Requirements at a glance
| Agency | Minnesota Department of Labor and Industry (DLI); Plumbing Board sets the rules |
|---|---|
| Experience | 12 months as a licensed water conditioning journeyworker, or 12 months (1,750 hours) of practical experience including installation, servicing, planning and supervising hours (Rules 4716.0092) |
| Exam | 65 questions, 3 hours, 70% to pass |
| Books allowed | None of your own: DLI supplies the 2020 Minnesota Plumbing Code (without tabs), the laws-and-rules booklet and a calculator |
| Fees | $50 per personal-license exam (Minn. Stat. 326B.092), plus application and license fees |
Water conditioning contractors applying to DLI for a master license after 12 months as a licensed water conditioning journeyworker or 12 months of practical experience.
Official links
How to get licensed, step by step
Apply to DLI
Send DLI your water conditioning master application, proof of experience and the $50 exam fee. A water conditioning contractor business needs a designated licensed master.
Minnesota Department of Labor and Industry (DLI) (opens in a new tab)DLI: plumbing license basics (opens in a new tab)
Schedule your exam
After DLI approves your application, you schedule the exam in DLI's iMS system. DLI gives exams at its St. Paul office (Tuesday to Thursday) and at outstate sites including Duluth, Mankato, Rochester and St. Cloud.
Take the exam
You have 3 hours and need 70%. The exam is open book with DLI-supplied references; no personal books, notes or electronic devices.
DLI: plumbing license basics (opens in a new tab)DLI Plumbing License Examination Guide (PDF) (opens in a new tab)
Results and retakes
DLI mails results in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
How to prepare
- The exam is based on the 2020 Minnesota Plumbing Code (Rules 4714), mainly Chapter 6 and Rules 4714.0611 on water conditioning equipment, plus Rules 4716 and Statutes 326B.50 to 326B.59. DLI's guide is one checklist for several plumbing licenses, so only some rows apply to you.
- Know the Rules 4714.0611 items cold: NSF standards for wetted surfaces, labeling, airgap discharge, connection tubing, residential softener sizing and isolation and bypass valves.
- Every DLI exam is open book, but with DLI-supplied references only: a code book without tabs, the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, so practice finding answers fast rather than relying on tabs.
- DLI publishes no topic weights, so our topic split is an estimate. Several versions of each exam are in use, and some questions ask for more than one answer or the choice that does not apply.
- The master exam adds equipment-size calculations and equipment functions and processes; practice softener sizing and know how Rules 4716 and Statutes 326B.50 to 326B.59 govern the business.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Minnesota Plumbing Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2020 Minnesota Plumbing Code (Minnesota Rules chapter 4714)Essential
DLI supplies the code book (without tabs) in the exam room. It is the 2018 Uniform Plumbing Code with Minnesota amendments.
DLI Plumbing License Examination Guide (April 2022)
DLI's own list of the code chapters and knowledge areas on each plumbing exam, with sample questions and formulas.
Official reference list (as published by the testing agency)
- 2020 Minnesota Plumbing Code, Minnesota Rules chapter 4714 (the 2018 Uniform Plumbing Code with Minnesota amendments), including Rules 4714.0611 (water conditioning equipment). DLI provides the code book, without tabs.
- Minnesota Rules chapter 4716 (water conditioning licensing) and Minnesota Statutes 144, 325 and 326B.50 to 326B.59 (in the DLI laws-and-rules booklet)
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Definitions and General Regulations (Chapters 2 and 3) | 4 | |
| Water Supply: Identification, Unlawful Connections and Prohibited Installation (Chapter 6) | 10 | |
| Water Conditioning Equipment: Application, Manufacture, Labeling and Airgap Discharge | 12 | |
| Sizing of Residential Softeners, Isolation and Bypass | 10 | |
| Pipe Materials and Joints (Chapters 6 and 7) | 8 | |
| Water Conditioning Processes and Equipment Operation | 10 | |
| Minnesota Water Conditioning Licensing and Law (Rules 4716, Statutes 326B.50 to 326B.59) | 11 |
Exam day details
- Administered by the Minnesota Department of Labor and Industry (DLI), which gives its own exams.
- Fee: $50 per personal-license exam (Minn. Stat. 326B.092). Application and license fees are separate.
- 65 questions in 3 hours, open book with DLI-supplied references; 70% to pass.
