Alaska Mechanical Systems Temperature Control Administrator Exam: Practice Test & Licensing Guide

The PSI exam for Alaska's mechanical systems temperature control administrator license: 60 questions on electricity, HVAC unit controls, pneumatics, piping and testing. Open book.

Questions
60
Time limit
2 hours
Passing score
70%
Books
Open book

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10AK Statutes

Under 12 AAC 39.292, a mechanical administrator in the mechanical systems temperature control category may supervise the retrofitting of control wiring up to what voltage?

Requirements at a glance

AgencyAlaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI
ExperienceSet by 12 AAC 39.292 for the mechanical systems temperature control category
Exam60 questions, 2 hours, 70%
Books allowedIMC 2012, NEC 2014 (or the NEC Handbook), NFPA 54 (2018) and the Alaska mechanical statutes and regulations
Fee$150 to PSI per registration, plus the CBPL application and license fees

Controls technicians and contractors seeking a mechanical administrator license in the mechanical systems temperature control category.

How to get licensed, step by step

  1. Apply to the CBPL

    Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.

    Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)

  2. Schedule the temperature control exam with PSI

    Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.

    Schedule with PSI (mechanical administrators) (opens in a new tab)

  3. Pass the exam

    You need 70%. Scores are valid for 12 months toward the license.

    Schedule with PSI (mechanical administrators) (opens in a new tab)

  4. Get licensed

    Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.

    Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
  • Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
  • Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
  • Electricity and electronics and Alaska statutes are 12 questions each. Control Systems for HVAC is not allowed in the room for this exam.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

    Official reference list (as published by the testing agency)
    • International Mechanical Code (IMC), 2012 edition
    • NFPA 70 National Electrical Code, 2014 edition, or the NEC Handbook (as the bulletin lists)
    • NFPA 54 National Fuel Gas Code, 2018 edition
    • Alaska Mechanical Administrator Statutes and Regulations (AS 08.40; 12 AAC 39)
    • Alaska Centralized Regulations and Statutes

    What's on the exam

    Official content outline from PSI Services (number of questions per topic):

    TopicQuestions
    Electricity and Electronics12
    AK Statutes12
    HVAC Unit Controls8
    Pneumatics6
    Terminology5
    Piping and Tubing5
    Sizing and Estimating6
    Testing and Inspecting6

    Exam day details

    • Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
    • Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
    • 60 scored questions in 2 hours; 42 correct (70%) to pass. Plus up to 10 unscored experimental items.
    • Control Systems for HVAC (6th edition), listed for other mechanical exams, is not allowed in the room for this one.
    • Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
    • PSI may add 1 to 10 unscored experimental items, which count against your time.
    • The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
    • Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.

    Frequently asked questions

    What is on the Alaska temperature control exam?

    60 questions: electricity and electronics 12, Alaska statutes 12, HVAC unit controls 8, pneumatics 6, sizing and estimating 6, testing and inspecting 6, terminology 5 and piping and tubing 5.

    Which NEC edition does this exam list?

    The PSI bulletin lists the 2014 NEC or the NEC Handbook for this exam, unlike the 2020 NEC on the electrical exams.

    Free questions with answers

    Show all 10 free questions and answers
    1. Under 12 AAC 39.292, a mechanical administrator in the mechanical systems temperature control category may supervise the retrofitting of control wiring up to what voltage?

      Answer: 48 volts or less

      12 AAC 39.292 allows the temperature control administrator to supervise installation or retrofitting of all pneumatic or electric controls and the retrofitting of control wiring of 48 volts or less, as long as the work does not alter the electrical characteristics of the mechanical system. Line-voltage work is outside that scope.

      Reference: Alaska Mechanical Administrator Statutes and Regulations, 12 AAC 39.292

    2. A mechanical administrator changes employers. Within how many days must the department be notified in writing under 12 AAC 39.912?

