Requirements at a glance
| Agency | Alaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI |
|---|---|
| Experience | Set by 12 AAC 32 (electrical) and 12 AAC 39 (mechanical); for the unlimited categories, for example 4 of the last 6 years as a journeyman plus management experience, or an equivalent |
| Exam | 100 questions, 4 hours, 70% |
| Books allowed | IMC 2012, NFPA 54 (2018), Control Systems for HVAC (6th edition) and the Alaska mechanical statutes and regulations |
| Fee | $150 to PSI per registration, plus the CBPL application and license fees |
HVAC and sheet metal contractors seeking a mechanical administrator license in the unlimited HVAC and sheet metal category from the Alaska CBPL.
Official links
How to get licensed, step by step
Apply to the CBPL
Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
Schedule the unlimited HVAC exam with PSI
Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.
Schedule with PSI (mechanical administrators) (opens in a new tab)
Pass the exam
You need 70%. Scores are valid for 12 months toward the license.
Schedule with PSI (mechanical administrators) (opens in a new tab)
Get licensed
Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
- Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
- Boilers and burners, chimneys, flues and vents, and fuel piping are 15 questions each: tab IMC Chapters 8 and 10 and the NFPA 54 sizing and venting chapters.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Official reference list (as published by the testing agency)
- International Mechanical Code (IMC), 2012 edition
- NFPA 54 National Fuel Gas Code, 2018 edition
- Control Systems for Heating, Ventilating, and Air Conditioning, 6th edition
- Alaska Mechanical Administrator Statutes and Regulations (AS 08.40; 12 AAC 39)
- Alaska Centralized Regulations and Statutes
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Boilers and Burners | 15 | |
| Chimneys, Flues, Vents | 15 | |
| Fuel Piping and Storage | 15 | |
| Controls and Electrical | 10 | |
| Duct Systems and Sheet Metal | 10 | |
| AK Statutes | 10 | |
| Steam and Hot Water Piping | 5 | |
| Air Conditioning | 5 | |
| Refrigeration Piping | 4 | |
| Chillers | 4 | |
| Pneumatics | 3 | |
| Evaporative Cooling | 1 | |
| Heat Pumps | 3 |
Exam day details
- Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
- Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
- 100 scored questions in 4 hours; 70 correct (70%) to pass. Plus up to 10 unscored experimental items.
- Experience (12 AAC 39): for example 4 of the last 6 years as a journeyman plus management experience, or an equivalent. Check the Division's current rules.
- Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
- PSI may add 1 to 10 unscored experimental items, which count against your time.
- The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
- Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.
Frequently asked questions
What is on the Alaska unlimited HVAC exam?
100 questions: boilers and burners 15, chimneys, flues and vents 15, fuel piping and storage 15, controls and electrical 10, duct systems and sheet metal 10, Alaska statutes 10, steam and hot water piping 5, air conditioning 5, refrigeration piping 4, chillers 4, pneumatics 3, heat pumps 3 and evaporative cooling 1.
Which code editions are used?
The 2012 IMC and the 2018 NFPA 54.
Free questions with answers
Show all 10 free questions and answers
A hot water heating boiler with no manhole on top has an input of 3,000,000 Btu/h. What is the minimum clearance from the top of the boiler to the ceiling under Table 1004.3.1?
Answer: 2 feet
Table 1004.3.1 sets 2 feet for boilers without a top manhole (other than high-pressure steam boilers). The 3-foot figure applies to boilers with a manhole, or to hot water boilers whose input exceeds 5,000,000 Btu/h; 3,000,000 Btu/h is below that threshold. 7 feet is for the largest high-pressure steam boilers.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), Table 1004.3.1
What is the maximum horizontal length of a single-wall vent connector under Section 803.10.2?
Answer: 75 percent of the height of the chimney or vent
Section 803.10.2 limits a single-wall connector's horizontal run to 75 percent of the chimney or vent height. A 20-foot vent therefore allows at most 15 feet of horizontal single-wall connector.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 803.10.2
What are the minimum sizes of the fuel oil return line, and which wall thickness must copper tubing have, under Section 1305.1?
