Requirements at a glance
| Agency | Alaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI |
|---|---|
| Experience | Set by 12 AAC 32; the license covers dwellings up to three stories and no larger than a four-plex, without three-phase services |
| Exam | 75 questions, 3 hours, 70% |
| Books allowed | 2020 NEC and 29 CFR 1926, plus the Alaska electrical statutes and regulations |
| Fee | $150 to PSI per registration, plus the CBPL application and license fees |
Electricians seeking an electrical administrator license in the residential wiring category (dwellings up to three stories and no larger than a four-plex, no three-phase services).
Official links
How to get licensed, step by step
Apply to the CBPL
Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
Schedule the residential wiring exam with PSI
Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.
Schedule with PSI (electrical administrators) (opens in a new tab)
Pass the exam
You need 70%. Scores are valid for 12 months toward the license.
Schedule with PSI (electrical administrators) (opens in a new tab)
Get licensed
Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
- Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
- Grounding and bonding, raceways and conductors (10 each) lead the exam; add services and branch circuits (9).
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Official reference list (as published by the testing agency)
- National Electrical Code (NFPA 70), 2020 edition
- 29 CFR Part 1926 (OSHA construction standards)
- Alaska Electrical Administrator Statutes and Regulations (AS 08.40; 12 AAC 32)
- Alaska Centralized Regulations and Statutes
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General | 6 | |
| Grounding and Bonding | 10 | |
| Services/Feeders/Branch | 9 | |
| Raceways and Enclosures | 10 | |
| Conductors and Cables | 10 | |
| Special Equipment | 3 | |
| Lighting | 5 | |
| Low Voltage | 5 | |
| Photovoltaics | 3 | |
| Alarm Systems | 5 | |
| Safety | 4 | |
| AK Statutes and Regs | 5 |
Exam day details
- Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
- Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
- 75 scored questions in 3 hours; 53 correct (70%) to pass. Plus up to 10 unscored experimental items.
- Scope (12 AAC 32.165(b), .195(b), .275(b)): residential inside wiring, inside communications and controls on a dwelling unit not above three stories and no larger than a four-plex, excluding three-phase services and wiring.
- Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
- PSI may add 1 to 10 unscored experimental items, which count against your time.
- The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
- Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.
Frequently asked questions
What is on the Alaska residential wiring administrator exam?
75 questions: grounding and bonding 10, raceways and enclosures 10, conductors and cables 10, services, feeders and branch circuits 9, general 6, lighting 5, low voltage 5, alarm systems 5, Alaska statutes and regulations 5, safety 4, special equipment 3 and photovoltaics 3.
How long is the exam?
Three hours (180 minutes) for 75 questions, with 70% to pass.
Free questions with answers
Show all 10 free questions and answers
A residential wiring administrator reads an Informational Note under a 2020 NEC section. How should the note be treated?
Answer: As explanatory material that is not an enforceable requirement of the Code
Section 90.5(C) says explanatory material, including Informational Notes, is for information only and is not a requirement of the Code. A common example is the voltage-drop recommendation in the notes to 210.19(A).
Reference: 2020 National Electrical Code (NFPA 70), 90.5(C)
A dwelling has 2/0 AWG copper service-entrance conductors. The grounding electrode conductor runs to a metal underground water pipe. What is the smallest copper grounding electrode conductor permitted?
Answer: 4 AWG
Table 250.66 lists 4 AWG copper for service conductors of 2/0 or 3/0 AWG copper. The 6 AWG reduction applies only when the conductor goes solely to rod, pipe or plate electrodes, and a water-pipe connection does not get that reduction.
Reference: 2020 National Electrical Code (NFPA 70), Table 250.66
Optional dwelling method (220.82): a home has 2,400 sq ft, two small-appliance circuits, a laundry circuit, a 12,000 W range, a 5,500 W dryer, a 4,500 W water heater, a 1,200 W dishwasher and 4,000 VA of air conditioning. What is the calculated load?