      Answer: 15 days after the change

      12 AAC 39.912 requires written notice within 15 days after a change in employment or company affiliation, with the change fee and a notarized statement naming the old and new companies, dates, contractor license numbers and the administrator's license number.

      Reference: Alaska Mechanical Administrator Statutes and Regulations, 12 AAC 39.912

    3. Two loads of 30 ohms and 60 ohms are wired in parallel across the same supply. What is the combined resistance?

      Answer: 20 ohms

      For two parallel resistances, R = (R1 x R2) / (R1 + R2) = (30 x 60) / 90 = 20 ohms. Combined resistance in parallel is always less than the smallest branch. Averaging (45) or adding (90) is wrong, and 1,800 is only the product.

      Reference: General practice (HVAC controls), Parallel circuit resistance

    4. A 120-volt primary, 24-volt secondary control transformer is rated 50 VA. What is the maximum secondary current?

      Answer: 2.08 amps

      Secondary current = VA / secondary volts = 50 / 24 = 2.08 A. The 0.42 A answer is the primary current (50 / 120), 26 comes from subtracting the voltage from the VA rating, and 1,200 comes from multiplying VA by volts; neither is a current.

      Reference: General practice (HVAC controls), Transformer rating, I = VA / E

    5. Under IMC 1006.8, which side of a boiler control circuit must the control and limit devices interrupt?

      Answer: The ungrounded side of the circuit

      IMC 1006.8 requires control and limit devices to interrupt the ungrounded side of the circuit, so a fault to ground cannot bypass a limit. The grounded conductor is not switched.

      Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1006.8

    6. A pneumatic temperature transmitter has a 0 to 200 degree F range and a 3 to 15 psig output. The output is 12 psig. What temperature is being measured?

      Answer: 150 degrees F

      Span of output = 15 - 3 = 12 psi. Fraction = (12 - 3) / 12 = 0.75. Temperature = 0.75 x 200 = 150 F. Using 12 / 15 gives 160, which ignores the 3 psig live zero, and 0.6 x 200 = 120 treats 12 psig as 60 percent.

      Reference: General practice (HVAC controls), Pneumatic transmitter scaling

    7. A direct-acting controller is used. What happens to its output signal as the measured temperature rises?

      Answer: The output signal increases

      A direct-acting (DA) controller's output rises as the controlled variable rises; a reverse-acting (RA) controller's output falls as the variable rises. Whether DA or RA is chosen depends on the action of the controlled device (for example a normally open or normally closed valve).

      Reference: General practice (HVAC controls), Control terminology: direct and reverse acting

    8. A glycol hydronic system has a maximum operating temperature of 180 degrees F. Under IMC 1207.1, what is the minimum flash point of the transfer fluid?

      Answer: 230 degrees F

      IMC 1207.1 requires the flash point of the transfer fluid to be at least 50 F above the maximum system operating temperature: 180 + 50 = 230 F. Subtracting gives 130, and 180 would be no margin at all.

      Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1207.1

    9. A zone requires 2,000 cfm of supply air at a 20 degree F temperature difference. What sensible load does that airflow carry? Use Q = 1.08 x cfm x TD.

      Answer: 43,200 Btu/h

      Q = 1.08 x 2,000 x 20 = 43,200 Btu/h. Omitting the 1.08 factor gives 40,000, omitting the temperature difference gives 2,160, and using the 4.5 mass-flow factor for lb/h of air gives 180,000.

      Reference: General practice (HVAC controls), Sensible heat equation for air

    10. With the power off and the coil leads disconnected, an ohmmeter reads infinite resistance across a contactor coil. What does this indicate?

      Answer: The coil winding is open and the coil must be replaced

      A good coil shows some resistance, typically tens or hundreds of ohms. An infinite reading means an open winding, so the coil cannot pull in. A shorted coil reads a much lower resistance than normal.

      Reference: General practice (HVAC controls), Troubleshooting with an ohmmeter