |
| Conductors | 7 | |
| Motors and Controls | 7 | |
| Utilization and General Use Equipment | 6 | |
| Special Occupancies and Equipment | 4 | |
| Low Voltage Circuits, Including Alarms and Communications | 2 | |
| Safety | 3 |
Exam day details
- Administered by Prov for the Arkansas Board of Electrical Examiners (Department of Labor and Licensing).
- Fee: $80 for the computer-based exam ($56 paper/pencil) per Prov's bulletin and 17 CAR 210-403. Board application and license fees are separate.
- Prov's bulletin: 60 questions in 3 hours, open book, 70% cut score. Our practice exam uses the same counts and the same ten subject areas.
- Computer-based exam from Prov (paper/pencil is cheaper). Apply to the Board of Electrical Examiners first; once it approves you, you schedule with Prov.
- All Prov electrical exams are open book and timed, with a 70% cut score. Books may carry permanent tabs and pen highlighting; handwritten notes and loose sticky notes are not allowed.
- If you fail, you stay approved and can retake the exam. The bulletin gives both a six-month eligibility window after approval and a 1-year retake period, so confirm the dates with the Board.
- Arkansas no longer issues an air-conditioning electrician license (repealed by Act 746 of 2025).
Note: Format, subject areas and the 2023 NEC come from Prov's electrical bulletin dated November 10, 2023, which may have been revised since. Prov lets you bring an older or newer NEC edition, but Arkansas amends the NEC for AFCI, GFCI and kitchen island receptacles, so confirm the edition and amendments with the Board and Prov.
Frequently asked questions
What's on the Arkansas journeyman electrician exam?
Ten subject areas with these question counts: general knowledge of the electrical trade and calculations (9), service, feeders, branch feeders and overcurrent protection (8), raceways and enclosures (8), conductors (7), motors and controls (7), grounding and bonding (6), utilization and general use equipment (6), special occupancies and equipment (4), safety (3) and low voltage circuits including alarms and communications (2).
Which NEC edition does the Arkansas exam use?
Prov's bulletin says the 2023 NEC, and Prov permits older or newer editions of an open-book reference. Arkansas amends the NEC for AFCI, GFCI and kitchen island receptacles, so check the Board's exceptions too.
How much experience does an Arkansas journeyman electrician need?
A completed 4-year approved apprenticeship, or 8 years (16,000 hours, at most 2,000 hours credit per year) of electrical construction experience or Board-approved training. Reciprocity is available from a state where you were tested and held a journeyman license for one year.
Free questions with answers
Show all 10 free questions and answers
A disconnect is mounted on a wall behind stored materials that must be moved or climbed over to reach it. Which Article 100 term does this disconnect fail to meet?
Answer: Readily accessible
Readily accessible means capable of being reached quickly for operation, renewal or inspection without having to climb over or remove obstacles or resort to portable ladders. A disconnect blocked by stored material may still be reachable by moving the obstacles, but it is not readily accessible.
Reference: NFPA 70, National Electrical Code, Article 100, Definitions (Readily Accessible)
Equipment rated 1,200 amperes or more and over 6 feet wide, containing overcurrent devices, switching devices or control devices, is installed in a switchgear room. What entrance arrangement does 110.26(C)(2) require for the working space?
Answer: One entrance at each end of the working space, each at least 24 inches wide and 6.5 feet high
For large equipment rated 1,200 A or more and wider than 6 ft, 110.26(C)(2) requires an entrance at each end of the working space (with limited exceptions), each at least 24 in wide and 6.5 ft high, so a worker cannot be trapped by an arc flash. A single entrance is allowed only under the specific exceptions for a continuous and unobstructed way out.
Reference: NFPA 70, National Electrical Code, 110.26(C)(2)
Six-AWG copper THWN-2 conductors (90 degrees C insulation) supply a load through equipment whose terminals are rated 75 degrees C only. What is the maximum ampacity that may be used to size the overcurrent device for this circuit if no adjustment or correction factors apply?
