North Carolina Heating Group 2 (Commercial Forced Air) Contractor Exam: Practice Test & Licensing Guide

The PSI exam for North Carolina Heating Group 2 (Class I and II) contractor licenses: integral air systems with more than 15 tons of mechanical refrigeration. A 4-hour open-book exam on the 2018 NC Mechanical, Fuel Gas and Energy Codes, ACCA manuals and refrigeration.

Questions
Not published by North Carolina
Time limit
4 hours
Passing score
Not published by North Carolina

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Ventilation, Exhaust and Combustion Air

A rooftop unit's outdoor air intake is being located near a loading dock on a commercial building. What is the minimum horizontal distance required between the intake opening and the loading dock?

Requirements at a glance

AgencyNC State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors; exams by PSI
ExamHeating Group 2 (forced air, over 15 tons) contractor exam, 4 hours, open book (question count and pass score are not published)
Books allowed2018 NC Mechanical, Fuel Gas, Administrative and Energy Codes and the ACCA and refrigeration books on the Board's Group 2 list; duct calculator
Fees$150 by examination: $75 Board application plus $75 nonrefundable PSI exam fee (valid one year), per 21 NCAC 50 .1101(c); then the annual license fee ($150 for contractors, .1102)

Anyone qualifying a Heating Group 2 contractor license from the NC State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors. Under G.S. 87-21(a)(3), Group 2 is an air-circulating heating or cooling system with more than 15 tons of mechanical refrigeration; systems in single-family residences belong to Group 3 regardless of size.

How to get licensed, step by step

  1. Apply to the Board

    Contact the Board (1109 Dresser Court, Raleigh; 919-875-3612) and submit the exam application for your license type.

    NC State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors (opens in a new tab)

  2. Wait for PSI's email

    Once approved you get an email confirmation from PSI, then register and pay the $75 exam fee (the $75 application fee goes to the Board). After you pass, pay the license fee ($150 a year for contractors) within 45 days.

    Schedule with PSI (NC plumbing, heating and fire sprinkler) (opens in a new tab)

  3. Check your book list

    Only the books for your exam category are allowed in the room. The Board's list is effective July 1, 2025; confirm it before you buy.

    NC Board: exam information, book list and 2018 code notice (opens in a new tab)NC Office of State Fire Marshal: code book sales (opens in a new tab)

  4. Take the exam and Business and Law

    Business and Law is a separate Board exam unless you hold an active license and passed it after August 2003.

    Schedule with PSI (NC plumbing, heating and fire sprinkler) (opens in a new tab)

How to prepare

  • North Carolina's exams use the 2018 NC State Building Code (2015 ICC base text with NC amendments, effective 2019). The 2024 NC codes are delayed to no earlier than May 1, 2027, so use the 2018 books.
  • Tab your books with permanent tabs before exam day. Highlighting is allowed; writing, sticky flags and loose papers are not.
  • Group 2 is air systems over 15 tons (G.S. 87-21(a)(3)); expect commercial ventilation, load and refrigeration questions.
  • Tab the NC Mechanical Code ventilation, duct and refrigeration chapters and the Energy Code commercial provisions.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 NC Mechanical Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • North Carolina State Building Code: Mechanical Code, 2018 (2015 IMC with NC amendments)
  • North Carolina State Building Code: Fuel Gas Code, 2018 (2015 IFGC with NC amendments)
  • North Carolina State Building Code: Administrative Code and Policies, 2018
  • North Carolina State Building Code: Energy Conservation Code, 2018
  • ACCA manuals and Modern Refrigeration and Air Conditioning (Goodheart-Willcox), 22nd Edition, as listed for your class
  • A duct calculator (bring your own)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Administration and General Regulations6
Ventilation, Exhaust and Combustion Air14
Duct Systems and Air Distribution14
Heating and Cooling Load Calculations14
Chimneys, Vents and Appliance Installation10
Fuel Gas Piping and Appliances8
Hydronic Piping and Boilers8
Refrigeration Systems and Equipment18
Energy Code Requirements8

