Requirements at a glance
| Agency | Alaska Department of Labor and Workforce Development, Mechanical Inspection (state-run exam, not PSI) |
|---|---|
| Experience | 4,000 hours as an Alaska trainee in residential or commercial work (at most 500 classroom hours) (8 AAC 90.164) |
| Exam | Open book, 70% to pass, 4-hour maximum; the number of questions and topic weights are not published |
| Books allowed | 2020 NEC (open book) |
| Fees | $50 non-refundable application fee, then a $200 certificate fee when issued |
Electrician trainees in Alaska with 4,000 hours of residential or commercial work who apply to Mechanical Inspection for a residential wireman certificate of fitness.
Official links
How to get licensed, step by step
Hold a trainee certificate
Alaska counts experience only while you hold a trainee certificate of fitness in the trade, and only in a registered program.
Apply to Mechanical Inspection
Send the application packet, fees and experience verification forms. Processing takes 7 to 10 business days before you can schedule.
Take the residential wireman exam
The Department tests in Anchorage, Juneau and Fairbanks on the first and third Wednesday of each month; job centers, union halls and approved proctors cover other places. Bring a government photo ID.
Mechanical Inspection: testing information and study guides (opens in a new tab)
Retest if needed
If you fail, wait 30 days from the date of your last exam. Results are emailed to you.
Mechanical Inspection: testing information and study guides (opens in a new tab)
How to prepare
- The state publishes no blueprint. Our questions are a balanced mix of the code book on the Department's study guide list, so use them to learn where things are in the book.
- The exam is open book, so practice finding answers quickly in a tabbed copy of the code. Confirm the books and format with Mechanical Inspection at 907-269-4925.
- The scope is residential; on commercial sites a residential wireman counts as a trainee.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Official reference list (as published by the testing agency)
- National Electrical Code (NFPA 70), 2020 edition (open book, per the Mechanical Inspection study guide list)
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| General NEC 2020: Definitions and Requirements | 6 | |
| General NEC 2020: Services and Feeders | 10 | |
| General NEC 2020: Branch Circuits and Load Calculations | 10 | |
| General NEC 2020: Grounding and Bonding | 8 | |
| General NEC 2020: Wiring Methods and Conductors | 12 | |
| General NEC 2020: Lighting, Appliances and Receptacles | 8 | |
| General NEC 2020: Safety and Special Equipment | 6 |
Exam day details
- Administered by State of Alaska Department of Labor and Workforce Development, Mechanical Inspection (not PSI).
- Fee: No separate exam fee is listed. Mechanical Inspection charges a $50 non-refundable application fee and a $200 certificate fee when issued.
- Residential wireman certificate (8 AAC 90.164): 4,000 hours as a trainee (500 classroom hours at most), exam, $50 application fee and a $200 certificate fee. On commercial sites the holder counts as a trainee-level electrician.
- If you fail, wait 30 days from the date of your last exam before retesting.
- State-run, open book, 70% to pass, 4-hour maximum. The Department publishes no question count or topic weights.
- Mechanical Inspection tests in Anchorage, Juneau and Fairbanks on the first and third Wednesday of each month; job centers, union halls and approved proctors cover other places. Approval of your application packet takes 7 to 10 business days before you can schedule.
Note: The Alaska Department of Labor does not publish the number of questions or topic weights for certificate of fitness exams. Our topic split and 60-question practice length are estimates, and a TODO(verify) remains on the exact books and scope. Check with Mechanical Inspection at 907-269-4925.
Frequently asked questions
How many questions are on the Alaska residential wireman exam?
The Department of Labor does not publish a question count or topic weights. The limit is 4 hours and the pass score is 70%.
What can a residential wireman do?
Work described in 8 AAC 90.900(18); on commercial sites the holder is treated as a trainee-level electrician (8 AAC 90.165(d)).
Free questions with answers
Show all 10 free questions and answers
Under the Article 100 definitions of the 2020 NEC, how long must a load be expected to run at maximum current to be a continuous load?
Answer: Three hours or more
Article 100 defines a continuous load as one where the maximum current is expected to continue for 3 hours or more. Continuous loads are sized at 125 percent in rules such as 210.19(A)(1) and 210.20(A); a one- or two-hour load is not continuous.
Reference: 2020 National Electrical Code (NFPA 70), Article 100, Definitions: Continuous Load
A 120/240-volt service drop cabled with a bare messenger is attached to a house. What is the minimum clearance above final grade at the lowest point of the drip loop at the building entrance?
Answer: 10 feet
230.24(B)(1) allows 10 ft at the service entrance to a building, at the lowest point of the drip loop, and over pedestrian-only areas for cabled service drops of 150 volts or less to ground. The 12 ft value applies over residential driveways and 15 ft or 18 ft apply to other areas.
