Requirements at a glance
| Agency | Arkansas Board of Electrical Examiners (Department of Labor and Licensing, Code Enforcement); exams by Prov |
|---|---|
| Experience | 1 year of experience with an electrical sign company or licensed electrician installing, maintaining and repairing signs and gaseous tubing, or a Board-approved equivalent (the specialist sign electrician license in 17 CAR 210) |
| Exam | Master sign electrician (40 questions, 2 hours, 70% to pass, open book) |
| Books allowed | The 2023 National Electrical Code (an older or newer edition is allowed); the exam's own reference list is in the Prov bulletin |
| Fees | $80 per exam (17 CAR 210-403; $56 for paper/pencil), plus Board application and license fees |
Electricians applying to the Arkansas Board of Electrical Examiners for a sign license (the specialist sign electrician in 17 CAR 210), which covers installing, maintaining and repairing electrically illuminated or operated signs and gaseous tubing for illumination, with connection to an approved outlet within 25 feet of the sign. Applicants need 1 year of experience with an electrical sign company or licensed electrician, or a Board-approved equivalent.
Official links
- Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)
- 17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
- Prov (schedule your exam) (opens in a new tab)
- Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
How to get licensed, step by step
Apply to the Board
Submit your application and experience records to the Board of Electrical Examiners through its online portal. The Board must approve you before you schedule.
Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
Schedule with Prov
After approval, schedule the computer-based exam with Prov and pay the exam fee.
Prov (schedule your exam) (opens in a new tab)Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
Pass the exam
A 70% cut score passes. If you fail, you stay approved and can retest; the bulletin gives a six-month eligibility window and a 1-year retake period, so check the dates with the Board.
Prov: Arkansas electrical candidate bulletin (2023.11.10, archived copy) (opens in a new tab)
Get licensed and renew
Pay the license fee once you pass. Licenses renew with continuing education under 17 CAR 210.
Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
How to prepare
- Prov's bulletin names the 2023 NEC and lets you bring an older or newer edition of an open-book reference. Arkansas amends the NEC for AFCI and GFCI protection and for kitchen island and peninsula receptacles, so learn the Arkansas exceptions in 17 CAR 210-401 for those rules; our questions stick to rules that are the same in every recent NEC edition.
- The exam is open book and timed, with a 70% cut score. Use permanent tabs and pen highlighting only: handwritten notes, loose sticky notes and photocopies are not allowed in a reference book.
- Electrical signs and outline lighting (NEC Article 600) and electrical materials and installation are 12 questions each. A separate 20-question exam covers the parking lot lighting endorsement.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 editionEssential
Prov's bulletin names the 2023 NEC and allows an older or newer edition. The Board adopts the NEC with Arkansas exceptions in 17 CAR 210-401.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 edition (older or newer editions are permitted under Prov's open-book rules)
What's on the exam
Official content outline from Prov (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Basic Electricity & Wiring | 10 | |
| Electrical Materials and Installation | 12 | |
| Electrical Signs and Outline Lighting | 12 | |
| Motors & Transformers | 2 | |
| Outside Branch Circuits and Feeders | 4 |
Exam day details
- Administered by Prov for the Arkansas Board of Electrical Examiners (Department of Labor and Licensing).
- Fee: $80 for the computer-based exam ($56 paper/pencil) per Prov's bulletin and 17 CAR 210-403. Board application and license fees are separate.
- Prov's bulletin: 40 questions in 2 hours, open book, 70% cut score. Our practice exam uses the same counts and the same five subject areas.
- A separate 20-question, 1-hour Prov exam covers the parking lot lighting endorsement; we do not cover it.
- Computer-based exam from Prov (paper/pencil is cheaper). Apply to the Board of Electrical Examiners first; once it approves you, you schedule with Prov.
- All Prov electrical exams are open book and timed, with a 70% cut score. Books may carry permanent tabs and pen highlighting; handwritten notes and loose sticky notes are not allowed.
- If you fail, you stay approved and can retake the exam. The bulletin gives both a six-month eligibility window after approval and a 1-year retake period, so confirm the dates with the Board.
- Arkansas no longer issues an air-conditioning electrician license (repealed by Act 746 of 2025).
Note: 17 CAR 210 calls this license the specialist sign electrician and exempts experienced applicants from the exam in one subsection, while Prov's bulletin lists a Master Sign Electrician exam. Confirm with the Board which exam you must take. The bulletin is dated November 10, 2023.
Frequently asked questions
What's on the Arkansas master sign electrician exam?
Five subject areas: electrical materials and installation (12 questions), electrical signs and outline lighting (12), basic electricity and wiring (10), outside branch circuits and feeders (4) and motors and transformers (2).
What can a sign electrician do?
Install, maintain and repair electrically illuminated or operated signs and gaseous tubing for illumination, connecting to an approved outlet within 25 feet of the sign. A sign electrician may also maintain and repair parking lot lights after passing a separate exam.
Which NEC edition does the exam use?
Prov's bulletin says the 2023 NEC, and Prov permits older or newer editions of an open-book reference.
Free questions with answers
Show all 10 free questions and answers
What is the maximum rating of a branch circuit that supplies a neon tubing installation?
Answer: 30 amperes
Section 600.5(C) caps branch circuits by sign type: neon tubing installations may not be rated over 30 amperes, while all other signs and outline lighting are limited to 20 amperes. 20 amperes is the limit for the non-neon signs, which is why it is the most tempting wrong choice. Neither 40 nor 50 amperes is permitted for sign branch circuits.
