Missouri licensing exam

Missouri Master Electrician Exam (ICC G16/W16): Practice Test & Licensing Guide

The ICC Master Electrician exam used in Kansas City (G16) and Springfield and Columbia (W16): 100 open-book questions on the 2017 NEC and Ugly's. Missouri OSEC also lists ICC master electrician exams as approved. Passing score not printed in the bulletins.

Questions
100
Time limit
5 hours
Passing score
Not published by Missouri

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge and Plan Reading

A 10 hp motor delivers 7,460 W (746 W per hp) at the shaft and is 85 percent efficient. Single-phase at 240 volts, how much current does it draw at unity power factor?

Requirements at a glance

AgencyYour Missouri city or county licenses you; the International Code Council (ICC) gives the exam through Pearson VUE. There is no statewide plumbing, HVAC or general contractor license
Where it is usedKansas City (G16), Springfield and Columbia (W16). OSEC also accepts ICC master electrician exams for the statewide contractor license
ExamG16 / W16: 100 questions, 5 hours
Books allowed2017 National Electrical Code and Ugly's Electrical References (any edition)
Fees$115 per ICC exam through Pearson VUE, plus your city's license fees

Electricians applying for a master electrician license in Kansas City, Springfield or Columbia, or showing an ICC exam to OSEC for the statewide contractor license.

How to get licensed, step by step

  1. Ask your city or county which exam it accepts

    Missouri cities and counties set their own licenses and exams. Confirm the exam, the experience rules and any local code amendments before you pay. Kansas City amendments, fees and rules are not verified on this site.

    ICC: Contractor/Trades exam catalog (outlines, references, passing score) (opens in a new tab)

  2. Apply to the city first

    Springfield's ICC bulletin says to make your license application to Building Development Services before you schedule; wait for its approval, then register for the exam.

    ICC: Contractor/Trades exam catalog (outlines, references, passing score) (opens in a new tab)

  3. Register for the master electrician exam with ICC and Pearson VUE

    Create an account, find the exam in the ICC Exam Catalog and schedule a Pearson VUE appointment. If you fail, wait 10 days to retake.

    Schedule with Pearson VUE (ICC exams) (opens in a new tab)

  4. Pass with your books

    The exam is open book with four-option multiple choice and no penalty for guessing. The ICC bulletins print no passing score, so check the Exam Catalog; 75% is the usual ICC trade standard.

    ICC: Contractor/Trades exam catalog (outlines, references, passing score) (opens in a new tab)

How to prepare

  • Study the edition the exam is built on (listed above), not the newer code your city may enforce.
  • The exam is open book, but there is not time to look up every answer. Tab your books by chapter and table before exam day.
  • Wiring methods and materials (about 19%), services (16%) and branch circuits (16%) lead. Tab NEC Chapters 2 and 3 and the Chapter 9 tables.
  • This exam uses the 2017 NEC. The PSI NASCLA exams use the 2020 or 2023 NEC, so do not mix the editions.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2017 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2017 EditionEssential

    Allowed in the exam room. The ICC Missouri electrician exams are built on the 2017 edition, not the 2020 or 2023 NEC used by the PSI NASCLA exams.

    NFPA store (opens in a new tab)

  • Ugly's Electrical References (any edition)

    Allowed in the exam room. Formulas for voltage drop, power, motors and load calculations.

Official reference list (as published by the testing agency)
  • 2017 National Electrical Code (NEC) (allowed in the exam room)
  • Ugly's Electrical References (any edition) (allowed in the exam room)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
General Knowledge and Plan Reading12
Services and Service Equipment16
Feeders4
Branch Circuits and Conductors16
Wiring Methods and Materials19
Equipment and Devices10
Control Devices3
Motors and Generators8
Special Occupancies, Equipment, and Conditions12

Exam day details

  • Administered by International Code Council (ICC), delivered by Pearson VUE, for Missouri cities and counties.
  • Fee: $115 to ICC through Pearson VUE per exam (ICC bulletins for Kansas City and Springfield). Your city's license fees are separate.
  • 100 multiple-choice questions in 5 hours; passing score not published (75% used as practice target).
  • Open book: bring the approved references listed for the exam. Questions are four-option multiple choice with no penalty for guessing.
  • Missouri has no statewide plumbing, HVAC or general contractor license. Each city or county names the exams it accepts and issues the license. Apply to the city first; once it approves you, schedule the ICC exam with Pearson VUE.
  • If you fail, wait 10 days to retake (ICC bulletin).

