Requirements at a glance
| Agency | Michigan LARA, Bureau of Construction Codes; exam by PSI |
|---|---|
| Exam | 36 questions, 1 hour 30 minutes, 75% to pass |
| Books allowed | NEC (items based on 2023; factory markings and tabs only, no NEC Handbook), Michigan Electrical Code Rules Part 8, 2016 PA 407 and 1972 PA 230 |
| Fees | $100 to PSI per attempt, plus LARA application and license fees |
| Qualification | Age 20 or older and NICET certification as an associate engineering technician, level II, or an equivalent fire alarm certification the board accepts (MCL 339.5721) |
| Attempts | Unlimited attempts within 1 year, paying the fee each time |
Fire alarm technicians applying to LARA for a Michigan fire alarm specialty technician license.
Official links
How to get licensed, step by step
Apply to LARA
Submit your fire alarm specialty technician application with your experience documentation. LARA approves you before you can pay for the exam.
Michigan LARA: Bureau of Construction Codes (opens in a new tab)Michigan Legislature: Skilled Trades Regulation Act, 2016 PA 407 (opens in a new tab)
Schedule with PSI
Follow your approval letter to pay and book. Retests are unlimited within the year at $100 each.
Schedule with PSI (Michigan electrical) (opens in a new tab)PSI: Michigan electrical candidate bulletin (opens in a new tab)
Prepare your books
Bring a bound NEC with factory markings and tabs only, plus bound copies of Part 8, PA 407 and PA 230. Printed BCC documents need 3 staples and no tabs.
PSI: Michigan electrical candidate bulletin (opens in a new tab)
How to prepare
- Michigan adopts the 2023 NEC with Michigan Part 8 amendments (effective 3/12/2024). Exam items are based on the 2023 edition, so tab your book for 2023 articles.
- Power limited circuits (NEC Article 760 and Chapter 7) carry the most weight in our estimate; know the 760 conductor and separation rules.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC and Michigan Part 8. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 editionEssential
Exam items are based on the 2023 NEC; Michigan adopts it with Part 8 amendments. Factory markings and tabs only; the NEC Handbook is not allowed.
Michigan Electrical Code Rules, Part 8Essential
Free from LARA. The Michigan amendments to the NEC; named in the electrical bulletin and allowed in the room (bound, 3 staples, no tabs).
LARA: Michigan code books and adopted codes (opens in a new tab)
Skilled Trades Regulation Act, 2016 PA 407
Free online from the Michigan Legislature. The licensing law for plumbers and mechanical contractors; shown on screen in the plumbing exams.
Stille-DeRossett-Hale Single State Construction Code Act, 1972 PA 230
Free online from the Michigan Legislature. Permits, inspections and code enforcement; law questions draw on it.
Official reference list (as published by the testing agency)
- National Electrical Code (NEC): exam items are based on the 2023 edition; other editions may be used. Factory markings, highlights and factory tabs only. The NEC Handbook is not allowed.
- Michigan Electrical Code Rules, Part 8 (2023 Part 8 rules adopt the 2023 NEC with Michigan amendments)
- Skilled Trades Regulation Act, 2016 PA 407
- State Construction Code Act, 1972 PA 230
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Grounding and Bonding | 3 | |
| Overcurrent Protection | 2 | |
| Wiring Methods and Installations | 5 | |
| Boxes and Cabinets | 2 | |
| Special Occupancies | 3 | |
| Load Calculations | 3 | |
| Box and Raceway Fill | 2 | |
| Power Limited Circuits | 6 | |
| General Electrical Trade Knowledge | 3 | |
| Electrical Theory | 2 | |
| Skilled Trades Regulation Act, Part 8 Rules and PA 230 (fire alarm systems) | 5 |
Exam day details
- Administered by PSI Services for the Michigan Department of Licensing and Regulatory Affairs (LARA), Bureau of Construction Codes.
- Fee: $100 to PSI per attempt, non-refundable and valid for one year. LARA application and license fees are separate.
- 36 questions in 1 hour 30 minutes; 75% to pass.
- The bulletin lists topics but no per-topic weights. Our topic weights are an estimate that adds up to 36.
- Fire alarm specialty technician candidates have unlimited attempts within 1 year, paying the exam fee each time.
- Besides the exam, the license requires NICET certification as an associate engineering technician, level II, or an equivalent certification the board accepts (MCL 339.5721).
- Reference material must be bound. Material printed from the BCC website must be stapled in 3 places on the left edge in separate documents, with no highlighting, marking or tabs. You may bring a straight edge rule without calculations.
- The Department (LARA BCC) must approve your application first. It sends a notification letter with instructions to pay and schedule with PSI; only the State decides eligibility.
- PSI may add up to ten unscored experimental questions; they are not counted in your score and don't take time from the exam.
- Cancel or reschedule at least 2 days before the appointment to keep your fee; late cancellations and no-shows forfeit it.
Frequently asked questions
What's on the Michigan fire alarm specialty technician exam?
36 questions on grounding and bonding, overcurrent protection, wiring methods, boxes and cabinets, special occupancies, load calculations, box and raceway fill, power limited circuits, general electrical trade knowledge and electrical theory, plus the Skilled Trades Regulation Act, Part 8 rules and PA 230 as they relate to fire alarm systems.
Do I need NICET certification?
The license requires certification by NICET as an associate engineering technician, level II, or an equivalent fire alarm certification the board accepts (MCL 339.5721). The exam is a separate requirement.
How many times can I retake it?
Fire alarm specialty technician candidates have unlimited attempts within 1 year, paying $100 each time.
Free questions with answers
Show all 10 free questions and answers
What does 760.121(B)(5) allow for the fire alarm branch-circuit disconnecting means?