Reference: 2023 NFPA 70 National Electrical Code, 600.5(C)
A strip mall has a tenant space with a customer entrance open to the public. Which requirement applies to the sign outlet for that entrance?
Answer: An accessible outlet at the entrance, supplied by a branch circuit of at least 20 amperes that supplies no other load
Section 600.5(A) requires each commercial occupancy accessible to pedestrians to have at least one accessible outlet at each tenant-space entrance for sign or outline lighting use. It must be on a branch circuit rated at least 20 amperes that supplies no other load, although loads directly related to sign control (such as a controller) may be on it. Shared or smaller circuits do not meet the rule.
Reference: 2023 NFPA 70 National Electrical Code, 600.5(A)
An open overhead span of individual copper conductors will cross 40 feet between two supports with no messenger wire. What is the smallest copper conductor permitted?
Answer: 10 AWG
Section 225.6(A) requires open individual overhead conductors to be not smaller than 10 AWG copper (8 AWG aluminum) for spans up to 50 feet, and 8 AWG copper (6 AWG aluminum) for longer spans unless supported by a messenger wire. A 40 foot span falls in the first group, so 10 AWG copper is the minimum.
Reference: 2023 NFPA 70 National Electrical Code, 225.6(A)
A pole that supports only a sign installed under Article 600 is fed by a feeder. Where may the building or structure disconnecting means for that pole be located?
Answer: Elsewhere on the premises, as poles supporting only signs are excepted from the nearest-entrance rule
Section 225.31(B), Exception No. 4 (2023 numbering) says the disconnecting means for poles or similar structures used only for the support of signs installed in accordance with 600.1 may be located elsewhere on the premises. Remember that 600.6 still requires the sign itself to have its own disconnect, located or marked as that section describes.
Reference: 2023 NFPA 70 National Electrical Code, 225.31(B), Exception No. 4
A single-phase 230-volt, 5 hp continuous-duty motor has a branch circuit supplying only that motor. Table 430.248 lists 28 amperes for this motor. What is the minimum ampacity of the branch-circuit conductors?
Answer: 35 amperes
Section 430.22 requires conductors supplying a single continuous-duty motor to have an ampacity of at least 125 percent of the full-load current from the table (430.6(A)(1)). 28 A x 1.25 = 35 A. Using 28 A omits the 125 percent factor, and 42 A applies 150 percent.
Reference: 2023 NFPA 70 National Electrical Code, 430.22 and Table 430.248
Two parallel branches of 12 ohms and 24 ohms are connected across a supply. What is the equivalent resistance?
Answer: 8 ohms
For two parallel resistors R = (R1 x R2) / (R1 + R2) = (12 x 24) / (12 + 24) = 288 / 36 = 8 ohms. Adding them gives 36 ohms (series), averaging gives 18 ohms, and 12 ohms is simply the smaller branch; parallel resistance is always less than the smallest branch.
Reference: Standard electrical principle (not a code section), Parallel circuit resistance
A 2-wire, single-phase circuit uses 12 AWG copper (6,530 circular mils) and carries 16 amperes over 100 feet one way. Using K = 12.9 for copper, what is the approximate voltage drop?
Answer: 6.32 volts
Voltage drop = (2 x K x I x L) / CM = (2 x 12.9 x 16 x 100) / 6,530 = 41,280 / 6,530 = 6.32 V. Leaving out the factor of 2 for the return conductor gives 3.16 V, while 12.64 V and 25.3 V double or quadruple the correct figure.
Reference: Standard electrical principle (not a code section), Voltage drop formula
What is the maximum distance from an outlet box or cabinet to the first support of a run of EMT, without using an exception?
Answer: 3 feet
Section 358.30(A) requires EMT to be securely fastened within 3 feet (900 mm) of each outlet box, junction box, device box, cabinet, conduit body or other termination, and at intervals not exceeding 10 feet. The 5 foot figure applies only under Exception No. 1 where structural members do not readily permit fastening within 3 feet.
Reference: 2023 NFPA 70 National Electrical Code, 358.30(A)
Rigid PVC conduit is installed on a long exterior wall in direct sun. At what expected length change must an expansion fitting be provided?
Answer: 1/4 inch or more
Section 352.44(A) requires expansion fittings for PVC conduit where the expected length change from temperature, per Table 352.44(A), is 1/4 inch (6 mm) or greater in a straight run between securely mounted items such as boxes, cabinets or elbows. PVC expands far more than metal conduit, which is why the rule exists.
Reference: 2023 NFPA 70 National Electrical Code, 352.44(A)
Using Table 314.16(B)(1), how much free box volume must be allowed for each 10 AWG conductor?
Answer: 2.50 cubic inches
Table 314.16(B)(1) lists 2.50 cubic inches for each 10 AWG conductor. The table lists 2.00 for 14 AWG and 2.25 for 12 AWG, and the numbers rise as the conductors get larger.
Reference: 2023 NFPA 70 National Electrical Code, Table 314.16(B)(1)
Sources
- Arkansas Department of Labor and Licensing: Electrical licensing (opens in a new tab)
- 17 CAR Part 210: Board of Electrical Examiners rules (PDF) (opens in a new tab)
- Prov: Arkansas electrical candidate information bulletin (2023.11.10, archived copy) (opens in a new tab)
Questions last verified November 13, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.