Note: The ICC bulletins for Missouri cities print no passing score: they send candidates to the ICC Exam Catalog on Pearson VUE. ICC's default is 70%, but jurisdictions may set it higher: older ICC bulletins required 75% for Columbia (2017) and St. Louis County (2018), and Independence accepts ICC scores of 75% or more. We use 75% as a practice target; confirm the passing score in the Exam Catalog before you test. Kansas City, Columbia and Lee's Summit publish their rules on sites we could not read, so check amendments, fees and experience rules with the city.

Frequently asked questions

What's on the ICC master electrician exam?

100 questions: wiring methods and materials about 19%, services, branch circuits and special occupancies about 12 to 16% each, equipment and devices 10%, motors and generators 8%, feeders 4% and control devices 3%. The weights are matched to topics by order in the ICC text, so treat them as approximate.

Which NEC edition does it use?

The 2017 NEC with Ugly's Electrical References. It is not the 2020 or 2023 NEC used on the PSI NASCLA exams.

Does OSEC accept it?

OSEC's approved-exam list includes the ICC master electrician exam (G16/F16). Confirm current details with OSEC.

Free questions with answers

Show all 10 free questions and answers
  1. A 10 hp motor delivers 7,460 W (746 W per hp) at the shaft and is 85 percent efficient. Single-phase at 240 volts, how much current does it draw at unity power factor?

    Answer: 36.6 A

    Input power = output / efficiency = 7,460 / 0.85 = 8,776 W. Current = 8,776 / 240 = 36.6 A. 31.1 A uses the output watts without dividing by efficiency, 43.0 A divides by 0.85 twice, and 26.4 A multiplies by the efficiency.

    Reference: NFPA 70, National Electrical Code, 2017, Motor efficiency and power formulas (Ugly's Electrical References)

  2. A multi-tenant commercial building has eight tenant spaces, and the owner wants one service disconnect per tenant grouped at one location. What is the largest number of switches or sets of circuit breakers allowed as the disconnecting means for one service under the 2017 NEC?

    Answer: Six

    Section 230.71(A) allows the service disconnecting means to consist of not more than six switches or sets of circuit breakers, in a single enclosure, in a group of separate enclosures, or in or on a switchboard. Eight tenant disconnects would need to be combined (for example, a main with tenant feeders) to stay within the six-disconnect rule.

    Reference: NFPA 70, National Electrical Code, 2017, 230.71(A)

  3. What is the minimum length of a rod-type grounding electrode under 250.52(A)(5) when it is used as a grounding electrode of the service?

    Answer: 8 ft

    Section 250.52(A)(5) requires rod and pipe electrodes to be not less than 2.5 m (8 ft) long, with 5/8-in. diameter minimum for steel or stainless rods unless listed, and 1/2 in. for listed rods. Shorter rods, such as 4 ft or 6 ft, do not qualify.

    Reference: NFPA 70, National Electrical Code, 2017, 250.52(A)(5)

  4. A 3,000 sq ft dwelling has two 20 A small-appliance circuits and one laundry circuit. Using the standard method, with 3 VA per sq ft for lighting, 1,500 VA per small-appliance circuit and 1,500 VA for the laundry circuit, what is the demand load for these items after the demand factors of Table 220.42?

    Answer: 6,675 VA

    General lighting = 3,000 x 3 = 9,000 VA, small appliance = 2 x 1,500 = 3,000 VA, laundry = 1,500 VA, total 13,500 VA. Table 220.42: first 3,000 VA at 100 percent = 3,000, remaining 10,500 VA at 35 percent = 3,675. Demand = 3,000 + 3,675 = 6,675 VA. 13,500 VA takes no demand factor, 4,725 VA applies 35 percent to the whole, and 6,150 VA leaves out the laundry circuit.