Answer: 23,960 VA
General load: 2,400 x 3 = 7,200 + 3,000 + 1,500 + 12,000 + 5,500 + 4,500 + 1,200 = 34,900 VA. First 10,000 VA at 100% = 10,000; remaining 24,900 at 40% = 9,960; total 19,960. Add 100% of the A/C (4,000) for 23,960 VA. 19,960 leaves out the A/C and 38,900 skips the demand factor.
Reference: 2020 National Electrical Code (NFPA 70), 220.82(B) and (C)
What is the maximum spacing for securing a run of EMT, and how close must the first support be to each outlet box?
Answer: 10 feet between supports, with a support within 3 feet of each box
Section 358.30(A) requires EMT to be fastened at intervals not exceeding 10 ft and within 3 ft of each outlet box, junction box, device box, cabinet or fitting.
Reference: 2020 National Electrical Code (NFPA 70), 358.30(A)
Type NM-B cable has 10 AWG copper conductors with 90 C insulation, and no adjustment or correction factors apply. What ampacity may be used for the cable in the Code tables?
Answer: 30 amperes
Section 334.80 requires the ampacity of Type NM cable to be the 60 C column of Table 310.16, even though the conductors are rated 90 C. For 10 AWG copper the 60 C value is 30 A. The 90 C value of 40 A can be used only as the starting point for derating.
Reference: 2020 National Electrical Code (NFPA 70), 334.80 and Table 310.16
A recessed luminaire will be installed in an Alaskan insulated attic ceiling where insulation will contact the housing. What type of luminaire is required?
Answer: A luminaire marked as Type IC, rated for direct contact with insulation
Section 410.116 requires recessed luminaires that will contact thermal insulation to be Type IC. Non-IC luminaires must be kept at least 1/2 in from combustible material and insulation kept 3 in from the enclosure.
Reference: 2020 National Electrical Code (NFPA 70), 410.116
Class 2 thermostat cable is to be pulled into a conduit that already carries 120-volt lighting branch-circuit conductors. What does the 2020 NEC say?
Answer: It is not allowed unless a barrier or another 725.136 exception applies
Section 725.136 keeps Class 2 and Class 3 conductors out of the same cable, raceway or enclosure as light, power and Class 1 conductors unless separated by a barrier or one of the listed exceptions applies.
Reference: 2020 National Electrical Code (NFPA 70), 725.136(A)
A 16 AWG conductor is used in a non-power-limited fire alarm circuit. What is the maximum overcurrent protection for it?
Answer: 10 amperes
Section 760.43 limits overcurrent protection for non-power-limited fire alarm conductors to 7 A for 18 AWG and 10 A for 16 AWG; 14 AWG and larger are protected according to their ampacity without adjustment or correction factors. 7 A is the 18 AWG limit, and 15 A and 20 A are 14 AWG and 12 AWG branch-circuit values.
Reference: 2020 National Electrical Code (NFPA 70), 760.43
When a circuit is de-energized for work, how must it be handled under OSHA?
Answer: Rendered inoperative, with tags at every point where it could be energized
Section 1926.417 requires de-energized circuits to be made inoperative and tagged at all points where they could be energized, with tags identifying the equipment or circuit.
Reference: 29 CFR Part 1926, 1926.417(b)
Which project is within the scope of the residential wiring administrator license?
Answer: A three-story four-plex served by single-phase 120/240-volt services
12 AAC 32.235(a) limits the license to a dwelling unit not exceeding three stories and no larger than a four-plex, excluding three-phase services and wiring.
Reference: Alaska Electrical Administrator Statutes and Regulations (AS 08.40; 12 AAC 32), 12 AAC 32.235(a)
Sources
- PSI: Alaska Electrical Administrators Examination Candidate Information Bulletin (updated 10/15/2026) (opens in a new tab)
- Alaska Division of Corporations, Business and Professional Licensing (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.