Question 1 of 10Permits and General Regulations

A homeowner plans a one-story detached workshop measuring 14 ft by 14 ft (196 square feet) behind the house. Under the 2018 IRC administrative provisions, is a building permit required for the workshop itself?

Requirements at a glance

AgencyYour Missouri city or county licenses you; the International Code Council (ICC) gives the exam through Pearson VUE. There is no statewide plumbing, HVAC or general contractor license
Where it is usedKansas City (G13 Residential Building Contractor C); Independence accepts ICC general contractor scores
ExamG13: 80 questions, 4 hours
Books allowed2018 International Residential Code and ICC Concrete Manual (2015)
Fees$115 per ICC exam through Pearson VUE, plus your city's license fees

Residential builders and remodelers applying for a Kansas City residential building contractor certificate, or a similar license from a Missouri city that accepts the ICC exam.

How to get licensed, step by step

  1. Ask your city or county which exam it accepts

    Missouri cities and counties set their own licenses and exams. Confirm the exam, the experience rules and any local code amendments before you pay. Kansas City amendments, fees and rules are not verified on this site.

    ICC: Contractor/Trades exam catalog (outlines, references, passing score) (opens in a new tab)

  2. Apply to the city first

    Springfield's ICC bulletin says to make your license application to Building Development Services before you schedule; wait for its approval, then register for the exam.

    ICC: Contractor/Trades exam catalog (outlines, references, passing score) (opens in a new tab)

  3. Register for the residential building contractor exam with ICC and Pearson VUE

    Create an account, find the exam in the ICC Exam Catalog and schedule a Pearson VUE appointment. If you fail, wait 10 days to retake.

    Schedule with Pearson VUE (ICC exams) (opens in a new tab)

  4. Pass with your books

    The exam is open book with four-option multiple choice and no penalty for guessing. The ICC bulletins print no passing score, so check the Exam Catalog; 75% is the usual ICC trade standard.

    ICC: Contractor/Trades exam catalog (outlines, references, passing score) (opens in a new tab)

How to prepare

  • Study the edition the exam is built on (listed above), not the newer code your city may enforce.
  • The exam is open book, but there is not time to look up every answer. Tab your books by chapter and table before exam day.
  • Structural systems (46%) is almost half the exam: footings, foundations, floors, wall framing, roof construction and stairs in IRC Chapters 4 through 8.
  • Planning and life safety (24%) draws on IRC Chapter 3: R301 design criteria, R302 fire-resistant construction, R310 emergency escape, R311 means of egress and R314/R315 alarms.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • 2018 International Residential Code (IRC)Essential

    Allowed in the exam room. The code for one- and two-family dwellings: design criteria, foundations, framing, roofs and life safety.

    ICC store (opens in a new tab)

  • ICC Concrete Manual (2015)

    Allowed in the exam room. Listed on the Kansas City residential building contractor outline.

    ICC store (opens in a new tab)

Official reference list (as published by the testing agency)
  • 2018 International Residential Code (IRC) (allowed in the exam room)
  • ICC Concrete Manual (2015) (allowed in the exam room)

What's on the exam

Official content outline from International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):

TopicQuestions
Permits and General Regulations18
Building Planning and Life Safety24
Structural Systems46
Building Envelope12

The outline totals 100; the other items on the 80-question exam are unscored or unassigned.

Exam day details

  • Administered by International Code Council (ICC), delivered by Pearson VUE, for Missouri cities and counties.
  • Fee: $115 to ICC through Pearson VUE per exam (ICC bulletins for Kansas City and Springfield). Your city's license fees are separate.
  • 80 multiple-choice questions in 4 hours; passing score not published (75% used as practice target).
  • Open book: bring the approved references listed for the exam. Questions are four-option multiple choice with no penalty for guessing.
  • Missouri has no statewide plumbing, HVAC or general contractor license. Each city or county names the exams it accepts and issues the license. Apply to the city first; once it approves you, schedule the ICC exam with Pearson VUE.
  • If you fail, wait 10 days to retake (ICC bulletin).

Note: The ICC bulletins for Missouri cities print no passing score: they send candidates to the ICC Exam Catalog on Pearson VUE. ICC's default is 70%, but jurisdictions may set it higher: older ICC bulletins required 75% for Columbia (2017) and St. Louis County (2018), and Independence accepts ICC scores of 75% or more. We use 75% as a practice target; confirm the passing score in the Exam Catalog before you test. Kansas City, Columbia and Lee's Summit publish their rules on sites we could not read, so check amendments, fees and experience rules with the city.

Frequently asked questions

What's on the Missouri residential building contractor exam?

80 questions by weight: structural systems 46%, building planning and life safety 24%, permits and general regulations 18% and building envelope 12%.

Which code books does it use?

The 2018 International Residential Code and the ICC Concrete Manual (2015), per the Kansas City bulletin.

Is there a state general contractor license?

No. Cities such as Kansas City and Independence license residential builders locally.

Free questions with answers

Show all 10 free questions and answers
  1. A homeowner plans a one-story detached workshop measuring 14 ft by 14 ft (196 square feet) behind the house. Under the 2018 IRC administrative provisions, is a building permit required for the workshop itself?

    Answer: No, a one-story detached accessory structure not over 200 square feet is exempt

    R105.2 exempts one-story detached accessory structures whose floor area does not exceed 200 square feet (14 x 14 = 196). The exemption never excuses violating other code or zoning provisions, but no permit is required for the structure itself.

    Reference: 2018 International Residential Code, R105.2 Work Exempt From Permit

  2. A freestanding wood deck, not attached to the house and not serving the required exit door, is 150 square feet and stands 34 inches above grade at its highest point. Under R105.2, what is the permit status?