Answer: It may be secured in the "on" position
760.121(B)(5) permits the fire alarm branch-circuit disconnect to be secured in the on position, which keeps a person from switching the system off accidentally. The disconnect is still required; an internal battery does not replace it, and the circuit must not be a cord-and-plug connection to a general-use receptacle.
Reference: NEC 2023 (NFPA 70), 760.121(B)(5)
A single ground rod is the only electrode installed at a building. Which condition lets the installer omit a supplemental electrode under the exception to 250.53(A)(2)?
Answer: The single rod has a resistance to earth of 25 ohms or less
250.53(A)(2) requires a single rod, pipe, or plate electrode to be supplemented by another electrode. The exception waives the supplement when the single electrode has a resistance to earth of 25 ohms or less. Length, diameter, and plating do not satisfy the exception.
Reference: NEC 2023 (NFPA 70), 250.53(A)(2), Exception
A single-phase transformer with a 2-wire secondary supplies a 12 AWG copper NPLFA circuit rated at an ampacity of 20 A. The transformer is 240 V primary and 120 V secondary. Under Exception No. 2 to 760.45, what is the maximum primary protection that can protect the secondary conductors?
Answer: 10 amperes
Exception No. 2 limits primary protection to the secondary conductor ampacity multiplied by the secondary-to-primary voltage ratio: 20 A x (120 V / 240 V) = 20 x 0.5 = 10 A. Using 20 A forgets the ratio and 40 A inverts it. The exception only works for a single-phase transformer with a 2-wire (single-voltage) secondary and protection per 450.3.
Reference: NEC 2023 (NFPA 70), 760.45, Exception No. 2
What conductor material is permitted for fire alarm circuits under Article 760?
Answer: Solid or stranded copper only
760.49(A) and (C) say that only copper conductors are permitted to be used for fire alarm systems (solid or stranded), and 760.130(A) repeats the copper requirement for PLFA circuits. Aluminum is not allowed, whatever the size or the wiring method.
Reference: NEC 2023 (NFPA 70), 760.49(A) and (C)
A broken gypsum surface around a flush-mounted fire alarm box must be repaired so that no gap at the edge of the box exceeds what dimension?
Answer: 3 mm (1/8 in.)
314.21 requires noncombustible surfaces that are broken or incomplete around boxes with a flush-type cover or faceplate to be repaired so there are no gaps or open spaces greater than 3 mm (1/8 in.) at the edge of the box.
Reference: NEC 2023 (NFPA 70), 314.21
In a hospital essential electrical system, which branch supplies the fire alarm system?
Answer: The life safety branch
517.33(C) lists alarm and alerting systems, including fire alarm systems, among the functions connected to the life safety branch. The life safety branch is limited to circuits essential to life safety.
Reference: NEC 2023 (NFPA 70), 517.33(C)(1)
A 24-volt, 40 VA listed transformer supplies a power-limited fire alarm circuit. What is the maximum continuous load current available on the secondary?
Answer: About 1.67 amperes
Current = VA / volts = 40 / 24 = 1.67 A on the secondary. The primary current at 120 V would be 40 / 120 = 0.33 A, which is a common mix-up.
Reference: General practice, Power relationship, VA = V x I
A 4 in. square x 1-1/2 in. deep metal box (21.0 cu in.) contains six 14 AWG conductors that terminate in the box, two 14 AWG equipment grounding conductors, one device on a yoke, and internal cable clamps. Using Table 314.16(B)(1) (2.00 cu in. for 14 AWG), what is the total box fill?
Answer: 20.0 cu in.
Conductors: 6 x 2.0 = 12.0. Equipment grounding conductors together: one allowance of 2.0. Device yoke: double allowance, 2 x 2.0 = 4.0. Clamps: one allowance of 2.0. Total = 12 + 2 + 4 + 2 = 20.0 cu in., which fits the 21.0 cu in. box. 18.0 omits the clamps, 22.0 counts each EGC separately, and 16.0 gives the device only a single allowance and omits clamps.
Reference: NEC 2023 (NFPA 70), 314.16(B)(1) through (B)(5), Table 314.16(B)(1)
What is the ratio of fire alarm specialty technicians to registered fire alarm specialty apprentice technicians on a jobsite?
Answer: One technician to two registered apprentices
MCL 339.5723(3) sets the ratio at 1 fire alarm specialty technician to 2 registered fire alarm specialty apprentice technicians, and the department or enforcing agency enforces the ratio on a jobsite basis.
Reference: 2016 PA 407 (Skilled Trades Regulation Act), MCL 339.5723(3)
What minimum depth of working space is required in front of a 120-volt panel (Condition 1) under Table 110.26(A)(1)?
Answer: 900 mm (3 ft)
Table 110.26(A)(1) requires 900 mm (3 ft) for 0 to 150 volts to ground in Conditions 1, 2, and 3. The 1.0 m (3 ft 6 in.) and 1.2 m (4 ft) figures are for 151 to 600 volts under Conditions 2 and 3.
Reference: NEC 2023 (NFPA 70), 110.26(A)(1), Table 110.26(A)(1)
Sources
- PSI: Michigan Electrical Examinations Candidate Information Bulletin (effective 8/20/2026) (opens in a new tab)
- Schedule with PSI (Michigan electrical) (opens in a new tab)
- Michigan Legislature: Skilled Trades Regulation Act, 2016 PA 407 (opens in a new tab)
- Michigan LARA: Bureau of Construction Codes (opens in a new tab)
- LARA: PSI examinations for the Bureau of Construction Codes (opens in a new tab)
- LARA: Michigan code books and adopted codes (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.