- Open book with DLI-supplied references: you get the code book (without tabs), the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, notes or electronic devices.
- DLI gives the exam at its St. Paul office and outstate sites, scheduled after DLI approves your application. The time limit is 3 hours; the passing score is 70%.
- Results are mailed in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
- Some questions ask you to pick more than one answer (the question says how many) or the one choice that does not apply. Several versions of each exam are in use.
- DLI's plumbing guide (April 2022) is one checklist for several licenses; the rows marked for water conditioning are mostly Chapter 6 (water supply and water conditioning equipment) and Chapter 7 (pipe materials and joints), plus general regulations and definitions. Not every row is clearly marked, so our topic split is an estimate.
- Rules 4716.0092 says the exam covers plumbing and installation provisions, materials and tools of the trade, water conditioning processes and equipment operation; the master exam adds equipment-size calculations. DLI publishes no topic weights.
- Rules 4714.0611 replaces UPC sections 611.0 to 611.3 and adds 611.5: equipment wetted surfaces, labeling, airgap discharge, connection tubing, residential softener sizing (UPC Table 611.4) and isolation and bypass valves.
Note: DLI's guide marks water conditioning rows within a shared plumbing checklist and publishes no weights, so our topic split is an estimate. Questions follow Rules 4714 and the 2018 UPC chapters 3, 6 and 7, Rules 4716 and Statutes 326B.50 to 326B.59; Statutes 144 and 325 were not on file.
Frequently asked questions
How many questions are on the Minnesota water conditioning master exam?
65 questions in 3 hours; 70% to pass. DLI publishes no topic weights.
Which code is tested?
The 2020 Minnesota Plumbing Code (Rules 4714, the 2018 UPC with Minnesota amendments), especially Chapter 6 and Rules 4714.0611 on water conditioning equipment, plus Rules 4716 and Statutes 326B.
How is the master exam different from the journeyworker exam?
Under Rules 4716.0092 the master exam adds equipment-size calculations and equipment functions and processes.
Free questions with answers
Show all 10 free questions and answers
Rules 4714.0225 adds a definition of water conditioning equipment. Which of these is named in that definition as an example of such equipment?
Answer: Equipment for nitrate and arsenic removal
The definition covers any appliance, appurtenance or fixture designed to treat potable water to alter, modify, add or remove minerals, chemicals or bacteria. Its examples include ion exchange softeners, backwashing and oxidizing filters, cartridge filters, chemical feed cartridges, UV lights, and RO, ultrafiltration, nanofiltration, pH adjustment, nitrate and arsenic removal and activated-carbon adsorption equipment. Expansion tanks, regulators and pumps do not treat water.
Reference: 2020 Minnesota Plumbing Code (Minn. R. ch. 4714), 4714.0225 (UPC 225.0, Water Conditioning Equipment)
A pipe carries reclaimed water from an alternate water source in a building. What background color does the UPC require for identifying it?
Answer: Purple (Pantone 512, 522C or equivalent) with uppercase lettering
UPC 601.3.3 requires alternate water source systems to have a purple background (Pantone 512, 522C, or equivalent) with uppercase lettering marked in the field or at the factory. Yellow is the nonpotable marking and green is potable.
Reference: 2018 Uniform Plumbing Code (adopted by Minn. R. 4714.0050), UPC 601.3.3 (Alternate Water Sources)
A technician proposes connecting a chemical feed line directly to a potable supply pipe without any protective device because the pump is small. Under Rules 4714.0602 (UPC 602.2 as amended), what governs?
Answer: The connection is unlawful unless a backflow prevention device approved for the potential hazard is provided and maintained
Amended UPC 602.2 prohibits connecting domestic water piping to pipes carrying chemicals, liquids, gases or other substances unless a backflow prevention device approved for the potential hazard is provided and maintained in accordance with the code. Pump size, labeling and a manufacturer's claim do not substitute for an approved device.
Reference: 2020 Minnesota Plumbing Code (Minn. R. ch. 4714), 4714.0602, subp. 1 (UPC 602.2, Cross-Contamination)
Which requirement applies to the wetted surface materials of potable water conditioning equipment under Rules 4714.0611?
