Michigan licensing exam

Michigan Journeyman Electrician Exam: Practice Test & Licensing Guide

The PSI exam for Michigan's journeyman electrician license: 80 questions on grounding, overcurrent protection, wiring methods, services, feeders, motors, load calculations and the Michigan Part 8 rules. Open book, 75% to pass.

Questions
80
Time limit
2.5 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Grounding and Bonding

A ground rod is used as a grounding electrode. How much of its length must be in contact with the soil?

Requirements at a glance

AgencyMichigan LARA, Bureau of Construction Codes; exam by PSI
Exam80 questions, 2 hours 30 minutes, 75% to pass
Books allowedNEC (items based on 2023; factory markings and tabs only, no NEC Handbook), Michigan Electrical Code Rules Part 8, 2016 PA 407 and 1972 PA 230
Fees$100 to PSI per attempt, plus LARA application and license fees
ExperienceAge 20 or older and at least 8,000 hours of electrical work over at least 4 years under the direct supervision of a licensed electrician (MCL 339.5715)
Attempts2 attempts within 1 year, then reapply with the State; 2 failures within 2 years also require a 1-year wait and an approved code course (MCL 339.5715)

Electricians applying to LARA for a Michigan journeyman electrician license, which lets you install electrical wiring under a master electrician.

How to get licensed, step by step

  1. Apply to LARA

    Submit your journeyman electrician application with your experience documentation. LARA approves you before you can pay for the exam.

    Michigan LARA: Bureau of Construction Codes (opens in a new tab)Michigan Legislature: Skilled Trades Regulation Act, 2016 PA 407 (opens in a new tab)

  2. Schedule with PSI

    Follow your approval letter to pay and book. You get 2 attempts within 1 year at $100 each.

    Schedule with PSI (Michigan electrical) (opens in a new tab)PSI: Michigan electrical candidate bulletin (opens in a new tab)

  3. Prepare your books

    Bring a bound NEC with factory markings and tabs only, plus bound copies of Part 8, PA 407 and PA 230. Printed BCC documents need 3 staples and no tabs.

    PSI: Michigan electrical candidate bulletin (opens in a new tab)

How to prepare

  • Michigan adopts the 2023 NEC with Michigan Part 8 amendments (effective 3/12/2024). Exam items are based on the 2023 edition, so tab your book for 2023 articles.
  • Practice finding Table 310.16, Chapter 9 conduit fill tables and Article 430 motor tables quickly; most questions are look-ups plus a calculation.
  • Grounding and bonding, wiring methods, load calculations and motors are the heaviest topics in our estimated weights; the bulletin gives no official weights.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC and Michigan Part 8. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • National Electrical Code (NEC): exam items are based on the 2023 edition; other editions may be used. Factory markings, highlights and factory tabs only. The NEC Handbook is not allowed.
  • Michigan Electrical Code Rules, Part 8 (2023 Part 8 rules adopt the 2023 NEC with Michigan amendments)
  • Skilled Trades Regulation Act, 2016 PA 407
  • State Construction Code Act, 1972 PA 230

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Grounding and Bonding7
Overcurrent Protection6
Wiring Methods and Installations9
Boxes and Cabinets4
Services5
Feeders4
Motors and Motor Controls6
Special Occupancies5
Load Calculations7
Lighting3
Appliances3
Box and Raceway Fill4
Power Limited Circuits3
General Electrical Trade Knowledge4
Electrical Theory4
Skilled Trades Regulation Act, Part 8 Rules and PA 2306

Exam day details

  • Administered by PSI Services for the Michigan Department of Licensing and Regulatory Affairs (LARA), Bureau of Construction Codes.
  • Fee: $100 to PSI per attempt, non-refundable and valid for one year. LARA application and license fees are separate.
  • 80 questions in 2 hours 30 minutes; 75% to pass.
  • The bulletin lists topics but no per-topic weights. Our topic weights are an estimate that adds up to 80.
  • Journeyman, master and sign specialist candidates are limited to 2 attempts within 1 year. After that you must reapply with the State to become eligible again. Under state law, failing the journeyman exam 2 times within 2 years also means waiting at least 1 year and completing a board-approved course before retesting (MCL 339.5715(3)).
  • Reference material must be bound. Material printed from the BCC website must be stapled in 3 places on the left edge in separate documents, with no highlighting, marking or tabs. You may bring a straight edge rule without calculations.
  • The Department (LARA BCC) must approve your application first. It sends a notification letter with instructions to pay and schedule with PSI; only the State decides eligibility.
  • PSI may add up to ten unscored experimental questions; they are not counted in your score and don't take time from the exam.
  • Cancel or reschedule at least 2 days before the appointment to keep your fee; late cancellations and no-shows forfeit it.

Frequently asked questions

What's on the Michigan journeyman electrician exam?

80 questions on grounding and bonding, overcurrent protection, wiring methods, boxes and cabinets, services, feeders, motors and motor controls, special occupancies, load calculations, lighting, appliances, box and raceway fill, power limited circuits, general electrical trade knowledge and electrical theory, plus the Skilled Trades Regulation Act, the Part 8 rules and 1972 PA 230.

Which NEC edition is the Michigan electrician exam based on?

Exam items are based on the 2023 NEC. The bulletin says other editions may be used in the room, but answers follow the 2023 edition and the Michigan Part 8 rules.

How many times can I take the Michigan journeyman electrician exam?

Journeyman candidates are limited to 2 attempts within 1 year. Past that you reapply with the State. Each attempt costs $100 to PSI.