Exam day details

  • Administered by PSI Services for the NC State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors.
  • Fee: $150 for a license by examination (21 NCAC 50 .1101(c)): $75 Board application fee plus $75 nonrefundable exam fee paid to PSI (valid one year). After you pass, pay the annual license fee ($150 for a contractor license, .1102).
  • 4 hours, open book. The Board does not publish the number of questions, the pass score or a topic outline.
  • The Board's book list is class-specific (Class I, Class II and technician); only the books for your category are allowed in the room. Confirm yours on the Board's site.
  • Heating exams are based on the 2018 NC codes until the 2024 codes take effect (no earlier than May 1, 2027).
  • Open book: bring your own reference books in original published condition (hard-, spiral- or ring-bound), only the books listed for your exam. Highlighting and permanent commercial tabs (ICC Turbo Tabs are the only loose inserts) are allowed; writing, underlining, notes and homemade tabs are not. Printed PDFs are not allowed.
  • PSI provides pencils, scratch paper, calculators and the NC Heating and Plumbing Figures. Heating candidates bring their own duct calculator.
  • You must apply to the Board first; PSI emails you after approval. A license by examination costs $150 ($75 application fee plus a $75 nonrefundable exam fee paid to PSI, valid one year); after you pass, the annual license fee ($150 for contractors) is due within 45 days.
  • You cannot retest the same day. Unauthorized materials in the exam room mean a 90-day wait before you can reschedule.
  • Business and Law is a separate exam, not required if you hold an active license and passed the Board's Business and Law exam after August 2003.

Note: The Board publishes exam durations and reference books for each exam but not the number of questions, a pass score or a topic outline. The question count, pass score and topic weights on this page are our practice estimates. The Board's note dated June 1, 2026 says exams stay on the 2018 NC codes (including NFPA 13 and 13D 2013 and NFPA 25 2011) until the 2024 codes take effect, no earlier than May 1, 2027.

Frequently asked questions

What does Heating Group 2 cover in North Carolina?

An integral heating or cooling system that circulates air and has more than 15 tons of mechanical refrigeration (G.S. 87-21(a)(3)). Single-family residential systems are Group 3 regardless of size.

How many questions are on the NC Heating Group 2 exam?

The Board and PSI publish only the 4-hour time limit. This practice exam uses 80 questions as a working length.

What books do I need?

Only the books on the Board's list for your class; confirm it on the Board's site before you buy.

Free questions with answers

Show all 10 free questions and answers
  1. A rooftop unit's outdoor air intake is being located near a loading dock on a commercial building. What is the minimum horizontal distance required between the intake opening and the loading dock?

    Answer: 10 feet

    Section 401.4, Item 2 requires mechanical and gravity outdoor air intake openings to be at least 10 feet horizontally from hazardous or noxious contaminant sources such as vents, streets, alleys, parking lots and loading docks. The 3-foot figure is the vertical separation below a contaminant source within 10 feet (Item 3), not the horizontal distance.

    Reference: 2018 North Carolina Mechanical Code (2015 IMC with NC amendments), Section 401.4

  2. A commercial supply duct system has a design operating pressure of 2.7 inches of water column. Based on the classifications in Section 603.3, what is the lowest pressure class that can be used for the ducts?

    Answer: 3 inches w.c.

    Section 603.3 lists duct pressure classes of 0.5, 1, 2, 3, 4, 6 and 10 inches w.c., and the classification must equal or exceed the design pressure of the system. The lowest class at or above 2.7 inches is 3 inches. A 2-inch class is below the design pressure; 4 and 6 are allowed but not the lowest.

    Reference: 2018 North Carolina Mechanical Code (2015 IMC with NC amendments), Section 603.3

  3. Section 1101.6 says refrigeration systems must comply with the mechanical code and, except as modified by it, with which standard?

    Answer: ASHRAE 15

    Section 1101.6 requires refrigeration systems to comply with Chapter 11 and, except as modified by the code, ASHRAE 15 (the safety standard for refrigeration systems). Ammonia systems must also comply with IIAR 2. ASHRAE 62.1 covers ventilation and ASHRAE 90.1 covers energy; NFPA 54 is the fuel gas code.

    Reference: 2018 North Carolina Mechanical Code (2015 IMC with NC amendments), Section 1101.6

  4. A 400 square foot machinery room is normally occupied by three people. Using only the airflow criterion based on room area or occupants in Section 1105.6.3.1, what is the minimum normal ventilation exhaust rate?

