Requirements at a glance
| Agency | Alaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI |
|---|---|
| Experience | Set by 12 AAC 32 (electrical) and 12 AAC 39 (mechanical); for the unlimited categories, for example 4 of the last 6 years as a journeyman plus management experience, or an equivalent |
| Exam | 100 questions, 4 hours, 70% |
| Books allowed | 2020 NEC and NFPA 72 (2013), plus the Alaska electrical statutes and regulations |
| Fee | $150 to PSI per registration, plus the CBPL application and license fees |
Electricians seeking an electrical administrator license in the unlimited commercial wiring category from the Alaska CBPL. An electrical contractor must employ a licensed administrator.
Official links
How to get licensed, step by step
Apply to the CBPL
Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
Schedule the unlimited commercial wiring exam with PSI
Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.
Schedule with PSI (electrical administrators) (opens in a new tab)
Pass the exam
You need 70%. Scores are valid for 12 months toward the license.
Schedule with PSI (electrical administrators) (opens in a new tab)
Get licensed
Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
- Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
- Grounding and bonding, services and feeders, raceways and conductors are 52 of the 100 questions: tab Articles 250, 210, 215, 230, 300 to 320 and 310.
- Fire alarm and low-voltage items come from NFPA 72 (2013) and NEC Articles 725 and 760.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Official reference list (as published by the testing agency)
- National Electrical Code (NFPA 70), 2020 edition
- NFPA 72 National Fire Alarm and Signaling Code, 2013 edition
- Alaska Electrical Administrator Statutes and Regulations (AS 08.40; 12 AAC 32)
- Alaska Centralized Regulations and Statutes
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 9 | |
| Grounding and Bonding | 13 | |
| Services, Feeders, Branch Circuits | 13 | |
| Raceways and Enclosures | 13 | |
| Conductors and Cables | 13 | |
| Special Occupancies | 8 | |
| Electrical Power | 3 | |
| Motors | 5 | |
| Low Voltage | 4 | |
| Lighting | 3 | |
| Photovoltaics | 3 | |
| Alarm Systems | 3 | |
| Safety | 5 | |
| Alaska Statutes and Regulations | 5 |
Exam day details
- Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
- Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
- 100 scored questions in 4 hours; 70 correct (70%) to pass. Plus up to 10 unscored experimental items.
- Experience (12 AAC 32): for example 4 of the last 6 years as a journeyman plus management experience, or an equivalent. Check the Division's current rules.
- The administrator license covers inside wiring, inside communications and controls work; it excludes linework.
- Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
- PSI may add 1 to 10 unscored experimental items, which count against your time.
- The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
- Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.
Frequently asked questions
What is on the Alaska unlimited commercial wiring exam?
100 questions: grounding and bonding 13, services, feeders and branch circuits 13, raceways and enclosures 13, conductors and cables 13, general electrical knowledge 9, special occupancies 8, motors 5, safety 5, Alaska statutes and regulations 5, low voltage 4, and 3 each for electrical power, lighting, photovoltaics and alarm systems.
Which NEC edition does Alaska test?
The 2020 NEC. Code questions are based only on the edition the bulletin lists.
Can I retake the exam?
Yes. Your eligibility letter is valid for one year and you may test as many times as you like in that year, paying the fee each time.
Free questions with answers
Show all 10 free questions and answers
A 480Y/277-volt switchboard in a commercial electrical room has exposed live parts on its front. Another switchboard with exposed live parts faces it across the aisle. Using Table 110.26(A)(1), what is the minimum depth of working space in front of the first switchboard?
Answer: 4 ft (1.2 m), because live parts are exposed on both sides of the working space
Table 110.26(A)(1) is entered with the nominal voltage to ground (277 V, which falls in the 151-600 V row). Condition 1 is 3 ft, Condition 2 (live parts on one side, grounded parts on the other) is 3 ft 6 in., and Condition 3 (live parts on both sides) is 4 ft. Two facing switchboards with exposed live parts are Condition 3.
Reference: 2020 National Electrical Code (NFPA 70), Table 110.26(A)(1)
A 500 kcmil copper service-entrance conductor set has a grounding electrode conductor that connects only to a single driven ground rod. Under 250.66(A), what is the largest copper conductor size that is required for that connection?
Answer: 6 AWG copper
Where the grounding electrode conductor goes to a rod, pipe or plate electrode only, it is not required to be larger than 6 AWG copper, no matter how large the service conductors are. Table 250.66 would give 1/0 AWG for 500 kcmil, but 250.66(A) caps the requirement at 6 AWG.