Answer: 1/4-inch ID pipe or 5/16-inch OD tubing; copper tubing 0.035-inch nominal and 0.032-inch minimum wall
Section 1305.1 gives return line minimums of 1/4-inch ID nominal pipe or 5/16-inch OD tubing, and says copper tubing shall have 0.035-inch nominal and 0.032-inch minimum wall thickness. The 3/8-inch size is the supply line minimum.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1305.1
Under AS 08.40.260(b), a person licensed as a mechanical administrator may perform work in which categories?
Answer: Only the category for which the person is licensed
AS 08.40.260(b) limits a licensed administrator to work in the category for which the person is licensed. Adding a category requires a further application under 12 AAC 39.025.
Reference: Alaska Mechanical Administrator Statutes and Regulations, AS 08.40.260(b)
Using Table 603.4 for ducts within a single dwelling unit, what is the minimum galvanized sheet thickness for a 16-inch round duct?
Answer: 0.0187 inch (No. 26 gage)
Table 603.4 lists 0.0157 inch (28 gage) for round and enclosed rectangular ducts of 14 inches or less, 0.0187 inch (26 gage) for 16 and 18 inches, and 0.0236 inch (24 gage) for 20 inches and over. The 0.0175 figure is an aluminum thickness, not galvanized.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), Table 603.4
A cooling coil has no secondary drain and no provision for an auxiliary pan, such as a downflow unit. What does Section 307.2.3.1 require?
Answer: A water-level monitoring device inside the primary drain pan, shutting off the equipment
Section 307.2.3.1 requires a water-level monitoring device inside the primary drain pan to shut off the equipment if the primary drain becomes restricted, and does not permit devices installed in the drain line. Section 307.2.3 refers to devices conforming to UL 508.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 307.2.3.1
What is the minimum hydrostatic test pressure and duration for a hot water heating piping system with a design pressure of 40 psi, under Section 1208.1?
Answer: 100 psi for at least 15 minutes
Section 1208.1 requires hydrostatic testing at 1.5 times maximum system design pressure but not less than 100 psi, held at least 15 minutes. 1.5 x 40 = 60 psi, which is below the 100 psi floor, so 100 psi governs.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1208.1
Several air handlers totaling 60 tons of refrigeration are manifolded into one condensate drain. What minimum pipe diameter does Table 307.2.2 require?
Answer: 1-1/4 inch
Table 307.2.2 lists 3/4 inch up to 20 tons, 1 inch over 20 to 40 tons, 1-1/4 inch over 40 to 90 tons, 1-1/2 inch over 90 to 125 tons and 2 inch over 125 to 250 tons. At 60 tons the equipment falls in the over 40 to 90 ton row.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), Table 307.2.2
Refrigerant piping crosses an open space that serves as a passageway in a building. What minimum height above the floor applies under Section 1107.2?
Answer: 7 feet 3 inches, unless the piping is against the ceiling
Section 1107.2 says refrigerant piping crossing an open space that affords passageway must be not less than 7 feet 3 inches above the floor unless it is located against the ceiling of that space. It may not be in elevator shafts, shafts with openings to living quarters or means of egress, or in enclosed public stairways.
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1107.2
What minimum normal ventilation rate must a machinery room (other than ammonia) provide while occupied, per Section 1105.6.3.1?
Answer: The larger of 0.5 cfm per square foot of room or 20 cfm per person, or the flow limiting temperature rise to 18 degrees F
Section 1105.6.3.1 requires exhaust of the larger of: not less than 0.5 cfm per square foot of machinery room area or 20 cfm per person; or the volume needed to limit room temperature rise to 18 F considering heat from machinery. The 30 air changes per hour value applies to ammonia (1105.6.3).
Reference: 2012 International Mechanical Code (Alaska Mechanical Code 2012), 1105.6.3 and 1105.6.3.1
Sources
- PSI: Alaska Mechanical Administrators Examination Candidate Information Bulletin (updated 10/15/2026) (opens in a new tab)
- Alaska Division of Corporations, Business and Professional Licensing (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.