    Reference: NFPA 70, National Electrical Code, 2017, Table 220.42; 220.52; Table 220.12

  5. Eight current-carrying 8 AWG THHN copper conductors share one conduit in an ambient of 40 C (104 F). Using the 90 C ampacity of 55 A in Table 310.15(B)(16), the correction factor of 0.91 and the adjustment factor for 7 to 9 conductors, what is the adjusted ampacity?

    Answer: 35.0 A

    Start with the 90 C value of 55 A. Temperature correction for 36-40 C on the 90 C column is 0.91 (Table 310.15(B)(2)(a)), and 7-9 current-carrying conductors take 70 percent (Table 310.15(B)(3)(a)). 55 x 0.91 x 0.70 = 35.0 A. 38.5 A skips the temperature factor, 40.0 A uses the 80 percent factor for 4-6 conductors, and 50.1 A skips the adjustment factor.

    Reference: NFPA 70, National Electrical Code, 2017, Table 310.15(B)(16); Table 310.15(B)(2)(a); Table 310.15(B)(3)(a)

  6. Using Table 314.16(A), what is the maximum number of 10 AWG conductors permitted in a 4 in. x 2-1/8 in. deep square metal box (30.3 cu in) with no devices, clamps or fittings?

    Answer: 12

    A 4 x 2-1/8 in. square box has 30.3 cu in, and each 10 AWG conductor needs 2.5 cu in (Table 314.16(B)): 30.3 / 2.5 = 12.1, so 12 conductors. 13 is the table figure for 12 AWG, 15 is the figure for 14 AWG, and 10 is the figure for 8 AWG.

    Reference: NFPA 70, National Electrical Code, 2017, Table 314.16(A)

  7. Under 110.24(A), what information must be field marked on the service equipment of a commercial building?

    Answer: The maximum available fault current and the date the calculation was made

    Section 110.24(A) requires service equipment in other than dwelling units to be field marked with the maximum available fault current and the date the fault-current calculation was done. The marking must be updated when modifications change the value (110.24(B)).

    Reference: NFPA 70, National Electrical Code, 2017, 110.24(A)

  8. A cable assembly with a white conductor is used as a switch loop, with the white wire carrying power to a single-pole switch. What does 200.7(C)(1) require of that white conductor?

    Answer: Permanently re-identified with paint or tape where it is visible

    Section 200.7(C)(1) permits a white or gray conductor of a cable to supply a switch loop (feed to a switch) where it is permanently re-identified by painting or other effective means at its terminations and at each location where the conductor is visible and accessible. It may not be used as the return conductor from the switch to the outlet.

    Reference: NFPA 70, National Electrical Code, 2017, 200.7(C)(1)

  9. A single 20 hp, 208-volt, 3-phase continuous-duty induction motor has a Table 430.250 full-load current of 59.4 A and a nameplate current of 56 A. Under 430.22, what is the minimum ampacity of the branch-circuit conductors?

    Answer: 74.3 A

    Branch-circuit conductors for a single continuous-duty motor must carry 125 percent of the full-load current taken from the table (430.6(A)(1)), not the nameplate: 59.4 x 1.25 = 74.25, or 74.3 A. 59.4 A omits the 125 percent, 70.0 A uses the nameplate 56 A, and 92.8 A applies the 125 percent twice.

    Reference: NFPA 70, National Electrical Code, 2017, 430.22; Table 430.250; 430.6(A)(1)

  10. Under 501.15(A)(1), how close to an enclosure that houses arcing contacts must a conduit seal be installed in a Class I, Division 1 location?

    Answer: Within 18 in. of the enclosure

    Section 501.15(A)(1) requires a seal in each conduit entering an enclosure that houses arcing or high-temperature devices in a Class I, Division 1 location, located as close as practicable and in no case more than 18 in. from the enclosure. 10 ft applies to the boundary seal in 501.15(A)(4).

    Reference: NFPA 70, National Electrical Code, 2017, 501.15(A)(1)

Sources

Questions last verified November 12, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.