Answer: They must comply with ANSI/NSF 61, or the equipment must comply with the applicable NSF standards in Table 1701.1
Amended UPC 611.1.1 requires wetted surface materials to comply with ANSI/NSF 61, or the equipment to comply with the applicable NSF standards listed in Table 1701.1 (for example NSF 44 for softeners and NSF 58 for RO). ASSE 1010 covers water hammer arresters, and ASTM D2564 is a solvent cement standard.
Reference: 2020 Minnesota Plumbing Code (Minn. R. ch. 4714), 4714.0611, subp. 1 (UPC 611.1.1)
Using Table 611.4, what connection size is required for a residential softener serving up to 2 bathroom groups?
Answer: 3/4 inch
Table 611.4 (Sizing of Residential Water Softeners) requires a 3/4 in. softener connection for up to 2 bathroom groups and a 1 in. connection for up to 4 bathroom groups. The table is in the base 2018 UPC; Rules 4714.0611 amends 611.0 to 611.3 and adds 611.5, but leaves 611.4 and its table intact.
Reference: 2018 Uniform Plumbing Code (adopted by Minn. R. 4714.0050), UPC 611.4 and Table 611.4
A home has two bathroom groups, a kitchen sink with a dishwasher, and a laundry with a sink and an automatic clothes washer. What connection size does Table 611.4 require, and why?
Answer: 3/4 inch, because the kitchen and laundry fixtures are permitted without an increase in size
Table 611.4 is entered by the number of bathroom groups served, which here is 2, giving 3/4 in. Footnote 1 says a kitchen sink and dishwasher, laundry tray and automatic clothes washer are permitted without additional size increase. Counting those as bathroom groups is the common error.
Reference: 2018 Uniform Plumbing Code (adopted by Minn. R. 4714.0050), UPC Table 611.4, footnote 1
Where may galvanized steel pipe be used for drainage piping under Rules 4714.0701 (UPC 701.2 as amended)?
Answer: Aboveground only, kept at least 6 inches above the ground
Amended UPC 701.2(1) says galvanized wrought-iron and galvanized steel pipe shall not be used underground and shall be kept not less than 6 in. aboveground. A coating, a slab or a gasketed joint does not change that rule.
Reference: 2020 Minnesota Plumbing Code (Minn. R. ch. 4714), 4714.0701 (UPC 701.2(1))
How is the resin in a cation exchange softener recharged during regeneration?
Answer: A salt (sodium or potassium chloride) brine is drawn through the resin, replacing captured hardness ions and sending them to the drain
MDH: during regeneration a highly concentrated salt or potassium solution removes the calcium and magnesium from the resin beads, and the spent solution goes down the drain. Penn State Extension likewise describes the brine being flushed through the resin, carrying the calcium and magnesium ions away. Hot water, compressed air and bleach do not recharge ion exchange resin. The drain discharge must still meet the airgap rule of Rules 4714.0611 (UPC 611.2).
Reference: Minnesota Department of Health, Home Water Softening Frequently Asked Questions (updated 10/03/2022), Regeneration; also Penn State Extension, Water Softening (updated 2025)
Under Rules 4716.0092, what experience qualifies an applicant to take the water conditioning master examination?
Answer: At least 12 months as a licensed water conditioning journeyworker, or 12 months of practical experience as the rule lists it
Subpart 2 of Rules 4716.0092 requires at least 12 months' experience as a licensed water conditioning journeyworker, or at least 12 months of practical experience as listed in subpart 4. The applicant is responsible for verifying the practical experience. Registered unlicensed time alone for 24 months is not what the rule states.
Reference: Minnesota Rules 4716.0090 to 4716.0093, 4716.0092, subp. 2
Which applicant's 1,750 hours meet the aspect minimums of Rules 4716.0092 for the water conditioning master examination?
Answer: Installation 200, servicing 300, planning 250, supervising 250, other work 750
The minimums are installation 200, servicing 300, planning 250 and supervising 250 hours (subp. 4 C(1)); the remaining hours can be any aspect. The first applicant falls short on installation (180), the second on planning (200) and the third on servicing (290). All four options total 1,750 hours, so only the aspect minimums separate them.
Reference: Minnesota Rules 4716.0090 to 4716.0093, 4716.0092, subp. 4, item C(1)
Sources
- DLI Plumbing License Examination Guide (April 2022) (opens in a new tab)
- Minnesota DLI: plumbing license basics (opens in a new tab)
- Minnesota DLI: license exam schedule (opens in a new tab)
Questions last verified November 9, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.