Requirements at a glance
| Agency | Arizona Registrar of Contractors (ROC); trade exam by PSI |
|---|---|
| Exams | 100 questions, 240 minutes, 70%, plus the online Statutes and Rules Exam (SRE) |
| Books allowed | 2018 IRC and 29 CFR 1926 |
| Fees | $66 PSI trade exam + $61 SRE, plus ROC license fees and bond |
Qualifying parties for an Arizona B General Residential Contractor (home builder), B-3 General Remodeling and Repair, or CR-61 Carpentry, Remodeling and Repairs license. One exam covers all three.
Official links
How to get licensed, step by step
Pick your classification and qualifying party
Find your classification on the ROC's list. The qualifying party (an owner or regular employee of the business) must have the required trade experience and takes the exams for the business.
Pass the Statutes and Rules Exam (SRE)
Buy the ROC's online SRE course and exam through GMetrix ($61), work through the course, then take the final exam. 70% to pass, one attempt per purchase.
Buy the Statutes and Rules Exam (GMetrix) (opens in a new tab)
Schedule the B trade exam with PSI
Book online with PSI ($66, or $116 for two exams). Bring the allowed references, bound and tabbed. If you fail, wait 30 days to retake.
Schedule with PSI (Arizona contractors) (opens in a new tab)PSI content outline: B, B-3 and CR-61 (opens in a new tab)
Apply to the ROC
Submit your application with your passing score reports within two years of passing, plus the license bond, fees and business documents the ROC asks for.
How to prepare
- Bring the exact code editions on PSI's list. Arizona's trade exams use older editions (2017 NEC, 2018 I-codes); a newer book gives some wrong answers.
- Bind or spiral any printed references, and tab them with permanent tabs before exam day. Sticky notes are removed at check-in.
- Practice finding answers fast. On a 100-question, 4-hour exam you have 2.4 minutes per question, and some of that goes to unscored items.
- Sitework, concrete and carpentry are 51 of the 100 questions. Know IRC Chapter 4 foundations, Chapter 5 floors, Chapter 6 walls and Chapter 8 roof framing, plus quantity math for concrete and lumber.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 International Residential Code (IRC)Essential
Allowed in the exam room. Code questions are based only on this edition.
ICC store (opens in a new tab)Read free (opens in a new tab)
29 CFR 1926 (OSHA Construction Standards), sections on your reference list
Trenching, scaffolds, fall protection and ladders. Print just the listed sections.
Official reference list (as published by the testing agency)
- International Residential Code (IRC), 2018 (allowed in the exam room)
- 29 CFR Part 1926, OSHA Construction (allowed in the exam room)
- Pipe and Excavation Contracting, Roberts (not allowed in the room)
- Carpentry and Building Construction, Feirer (not allowed in the room)
- Gypsum Construction Handbook, 7th ed., USG (not allowed in the room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Sitework | 17 | |
| Concrete | 17 | |
| Masonry | 9 | |
| Metal Framing | 6 | |
| Carpentry | 17 | |
| Thermal and Moisture Protection | 12 | |
| Doors and Windows | 7 | |
| Finishes | 9 | |
| Safety | 6 |
Exam day details
- Administered by PSI Services for the Arizona Registrar of Contractors (ROC).
- Fee: $66 to PSI ($116 for two exams taken together). The ROC license application fee is separate.
- 100 scored questions in 240 minutes, 70% to pass.
- Open book: bring your own bound copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them during the exam.
- PSI adds 5 to 10 unscored trial questions, which count against your time.
- If you fail, wait 30 days to retake; after a third failure the wait is 90 days. Submit your ROC application within two years of passing.
- You also need Arizona's Statutes and Rules Exam (SRE), taken online through the ROC. The ROC can waive the trade exam if you were the qualifying party on a license in the same classification in the last five years.
Frequently asked questions
What's on the Arizona B General Residential Contractor exam?
100 questions: sitework 17, concrete 17, carpentry 17, thermal and moisture protection 12, masonry 9, finishes 9, doors and windows 7, metal framing 6 and safety 6.
Is the B exam the same as the B-3 and CR-61 exams?
Yes. PSI uses one trade exam for the B, B-3 and CR-61 classifications, so passing it lets you apply for any of them without another trade exam.
What books can I bring to the Arizona B exam?
The 2018 International Residential Code and 29 CFR 1926 (OSHA construction standards). The other references on PSI's list, such as Carpentry and Building Construction, can't be brought in.
Free questions with answers
Show all 10 free questions and answers
Under the 2018 IRC, where nothing on the lot prevents it, how much must finished grade fall away from a foundation wall within the first 10 feet?
Answer: 6 inches
Section R401.3 requires lots to be graded so surface water drains away from foundation walls, with the grade falling at least 6 inches within the first 10 feet. That works out to about 5 percent. The 2 percent figure in the same section is for impervious surfaces such as walks and drives, not for soil grade. Where lot lines or walls make the 6-inch fall impossible, the exception allows drains or swales instead.
Reference: 2018 International Residential Code, Section R401.3
On a graded lot, a house's surface drainage discharges to a street gutter inlet 60 feet from the foundation. Using the IRC's prescriptive foundation-elevation rule, how far above the gutter inlet must the top of the exterior foundation be, at minimum?