Answer: 65 amperes, the 75 degrees C column value
Section 110.14(C) limits the ampacity to the temperature rating of the lowest-rated terminal. For 6 AWG copper in Table 310.16 the values are 55 A at 60 degrees C, 65 A at 75 degrees C and 75 A at 90 degrees C. The 90 degrees C value may be used only as a starting point for derating, not as the final ampacity at 75 degrees C terminals.
Reference: NFPA 70, National Electrical Code, 110.14(C) and Table 310.16
What minimum length of rod electrode must be in contact with the soil under the NEC rules for rod and pipe electrodes?
Answer: 8 feet
Rod and pipe electrodes must be at least 8 ft long and installed so that 8 ft is in contact with the soil. This is in 250.52(A)(5) with installation details in 250.53. Where rock bottom prevents driving vertically, the rod may be driven at an angle up to 45 degrees or buried in a trench at least 30 in deep.
Reference: NFPA 70, National Electrical Code, 250.52(A)(5) and 250.53
What is the maximum overcurrent protection normally permitted for 10 AWG copper conductors supplying a general branch circuit under the small conductor rule in 240.4(D)?
Answer: 30 amperes
Section 240.4(D) limits overcurrent protection to 15 A for 14 AWG, 20 A for 12 AWG and 30 A for 10 AWG copper, even where the table ampacity of the conductor is higher. This is why a 35 A table ampacity does not justify a 35 A breaker on 10 AWG for the circuits covered by the rule.
Reference: NFPA 70, National Electrical Code, 240.4(D)
What is the maximum total bends permitted in a run of EMT between pull points, such as between two conduit bodies?
Answer: 360 degrees
Section 358.26 limits a run of EMT between pull points (conduit bodies, boxes or terminations) to no more than the equivalent of four quarter bends, or 360 degrees total, including offsets. More bends make pulling conductors difficult and damage insulation.
Reference: NFPA 70, National Electrical Code, 358.26
A 4,500-watt, 240-volt fixed storage water heater with a single heating element is installed. Under 422.13, what is the minimum branch-circuit rating, and which standard overcurrent device is selected?
Answer: 23.4 A minimum; a 25-ampere breaker is the smallest standard size that meets it
Section 422.13 requires the branch circuit for a fixed storage-type water heater of 120 gallons or less to be rated at least 125 percent of the nameplate rating. I = 4,500 / 240 = 18.75 A, and 18.75 x 1.25 = 23.4 A. The smallest standard rating at or above 23.4 A is 25 A (240.6(A)). A 20 A breaker would be below the minimum.
Reference: NFPA 70, National Electrical Code, 422.13 and 240.6(A)
Which hazardous (classified) location class involves easily ignitable fibers or flyings, such as cotton lint in a textile mill?
Answer: Class III
Article 500 classifies locations by the type of hazardous material: Class I is flammable gases or vapors, Class II is combustible dust, and Class III is easily ignitable fibers or flyings that are not likely to be suspended in the air in quantities to produce ignitable mixtures. There is no Class IV.
Reference: NFPA 70, National Electrical Code, 500.5(A) and 500.5(D)
Using Table 430.250, a 10-horsepower, three-phase, 460-volt induction motor has a full-load current of 14 amperes. What is the minimum ampacity of the branch-circuit conductors under 430.22?
Answer: 17.5 amperes
Section 430.22 requires branch-circuit conductors supplying a single continuous-duty motor to have an ampacity of at least 125 percent of the motor full-load current taken from the table (not the nameplate, per 430.6(A)(1)): 14 x 1.25 = 17.5 A. Using 14 A ignores the 125 percent, 16.1 A uses 115 percent, and 35 A multiplies by the 250 percent used for breaker sizing.
Reference: NFPA 70, National Electrical Code, 430.22 and Table 430.250
What is the smallest copper bonding conductor or grounding electrode conductor permitted for the primary protector of a communications cable under Article 800?
Answer: 14 AWG
800.100(A)(3) sets the minimum at 14 AWG, with a current-carrying capacity not less than the aggregate of the cable's grounded metal sheath and protected conductors, and it need not exceed 6 AWG. 18 AWG is a typical communications conductor size but is too small for bonding; 12 and 10 AWG are larger than the minimum requires.
Reference: 2023 National Electrical Code, 800.100(A)(3)
Sources
- Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)