Requirements at a glance
| Agency | Alaska Division of Corporations, Business and Professional Licensing (CBPL); exam by PSI |
|---|---|
| Experience | Set by 12 AAC 32 for the controls and control wiring category |
| Exam | 50 questions, 2 hours, 70% |
| Books allowed | 2020 NEC, NFPA 72 (2013), Control Systems for HVAC (6th edition) and the Alaska electrical statutes and regulations |
| Fee | $150 to PSI per registration, plus the CBPL application and license fees |
Electricians seeking an electrical administrator license in the controls and control wiring category (low-voltage controls of 48 volts or less for heating, cooling, ventilating and refrigerating equipment; no power wiring).
Official links
How to get licensed, step by step
Apply to the CBPL
Send the Division your application, fee and supporting documents. When it approves you, it mails an eligibility letter with your state ID number.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
Schedule the controls and control wiring exam with PSI
Register online or call PSI at 855-746-8173. Your eligibility letter is valid for one year and you can retake as often as you like in that year, paying each time.
Schedule with PSI (electrical administrators) (opens in a new tab)
Pass the exam
You need 70%. Scores are valid for 12 months toward the license.
Schedule with PSI (electrical administrators) (opens in a new tab)
Get licensed
Send the Division your results and the license fee. Administrator licenses run 2 years and expire December 31 of odd-numbered years.
Alaska Division of Corporations, Business and Professional Licensing (CBPL) (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline: the 2020 NEC, 2018 UPC, 2012 IMC, 2018 NFPA 54 and 2018 IRC. Code questions are based only on the listed edition.
- Tab your books before exam day with permanent tabs only. You can highlight and underline, but you can't write in them or bring loose papers; sticky notes are removed.
- Every administrator exam has an Alaska statutes and regulations section drawn from the Division's PDFs (AS 08.18, AS 08.40, 12 AAC 21, 32 and 39). Tab those too.
- Know NEC Article 725 (Class 1, 2 and 3 circuits) and Article 430 control circuits; it is a low-voltage exam (48 volts or less).
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Official reference list (as published by the testing agency)
- National Electrical Code (NFPA 70), 2020 edition
- NFPA 72 National Fire Alarm and Signaling Code, 2013 edition
- Control Systems for Heating, Ventilating, and Air Conditioning, 6th edition
- Alaska Electrical Administrator Statutes and Regulations (AS 08.40; 12 AAC 32)
- Alaska Centralized Regulations and Statutes
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General | 5 | |
| Control Wiring and Equipment | 7 | |
| Class 1,2,3 Circuits | 6 | |
| HVAC Control Wiring | 6 | |
| Manual Control Circuits | 4 | |
| Automatic Control Wiring | 3 | |
| Raceways | 2 | |
| Transformers | 3 | |
| Test Equipment | 2 | |
| Fire Alarm | 4 | |
| Safety | 4 | |
| AK Statutes | 4 |
Exam day details
- Administered by PSI Services for the Alaska Division of Corporations, Business and Professional Licensing (CBPL).
- Fee: $150 to PSI per exam registration (not refundable or transferable). CBPL application and license fees are separate.
- 50 scored questions in 2 hours; 35 correct (70%) to pass. Plus up to 10 unscored experimental items.
- Scope: installation of low-voltage controls and control wiring of 48 volts or less; it does not include power wiring.
- Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed. A silent, non-printing, non-programmable calculator is allowed.
- PSI may add 1 to 10 unscored experimental items, which count against your time.
- The CBPL approves your application first and sends an eligibility letter; the letter is valid for one year, and you may retake as many times as you like in that year (a new fee each time). If you do not pass within the year, you must reapply.
- Since 10/20/2026 the electrical and mechanical administrator exams can be taken remotely or at a PSI test site.
Frequently asked questions
What is on the Alaska controls and control wiring exam?
50 questions: control wiring and equipment 7, Class 1, 2 and 3 circuits 6, HVAC control wiring 6, general 5, manual control circuits 4, fire alarm 4, safety 4, Alaska statutes 4, automatic control wiring 3, transformers 3, raceways 2 and test equipment 2.
How long is it?
Two hours (120 minutes) for 50 questions, 70% to pass.
Free questions with answers
Show all 10 free questions and answers
Two identical relay coils are wired in parallel across a 24-volt control circuit. Each coil has a resistance of 48 ohms. What total current does the circuit draw?