Answer: 26.4 inches
Section R403.1.7.3 requires the top of the exterior foundation to be at least 12 inches plus 2 percent above the elevation of the street gutter at the point of discharge. The 2 percent is taken over the 60-ft distance: 60 ft x 12 in/ft = 720 in, and 720 x 0.02 = 14.4 in. Then 12 + 14.4 = 26.4 in. Answering 12.0 in leaves out the 2 percent. 13.2 in comes from taking 2 percent of 60 inches instead of 60 feet.
Reference: 2018 International Residential Code, Section R403.1.7.3
What is the minimum thickness of a concrete slab-on-ground floor under the 2018 IRC prescriptive provisions?
Answer: 3-1/2 inches
Section R506.1 requires slab-on-ground floors to be at least 3-1/2 inches thick (expansive soils are covered separately in R403.1.8). Many builders pour 4 inches as a matter of practice, but the code minimum is 3-1/2 inches. 4 inches is the base-course thickness required by R506.2.2.
Reference: 2018 International Residential Code, Section R506.1
A garage slab measures 24 feet by 36 feet and will be poured 4 inches thick. How many cubic yards of concrete does it need, before waste?
Answer: 10.7 cubic yards
Volume = 24 ft x 36 ft x (4/12) ft = 288 cubic feet. 288 / 27 = 10.67, or about 10.7 cubic yards. 128 comes from leaving the thickness in inches (24 x 36 x 4 / 27). 32.0 comes from dividing by 9 instead of 27. 9.3 assumes the 3-1/2-inch code minimum (R506.1) instead of the specified 4 inches.
Reference: General trade practice (concrete estimating), Slab volume: L x W x T (ft) / 27 = cubic yards; slab thickness per IRC R506.1
A 60-foot-long, 8-foot-high wall will be built of standard 8 x 8 x 16-inch concrete block (nominal face 8 in x 16 in). Ignoring openings and waste, about how many blocks are needed?
Answer: 540
Wall area = 60 x 8 = 480 sq ft. A nominal block face is 8 in x 16 in = 128 sq in = 0.889 sq ft, so it takes 144 / 128 = 1.125 blocks per square foot. 480 x 1.125 = 540 blocks. 480 assumes one block per square foot. 594 adds 10 percent waste, which the question excludes. 720 uses 1.5 blocks per square foot.
Reference: General trade practice (masonry estimating), Block count: wall area x 1.125 units per sq ft (8 x 16 nominal face); joints per IRC R606.3.1
A plumber needs to notch the top edge of a 2x10 sawn-lumber floor joist (actual depth 9-1/4 in) near the end third of the span, away from the support. What is the maximum notch depth?
Answer: About 1-1/2 inches
Section R502.8.1 limits notches in solid-lumber joists to one-sixth of the member depth, and they may not fall in the middle one-third of the span. 9.25 / 6 = 1.54 in, or about 1-1/2 in. 2-5/16 in (9.25 / 4) is the larger limit allowed only for notches at the ends of the member. 3-1/16 in is one-third of the depth, which is the limit for bored holes, not notches.
Reference: 2018 International Residential Code, Section R502.8.1
A stairway has a total rise of 105 inches between finished floors. Using the IRC maximum riser height, what is the minimum number of risers, and how tall is each one?
Answer: 14 risers at 7.50 inches
Section R311.7.5.1 limits risers to 7-3/4 in. 105 / 7.75 = 13.55, which rounds up to 14 risers, and 105 / 14 = 7.50 in each. 13 risers would be 8.08 in, over the limit. 15 risers would work but is more than the minimum. 14 risers at 7.75 in would total 108.5 in, not the actual 105-in rise.
Reference: 2018 International Residential Code, Section R311.7.5.1
An enclosed attic over a 1,500-sq-ft ceiling is vented with no reduction for vent placement. What minimum net free ventilating area does the IRC require?
Answer: 10 square feet
Section R806.2 sets the minimum net free ventilating area at 1/150 of the vented space: 1,500 / 150 = 10 sq ft. 5 sq ft (1/300) is allowed only under the exception, which requires 40 to 50 percent of the vent area high in the attic (plus a vapor retarder in Climate Zones 6 to 8). Remember to use the vents' net free area, not their gross size.
Reference: 2018 International Residential Code, Section R806.2
A second-floor bedroom window serves as the emergency escape and rescue opening. What does the IRC require for net clear opening area, height and width?
Answer: 5.7 sq ft; 24 in high; 20 in wide
Section R310.2.1 requires a net clear opening of at least 5.7 sq ft, with net clear height of at least 24 inches and net clear width of at least 20 inches, reached by normal operation from inside. 5.0 sq ft is allowed only for grade-floor or below-grade openings. The third choice swaps the height and width minimums.
Reference: 2018 International Residential Code, Section R310.2.1
Framers are setting roof trusses on a new house. At what height above a lower level does OSHA require guardrails, safety nets or personal fall arrest for residential construction work?
Answer: 6 feet
29 CFR 1926.501(b)(13) requires each employee in residential construction who is 6 feet or more above lower levels to be protected by guardrails, safety nets or personal fall arrest, unless another paragraph allows an alternative. Where the employer can show these are infeasible or create a greater hazard, a written site-specific fall protection plan under 1926.502(k) is required. 10 feet is the scaffold trigger in 1926.451(g)(1).
Reference: 29 CFR Part 1926 (OSHA Construction), 1926.501(b)(13)
Sources
- PSI: B, B-3 and CR-61 content outline (PDF) (opens in a new tab)
- PSI: Arizona ROC Candidate Information Bulletin (Feb 2026) (opens in a new tab)
- Arizona ROC: Applying for a license (opens in a new tab)
Questions last verified October 19, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.