Reference: 2020 National Electrical Code (NFPA 70), 250.66(A)
A rooftop air-conditioning unit is installed on a commercial building roof. What does Section 210.63 require regarding a receptacle outlet for servicing?
Answer: A 125-volt, 15- or 20-ampere receptacle on the same level within 25 ft
Section 210.63 requires a 125-volt, 15- or 20-ampere receptacle outlet at an accessible location for the servicing of heating, air-conditioning and refrigeration equipment on rooftops, in attics and in crawl spaces. It must be on the same level and within 25 ft of the equipment, and may not be connected to the load side of the equipment's disconnecting means.
Reference: 2020 National Electrical Code (NFPA 70), 210.63
A run of EMT between two pull boxes already contains three 90-degree bends. What additional bending may be added without exceeding the Code limit between pull points?
Answer: One more 90-degree bend, for a total of 360 degrees
There may not be more than the equivalent of four quarter bends, a total of 360 degrees, between pull points such as conduit bodies and boxes. Three 90-degree bends use 270 degrees, which leaves room for exactly one more 90-degree bend.
Reference: 2020 National Electrical Code (NFPA 70), 358.26
A 3-phase, 4-wire, 208Y/120-volt feeder serves a large number of computers and electronic ballasts. Four conductors (three phases and a neutral) are in one conduit. How are the current-carrying conductors counted for the adjustment factor?
Answer: All four are counted, because the neutral carries harmonic current
On a 4-wire 3-phase wye circuit where the major portion of the load is nonlinear (computers, electronic ballasts), harmonic currents add on the neutral, so it is considered a current-carrying conductor. With four current-carrying conductors the 80 percent factor of Table 310.15(C)(1) applies.
Reference: 2020 National Electrical Code (NFPA 70), 310.15(E)(3)
Which description matches a Class I, Division 1 location?
Answer: Ignitable concentrations of flammable gas or vapor exist under normal operating conditions
Class I locations involve flammable gases or vapors. In Division 1, ignitable concentrations exist under normal operating conditions, frequently because of repair, maintenance or leakage. Division 2 locations are those where the hazard exists only under abnormal conditions, and Classes II and III cover dusts and fibers.
Reference: 2020 National Electrical Code (NFPA 70), 500.5(B)(1)
A 10-hp, 230-volt, 3-phase squirrel-cage motor has a Table 430.250 full-load current of 28 amperes. Using 75 C copper conductors, what is the smallest branch-circuit conductor for continuous duty?
Answer: 10 AWG, since 28 x 1.25 = 35 A and 10 AWG carries 35 A
Motor branch-circuit conductors must have an ampacity of at least 125 percent of the table full-load current: 28 x 1.25 = 35 A. In the 75 C column of Table 310.16, 12 AWG is 25 A and 10 AWG is 35 A, so 10 AWG is the smallest. The nameplate current is not used for this sizing.
Reference: 2020 National Electrical Code (NFPA 70), 430.22(A); Table 430.250
What are the maximum voltage and power limits for a Class 1 power-limited circuit?
Answer: 30 volts and 1000 volt-amperes
Class 1 power-limited circuits are supplied by a source limited to 30 V and 1000 VA. Class 1 remote-control and signaling circuits can operate up to 600 V with no specific VA limit, and Class 2 sources are limited to much lower power.
Reference: 2020 National Electrical Code (NFPA 70), 725.41(A)
An unqualified person is working in an elevated position near unguarded overhead lines energized at 12 kV to ground. What is the minimum distance that the person and the longest conductive object they handle must remain from the lines?
Answer: 10 ft
For unqualified persons working near unguarded, energized overhead lines at voltages to ground of 50 kV or less, the minimum approach distance is 10 ft. For voltages above 50 kV, 4 in. is added for every 10 kV over 50 kV.
Reference: 29 CFR 1910 Subpart S (Electrical), 29 CFR 1910.333(c)(3)(i)(A)
Under 12 AAC 32.930, what does a year of experience mean for electrical administrator qualification?
Answer: Within 12 consecutive months, at least 1,500 hours worked in the required field or position
The regulation defines a year of experience as 12 consecutive months in which the applicant worked in a required field or position for at least 1,500 hours. Applicants' experience is counted in those blocks when they apply for the license.
Reference: Alaska Administrative Code, 12 AAC 32, 12 AAC 32.930
Sources
- PSI: Alaska Electrical Administrators Examination Candidate Information Bulletin (updated 10/15/2026) (opens in a new tab)
- Alaska Division of Corporations, Business and Professional Licensing (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.