Requirements at a glance
| Agency | Alaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI |
|---|---|
| Experience | Set by 12 AAC 32 (electrical) and 12 AAC 39 (mechanical); for the unlimited categories, for example 4 of the last 6 years as a journeyman plus management experience, or an equivalent |
| Exam | 100 questions, 4 hours, 70% |
| Books allowed | IMC 2012, Control Systems for HVAC (6th edition) and the Alaska mechanical statutes and regulations |
| Fee | $150 to PSI per registration, plus the CBPL application and license fees |
Refrigeration contractors seeking a mechanical administrator license in the unlimited refrigeration category from the Alaska CBPL.
Official links
How to get licensed, step by step
Apply to the CBPL
Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
Schedule the unlimited refrigeration exam with PSI
Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.
Schedule with PSI (mechanical administrators) (opens in a new tab)
Pass the exam
You need 70%. Scores are valid for 12 months toward the license.
Schedule with PSI (mechanical administrators) (opens in a new tab)
Get licensed
Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
- Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
- Component knowledge (21), testing and troubleshooting (15) and piping and tubing (14) are over half of the exam; the IMC covers refrigeration in Chapter 11.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Official reference list (as published by the testing agency)
- International Mechanical Code (IMC), 2012 edition
- Control Systems for Heating, Ventilating, and Air Conditioning, 6th edition
- Alaska Mechanical Administrator Statutes and Regulations (AS 08.40; 12 AAC 39)
- Alaska Centralized Regulations and Statutes
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Component Knowledge | 21 | |
| Testing and Troubleshooting | 15 | |
| Piping and Tubing | 14 | |
| Commercial Refrigeration Systems | 14 | |
| AK Statutes | 11 | |
| Controls | 10 | |
| Refrigerants | 8 | |
| Sizing | 7 |
Exam day details
- Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
- Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
- 100 scored questions in 4 hours; 70 correct (70%) to pass. Plus up to 10 unscored experimental items.
- Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
- PSI may add 1 to 10 unscored experimental items, which count against your time.
- The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
- Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.
Frequently asked questions
What is on the Alaska refrigeration administrator exam?
100 questions: component knowledge 21, testing and troubleshooting 15, piping and tubing 14, commercial refrigeration systems 14, Alaska statutes 11, controls 10, refrigerants 8 and sizing 7.
Which code book is allowed?
The 2012 IMC, along with the Alaska statutes and regulations and Control Systems for HVAC (6th edition) listed in the bulletin.
Free questions with answers
Show all 10 free questions and answers
Where is the sensing bulb of an externally equalized TXV normally attached?
Answer: To a clean section of suction line near the evaporator outlet, upstream of any suction-line heat exchanger or accumulator
The bulb must read the temperature of the vapor leaving the coil so that the valve can hold superheat. It is clamped tightly to a clean suction-line section close to the outlet, before any component that would change the gas temperature. A bulb on the liquid line or distributor would not measure superheat.
Reference: General practice (refrigeration), Metering devices: TXV bulb location
With the system running at normal load, a technician sees a steady stream of bubbles in the liquid-line sight glass at the receiver outlet. What does that most often indicate?
Answer: The liquid is flashing to vapor because of a low charge or a restriction ahead of the glass
A clear glass means solid liquid. Continuous bubbles show vapor in the liquid line, caused by too little charge, or a pressure drop (plugged drier, kinked line, vertical lift) that flashes liquid. Overcharge gives a clear glass, and moisture shows only as an indicator color change.
Reference: General practice (refrigeration), Liquid-line accessories: sight glass
A field-erected system uses ammonia (R-717). Which test gas may be used for the field test under Section 1108.2 that is not allowed for other refrigerants, as long as the system is evacuated before charging?
Answer: Air
Section 1108.2 requires an inert dried gas such as nitrogen or carbon dioxide and prohibits oxygen, air, combustible gases and mixtures containing them. The exception allows air on ammonia systems provided they are evacuated before charging with refrigerant.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1108.2
What must the apparatus used to build up the field test pressure include under Section 1108.3?
Answer: A pressure-limiting or pressure-reducing device and a gauge on the outlet side
Section 1108.3 says that the means used to raise test pressure must have either a pressure-limiting device or a pressure-reducing device and a gauge on the outlet side. This keeps a full nitrogen cylinder from over-pressurizing the system.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1108.3
Refrigerant piping has to be run in a concrete floor slab. What does Section 1107.2.1 require?
Answer: The piping is encased in pipe ducts, isolated and supported to prevent damaging vibration, stress and corrosion
Section 1107.2.1 requires refrigerant piping in concrete floors to be encased in pipe ducts, and isolated and supported so vibration, stress and corrosion do not damage it. Direct embedment is not allowed.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1107.2.1
An air-cooled condensing unit is on grade 12 feet from an operable door of a restaurant. Under Section 1103.2, which occupancy classification governs the unit?
Answer: The classification of the restaurant (public assembly) building
Section 1103.2 says equipment other than piping that is located outside a building and within 20 feet of any building opening is governed by the building's occupancy classification. Restaurants are listed under public assembly.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1103.2
Which work falls within the scope of an unlimited refrigeration administrator license under 12 AAC 39.272(a)?
Answer: Supervising installation of cooling tower, condensing water and chilled water piping for a refrigeration system
12 AAC 39.272(a) covers refrigeration and air conditioning systems unlimited as to capacity or refrigerant, including domestic water piping from an existing valved connection to the system, tower and condensing water piping, and chilled water piping. Work is limited to the refrigerant cycle, controls and related appurtenances.
Reference: Alaska Mechanical Administrator Statutes and Regulations, 12 AAC 39.272(a)
Which problem is a phase monitor relay on a three-phase compressor designed to guard against?
Answer: Loss of a phase, phase reversal or a serious voltage unbalance
A phase monitor opens the control circuit on single-phasing, reversed rotation or serious unbalance. Reversed rotation can ruin a scroll compressor in seconds and single-phasing overheats the motor. Pressure and oil problems are handled by pressure and oil safeties.
Reference: General practice (refrigeration), Controls: phase monitor
A rack running R-404A is low on charge. The technician has only R-507A on the truck and proposes to top off the system. What does Section 1102.2.1 say about this?
Answer: It is not allowed, because refrigerants with different ASHRAE 34 designations may not be mixed
Section 1102.2.1 prohibits mixing refrigerants or blends with different ASHRAE 34 designations in a system. The only exception is adding a second refrigerant where the equipment manufacturer permits it to improve oil return at low temperatures, in the manufacturer's stated amount.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1102.2.1
Section 1105.6.3.1 sets an area-based normal ventilation rate for a refrigeration machinery room that is not an ammonia room. What is that rate for a machinery room 24 ft by 18 ft?
Answer: 216 cfm
Section 1105.6.3.1 gives 0.5 cfm per square foot of machinery room area (or 20 cfm per person) as the baseline, with a larger rate where needed to limit room temperature rise to 18 degrees F. Area: 24 x 18 = 432 sq ft; 432 x 0.5 = 216 cfm. 432 uses 1 cfm per sq ft, 60 is three persons at 20 cfm, and 8,640 multiplies by 20.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1105.6.3.1
Sources
- PSI: Alaska Mechanical Administrators Examination Candidate Information Bulletin (updated 10/15/2026) (opens in a new tab)
- Alaska Division of Corporations, Business and Professional Licensing (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.