Reference: 2020 National Electrical Code (NFPA 70), 230.24(B)(1)
What is the minimum clearance above final grade for 120/240-volt overhead service-drop conductors that cross a public street?
Answer: 18 feet
230.24(B)(4) requires 18 ft over public streets, alleys, roads and parking areas subject to truck traffic. Lower clearances apply over driveways and pedestrian areas; they do not apply over a public road.
Reference: 2020 National Electrical Code (NFPA 70), 230.24(B)(4)
A homeowner has a bedroom circuit extended with 15 feet of new cable to serve three added receptacle outlets. What AFCI protection does 210.12 require for the modified circuit?
Answer: AFCI at the origin or first outlet
210.12(D) requires a modified or extended branch circuit in the listed living areas of a dwelling to be protected by a listed combination-type AFCI at the circuit origin or a listed outlet branch-circuit AFCI at the first outlet. The small-extension exception covers only short extensions (6 ft or less) with no added outlets or devices.
Reference: 2020 National Electrical Code (NFPA 70), 210.12(D)
Which of these new-dwelling receptacle locations is one where 125-volt, 15- and 20-ampere receptacles must have GFCI protection?
Answer: An unfinished basement
210.8(A) lists the dwelling locations that need GFCI protection, including bathrooms, garages, outdoors, crawl spaces, unfinished basements and kitchen countertops. Hallway, dining room and bedroom receptacles away from sinks need AFCI protection, not GFCI.
Reference: 2020 National Electrical Code (NFPA 70), 210.8(A)
A dwelling service uses 4/0 AWG aluminum service-entrance conductors. Under Table 250.66, what is the smallest copper grounding electrode conductor to the metal underground water pipe electrode?
Answer: 4 AWG
In Table 250.66 the row for 4/0 or 250 kcmil aluminum conductors lists a 4 AWG copper (or 2 AWG aluminum) grounding electrode conductor. The 6 AWG limit in 250.66(A) applies only when the conductor goes to a rod, pipe or plate alone, not to a water pipe.
Reference: 2020 National Electrical Code (NFPA 70), Table 250.66
Six 10 AWG THHN copper conductors share a raceway in a 40 C attic. Using the 90 C column of Table 310.16 (40 A) and applying both the temperature correction and the adjustment factor, what ampacity results?
Answer: 29.1 amperes
Table 310.15(B)(1) gives a 0.91 factor at 40 C for 90 C insulation, and Table 310.15(C)(1) gives 80 percent for 4 to 6 conductors. 40 x 0.91 x 0.80 = 29.12 A. Using only the adjustment gives 32 A, only the correction gives 36.4 A, and 30 A is the 60 C table value, which was not adjusted.
Reference: 2020 National Electrical Code (NFPA 70), Table 310.16; 310.15(B)(1); 310.15(C)(1)
Insulated conductors will be installed in conduit run exposed on the outside wall of a house, where water can enter the raceway. Which conductor marking is suitable?
Answer: THWN-2
300.9 treats the interior of raceways in wet locations above grade as a wet location, and 310.10(C) requires conductors there to be of a type listed for wet locations. THWN-2 is wet-rated (Table 310.4(1), which was Table 310.104(A) before the 2020 renumbering). Conductors marked only THHN or TFN are rated for dry and damp locations, and a 600-volt rating says nothing about wet-location suitability.
Reference: 2020 National Electrical Code (NFPA 70), 300.9; 310.10(C); Table 310.4(1)
A rooftop furnace on a dwelling needs a service receptacle outlet under 210.63. Which location meets the rule?
Answer: On the same level and within 25 feet, not on the disconnect's load side
210.63 requires a 125-volt, 15- or 20-ampere receptacle at an accessible location for servicing heating, air-conditioning and refrigeration equipment, on the same level and within 25 ft of it, and not connected to the load side of the equipment disconnect.
Reference: 2020 National Electrical Code (NFPA 70), 210.63
Which statement about the arc-flash hazard warning label in 110.16(A) is correct?
Answer: It applies to equipment in other than dwelling units, so a dwelling panelboard is exempt
110.16(A) requires a field-applied arc-flash hazard warning on switchboards, panelboards, industrial control panels, meter socket enclosures and motor control centers that are likely to need work while energized, in other than dwelling units. The label is not voltage-limited to 600 V and does not wait for a study.
Reference: 2020 National Electrical Code (NFPA 70), 110.16(A)
Sources
- Alaska DOLWD Mechanical Inspection: testing information (opens in a new tab)
- Alaska DOLWD Labor Standards and Safety: Mechanical Inspection (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.