Answer: 1.0 ampere
Parallel resistances: 48 / 2 = 24 ohms total, so I = E / R = 24 V / 24 ohms = 1.0 A. Each coil draws 24 / 48 = 0.5 A and the branch currents add (0.5 + 0.5 = 1.0 A). 0.5 A is a single coil, and 0.25 A comes from wrongly adding the coils in series (96 ohms).
Reference: General practice (HVAC controls), Ohm's law, parallel circuits
Which of the following may serve as the power source for a Class 2 circuit under 725.121?
Answer: A listed Class 2 transformer
Section 725.121(A) permits a listed Class 2 or Class 3 transformer, a listed power supply, or other listed equipment marked as a Class 2 or Class 3 source. Listing and marking, not just a low output voltage or a small breaker, is what makes the source power-limited.
Reference: 2020 National Electrical Code (NFPA 70), 725.121(A)
A remote-control circuit operates safety-control equipment, and failure of that equipment to operate would create a direct fire or life hazard. How does the 2020 NEC classify this circuit?
Answer: Class 1 remote-control circuit
Under 725.31, remote-control circuits for safety-control equipment are classified as Class 1 where failure of the equipment to operate introduces a direct fire or life hazard, and they receive added physical protection where damage would create that hazard. Class 2 and 3 wiring is not acceptable for these circuits.
Reference: 2020 National Electrical Code (NFPA 70), 725.31
A 24-volt thermostat circuit has an unacceptable voltage drop because the run is long. Which change corrects it most directly?
Answer: Install a larger conductor, such as 16 AWG instead of 18 AWG
Voltage drop equals current times conductor resistance, and resistance falls as conductor size increases (a smaller AWG number). A larger conductor, or a shorter run, reduces the drop. A smaller conductor or a lower-VA transformer makes regulation worse.
Reference: General practice (HVAC controls), Voltage drop in low-voltage circuits
In a three-wire start/stop motor control circuit, which part provides the holding (seal-in) function after the START button is released?
Answer: A normally open auxiliary contact wired across START
The starter's N.O. auxiliary contact closes when the coil energizes and, wired in parallel with START, keeps the coil energized when START is released. The N.C. STOP and the overload contact are series devices that break the circuit.
Reference: General practice (HVAC controls), Three-wire motor control
A furnace control circuit has a high-limit, a rollout switch and a pressure switch, all required to be satisfied before the gas valve opens. How are they wired?
Answer: In series with the gas valve circuit
Safety devices are wired in series so that any single open contact interrupts the circuit and de-energizes the gas valve. In parallel, one closed contact would bypass the others.
Reference: General practice (HVAC controls), Safety interlock circuits
A 480-volt to 24-volt control transformer has what turns ratio?
Answer: 20 to 1
Turns ratio equals primary voltage divided by secondary voltage: 480 / 24 = 20, so 20:1. 10:1 and 5:1 do not match the voltages.
Reference: General practice (HVAC controls), Transformer turns ratio
Which conductor material is permitted for fire alarm system wiring?
Answer: Solid or stranded copper only
Fire alarm conductors are required to be copper; 760.49 covers sizes (18 and 16 AWG with loads within Table 402.5) and insulation. Aluminum and copper-clad aluminum are not permitted for fire alarm circuits.
Reference: 2020 National Electrical Code (NFPA 70), 760.49
What does 29 CFR 1926.416(a)(1) require before an employee works so close to an electric power circuit that contact is possible?
Answer: Deenergize and ground the circuit, or guard it effectively
The employer may not permit work in proximity to an electric power circuit unless the employee is protected against shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.
Reference: 29 CFR 1926, 1926.416(a)(1)
Which experience satisfies 12 AAC 32.255(1) for an applicant in the controls and control wiring category?
Answer: Two of the last four years as a journeyman installing 48-volt or lower controls
Section 32.255(1) calls for practical experience as a journeyman installing low voltage controls of 48 volts or less for at least two of the four years immediately before the date of application. Two other options involve management experience or engineering registration.
Reference: Alaska Administrative Code, 12 AAC 32, 12 AAC 32.255(1)
Sources
- PSI: Alaska Electrical Administrators Examination Candidate Information Bulletin (updated 10/15/2026) (opens in a new tab)
- Alaska Division of Corporations, Business and Professional Licensing (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.