    Answer: A permit is required because the deck is more than 30 inches above grade

    The R105.2 deck exemption requires every condition at once: not over 200 square feet, not more than 30 inches above grade at any point, not attached to a dwelling, and not serving the R311.4 exit door. At 34 inches the height condition fails, so a permit is needed even though area and attachment qualify.

    Reference: 2018 International Residential Code, R105.2 Work Exempt From Permit

  3. A permit application stalled for lack of a structural detail and will reach the 180-day abandonment point next week, but the applicant is still working on the detail. How does R105.3.2 let the application stay alive?

    Answer: The building official may grant extensions of up to 180 days each, requested in writing with justifiable cause

    R105.3.2 deems an application abandoned 180 days after filing unless pursued in good faith or a permit has been issued. The building official can grant one or more extensions, each not over 180 days, if requested in writing and justifiable cause is shown.

    Reference: 2018 International Residential Code, R105.3.2 Time Limitation of Application

  4. A second-floor bedroom has a casement window whose net clear opening, measured with the sash fully open, is 26 inches high by 30 inches wide, with the sill 36 inches above the floor. Does it meet the 2018 IRC emergency escape and rescue opening size requirements?

    Answer: No, it provides 5.42 square feet and an upper-story opening needs at least 5.7 square feet

    R310.2.1 requires a net clear opening of at least 5.7 sq ft, with net clear height of at least 24 in and width of at least 20 in. The 5 sq ft exception applies only to grade floor or below-grade openings. 26 x 30 = 780 sq in; 780 / 144 = 5.42 sq ft, which is under 5.7, so the window fails even though height, width and the 44-inch sill are fine.

    Reference: 2018 International Residential Code, R310.2.1 Minimum Opening Area

  5. An inspector measures the handrail on a new interior stair, with 13 risers, at 40 inches vertically above the sloped plane of the tread nosings. What does R311.7.8.1 say about this handrail?

    Answer: It is too high, because handrail height must be from 34 to 38 inches above the nosings

    R311.7.8 requires a handrail on at least one side of each flight with four or more risers, and R311.7.8.1 sets handrail height, measured vertically from the sloped plane adjoining the tread nosings, at not less than 34 and not more than 38 inches. 40 inches is above the limit.

    Reference: 2018 International Residential Code, R311.7.8.1 Height

  6. A porch floor stands 44 inches above the ground and the porch is open on three sides. Under R312, what is the minimum guard height on the porch, and what sphere must not pass through any opening in the guard?

    Answer: 36 inches high, with openings that do not pass a 4-inch sphere

    R312.1.1 requires guards on open-sided walking surfaces more than 30 inches above the floor or grade below. R312.1.2 sets the guard height at porches at not less than 36 inches, and R312.1.3 limits openings to those that do not allow a 4-inch sphere to pass. The 34-inch height is for the open side of a stair.

    Reference: 2018 International Residential Code, R312.1.2 Height

  7. A 14-foot-long wood sill plate section sits on a concrete foundation wall and is anchored with 1/2-inch-diameter anchor bolts. The end bolts are placed 12 inches from each end of the plate section. What is the minimum number of bolts if no bolt spacing may exceed 6 feet on center, per R403.1.6?

    Answer: Three bolts: the 12 feet between the end bolts needs one more bolt to keep spacing at 6 feet or less

    R403.1.6 requires 1/2-inch anchor bolts at not more than 6 feet on center, with at least two bolts per plate section and one bolt within 12 inches (and not less than seven bolt diameters, 3 1/2 inches) of each end. 14 ft - 2 x 1 ft = 12 ft between end bolts; 12 / 6 = 2 spaces, so 3 bolts. Two bolts would leave a 12-foot gap.

    Reference: 2018 International Residential Code, R403.1.6 Foundation Anchorage

  8. A garage floor slab is to be poured at a site the plans classify as having moderate weathering potential, with a broom finish. According to Table R402.2, what are the minimum specified compressive strength and the air-entrainment requirement?

    Answer: 3,000 psi with total air content of 5 to 7 percent

    Table R402.2 lists porches, carport slabs, steps exposed to the weather and garage floor slabs at 2,500 psi for negligible weathering, 3,000 psi for moderate and 3,500 psi for severe. At moderate and severe potential the concrete must be air-entrained with total air of 5 to 7 percent; only a steel-troweled garage floor may drop to 3 percent, and then at 4,000 psi.

    Reference: 2018 International Residential Code, Table R402.2 Minimum Specified Compressive Strength of Concrete

  9. A small porch addition has a shed roof with a slope of 3:12. The owner wants asphalt shingles. What does R905.2.2 require?

    Answer: Shingles are allowed, with a double underlayment application because the slope is under 4:12

    R905.2.2 permits asphalt shingles only on slopes of 2 units vertical in 12 horizontal or greater. For slopes from 2:12 up to 4:12 a double underlayment application is required per R905.1.1. A 3:12 roof falls in that range.

    Reference: 2018 International Residential Code, R905.2.2 Slope

  10. A vented attic space measures 30 ft by 45 ft. There is no vapor retarder and the 1/300 exception does not apply. According to R806.2, what is the minimum net free ventilating area, in square feet and in square inches?

    Answer: 9 sq ft, which is 1,296 sq in

    R806.2 requires net free ventilating area of at least 1/150 of the vented space unless the 1/300 exception conditions are met. Area = 30 x 45 = 1,350 sq ft. 1,350 / 150 = 9 sq ft; 9 x 144 = 1,296 sq in. Using 1/300 gives 4.5 sq ft, which is allowed only with a vapor retarder in Climate Zones 6 to 8 and with 40 to 50 percent of the vents in the upper portion.

    Reference: 2018 International Residential Code, R806.2 Minimum Vent Area