    Answer: 200 cfm

    Section 1105.6.3.1, Item 1 requires not less than 0.5 cfm per square foot of machinery room area or 20 cfm per person: 400 x 0.5 = 200 cfm, versus 3 x 20 = 60 cfm. The larger value governs, so 200 cfm. (Item 2 separately requires enough airflow to limit the room temperature rise to 18 degrees F; the larger of the two items governs.) 260 cfm adds the two rates.

    Reference: 2018 North Carolina Mechanical Code (2015 IMC with NC amendments), Section 1105.6.3.1

  5. A roof assembly has an outside air film of R-0.17, roofing of R-0.44, rigid insulation of R-20, a metal deck of R-0.06 and an inside air film of R-0.61. What is the total R-value and the U-factor of the assembly?

    Answer: R-21.28 and U = 0.047

    Series resistances add: 0.17 + 0.44 + 20 + 0.06 + 0.61 = 21.28. U = 1 / R = 1 / 21.28 = 0.047 Btu/h-ft2-F. R-20 counts the insulation alone; U = 21.28 forgets to invert; R-1.28 leaves out the insulation.

    Reference: ACCA Manual J, 8th Edition, Version 2, series thermal resistance (U = 1 / total R)

  6. A Type B gas vent serves a draft-hood-equipped unit heater in a warehouse. How far above the draft hood must the vent terminate in vertical height?

    Answer: Not less than 5 feet above the highest connected draft hood or flue collar

    Section 503.6.5 requires a Type B or L gas vent to terminate at least 5 feet in vertical height above the highest connected appliance draft hood or flue collar. The 12-foot figure applies to Type B-W vents serving wall furnaces, measured from the bottom of the furnace.

    Reference: 2018 North Carolina Fuel Gas Code (2015 IFGC with NC amendments), Section 503.6.5

  7. Which test medium is permitted for the pressure test of fuel gas piping under Section 406.2?

    Answer: Air, nitrogen, carbon dioxide or another inert gas

    Section 406.2 allows air, nitrogen, carbon dioxide or an inert gas as the test medium and prohibits oxygen. Testing with fuel gas from the supply is not listed. Note that the refrigeration chapter of the mechanical code (Section 1108.2) is stricter and does not allow air.

    Reference: 2018 North Carolina Fuel Gas Code (2015 IFGC with NC amendments), Section 406.2

  8. A new commercial boiler has a fuel input of 15,000,000 Btu/h. Which standard must its controls and safety devices meet under Section 1004.1?

    Answer: NFPA 85, because the input exceeds 12,500,000 Btu/h

    Section 1004.1 requires controls and safety devices for boilers with fuel input of 12,500,000 Btu/h or less to meet ASME CSD-1, and for boilers with input greater than 12,500,000 Btu/h to meet NFPA 85. At 15,000,000 Btu/h, NFPA 85 applies. UL 726 is the listing standard for packaged oil-fired boilers.

    Reference: 2018 North Carolina Mechanical Code (2015 IMC with NC amendments), Section 1004.1

  9. A mechanical permit was issued for a chiller replacement, and work started in February. Work then stopped and did not resume for 13 months. What is the status of the permit under Section 204.3.2?

    Answer: It has expired, and a new permit is needed before more work

    Section 204.3.2 states that if work is discontinued for a period of 12 months after commencement, the permit immediately expires, and no work authorized by an expired permit may be performed until a new permit has been issued. (A permit also expires 6 months after issuance, or any shorter local period, if the work has not commenced.)

    Reference: 2018 North Carolina Administrative Code and Policies (NC amendments), Section 204.3.2

  10. A supply duct is installed outdoors on a commercial rooftop in Climate Zone 4. What minimum insulation does NC Section C403.2.9 require?

    Answer: R-8

    Section C403.2.9 (NC amendment 221213 Item A-8) requires supply and return ducts located outdoors to have at least R-8 insulation in Climate Zones 3 and 4 and at least R-12 in Climate Zone 5. R-6 is the requirement for unconditioned spaces inside the building, and R-12 applies only in Zone 5. (The temporary R-4/R-6 rule under Session Law 2022-46 expired March 17, 2024.)

    Reference: 2018 North Carolina Energy Conservation Code (2015 IECC with NC amendments), Section C403.2.9