Free questions with answers

Show all 10 free questions and answers
  1. A ground rod is used as a grounding electrode. How much of its length must be in contact with the soil?

    Answer: At least 8 ft

    250.53(A)(4) requires rod and pipe electrodes to have at least 8 ft of length in contact with the soil. Where rock bottom prevents driving, the rod may be driven at an angle up to 45 degrees or buried in a trench at least 30 in. deep.

    Reference: NEC 2023 (NFPA 70), 250.53(A)(4)

  2. A 25-foot feeder tap is protected from physical damage in a raceway and ends at a single circuit breaker. The feeder overcurrent device is rated 300 amperes. What is the minimum ampacity of the tap conductors?

    Answer: 100 amperes

    The 25-ft tap rule in 240.21(B)(2) requires an ampacity of at least one-third of the rating of the overcurrent device protecting the feeder: 300 A / 3 = 100 A. The tap must end in a single breaker or set of fuses that limits the load to the tap ampacity. One-tenth (30 A) is the 10-ft rule.

    Reference: NEC 2023 (NFPA 70), 240.21(B)(2)

  3. Rigid PVC conduit with a 240-volt circuit is buried under a one-family dwelling's driveway, used only for dwelling-related purposes. What is the minimum cover?

    Answer: 18 inches

    Table 300.5(A) has a specific row for one- and two-family dwelling driveways and outdoor parking areas used only for dwelling-related purposes, and 18 in. applies to nonmetallic raceways listed for direct burial. The 24 in. value applies under streets, highways, roads, alleys, driveways and parking lots in general.

    Reference: NEC 2023 (NFPA 70), Table 300.5(A)

  4. A pull box is used for a straight pull of 3 AWG conductors in a 3-inch raceway. What is the minimum length of the box?

    Answer: 24 inches

    For straight pulls of conductors 4 AWG or larger, 314.28(A)(1) requires the box length to be at least eight times the trade size of the largest raceway: 8 x 3 in. = 24 in. The six-times rule (18 in.) is for angle and U pulls.

    Reference: NEC 2023 (NFPA 70), 314.28(A)(1)

  5. Overhead service conductors (not exceeding 300 volts to ground) cross a driveway at a one-family dwelling. What is the minimum clearance above final grade?

    Answer: 12 feet

    230.24(B)(2) requires 12 ft over residential property and driveways and commercial areas not subject to truck traffic where the voltage does not exceed 300 V to ground. 10 ft is limited to pedestrian-only areas and entrance points with cabled messenger conductors, and 18 ft applies over public streets and roads.

    Reference: NEC 2023 (NFPA 70), 230.24(B)(2)

  6. The informational note to 215.2 recommends sizing feeders so that the voltage drop at the farthest outlet does not exceed what percentage, with a combined feeder and branch circuit total of 5 percent?

    Answer: 3 percent

    215.2(A) Informational Note No. 2 recommends sizing feeder conductors for a voltage drop of not more than 3 percent at the farthest outlet, with a total of not more than 5 percent for the feeder and branch circuit combined. It is a recommendation and not a mandatory rule.

    Reference: NEC 2023 (NFPA 70), 215.2(A), Informational Note No. 2

  7. A 10-horsepower, 230-volt, three-phase induction motor has a Table 430.250 full-load current of 28 amperes. What is the minimum ampacity of the branch-circuit conductors for a single continuous-duty motor?

    Answer: 35 amperes

    430.22 requires the conductors to have an ampacity of at least 125 percent of the full-load current: 28 x 1.25 = 35 A. Using 28 A ignores the 125 percent factor, 49 A uses 175 percent, and 70 A is the 250 percent used for breaker sizing.

    Reference: NEC 2023 (NFPA 70), 430.22

  8. A dwelling has a general lighting load of 5,400 VA (1,800 sq ft), 3,000 VA of small-appliance loads and 1,500 VA of laundry load. Applying Table 220.45, what is the demand load of these three items combined?

    Answer: 5,415 VA

    Total = 5,400 + 3,000 + 1,500 = 9,900 VA. Table 220.45 allows the first 3,000 VA at 100 percent and 3,001 to 120,000 VA at 35 percent: 3,000 + (6,900 x 0.35 = 2,415) = 5,415 VA. Applying 35 percent to the whole amount gives 3,465 VA, which is too low.

    Reference: NEC 2023 (NFPA 70), Table 220.45 and 220.52

  9. For a permanently installed swimming pool, what is the required location of the receptacle on a general-purpose branch circuit?

    Answer: Not less than 6 feet and not more than 20 feet from the inside wall of the pool

    680.22(A)(1) requires at least one 125-volt, 15- or 20-ampere receptacle on a general-purpose branch circuit not less than 6 ft and not more than 20 ft from the inside wall of the pool, mounted no more than 6 ft 6 in. above the deck or grade. All receptacles within 20 ft also require GFCI protection.

    Reference: NEC 2023 (NFPA 70), 680.22(A)(1) and (A)(4)

  10. Under MCL 339.5715 (Skilled Trades Regulation Act), what are the age and experience requirements for an electrical journeyman's license?

    Answer: At least 20 years old with 8,000 hours of experience over at least 4 years

    MCL 339.5715(1)(a) requires an applicant to be at least 20 years old with at least 8,000 hours of experience over a period of at least 4 years, under the direct supervision of a licensed individual. The 22 years and 12,000 hours listed is the master electrician requirement in MCL 339.5713.

    Reference: 2016 PA 407 (Skilled Trades Regulation Act), MCL 339.5715, MCL 339.5715(1)(a)

Sources

Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.