Massachusetts licensing exam

Massachusetts Construction Supervisor License (CSL) Exam: Practice Test & Licensing Guide

The Massachusetts Unrestricted Construction Supervisor License exam: 75 questions in 240 minutes on the state building code (780 CMR 10th edition with the 2021 IBC, IRC and IECC), stretch energy codes, 521 CMR accessibility and OSHA 1926. Open book, 70% (53 correct) to pass.

Questions
75
Time limit
4 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Building Construction Knowledge

Under the Massachusetts-amended residential code, what must every dwelling unit have for exits from the living space to the outside?

Requirements at a glance

AgencyBoard of Building Regulations and Standards (BBRS), Division of Occupational Licensure; exam by PSI
LicenseConstruction Supervisor License: Unrestricted (buildings under 35,000 cubic feet and one- and two-family dwellings), Restricted (one- and two-family dwellings only) or a specialty category
EligibilityAge 18 and 3 years of building construction or design experience (up to 2 years from education)
FormatUnrestricted: 75 questions, 240 minutes. Restricted: 60 questions, 240 minutes. Open book, 70% to pass.
Fees$75 exam fee and $23 application fee to PSI (not refundable), plus the state license fee

People who directly supervise construction, reconstruction, alteration, repair, removal or demolition of buildings in Massachusetts. The Unrestricted license covers buildings with less than 35,000 cubic feet of enclosed space, one- and two-family dwellings and their accessory buildings of any size, farm buildings, and retaining walls under 10 feet. The Restricted license covers only one- and two-family dwellings and their accessory buildings. Masonry, roof covering, window and siding, solid fuel burning appliance, demolition and insulation are separate specialty licenses with their own exams.

How to get licensed, step by step

  1. Apply through PSI

    Create a PSI account, choose your exam and upload proof of 3 years of experience (W-2, 1099 or Schedule C forms, or a letter of attestation) with a notarized signature. Review takes up to 2 weeks.

    Schedule with PSI (Massachusetts construction supervisor) (opens in a new tab)

  2. Schedule with PSI

    Once approved, pay and schedule online or at (855) 746-8173. Your approval stays on file for 2 years.

    Schedule with PSI (Massachusetts construction supervisor) (opens in a new tab)

  3. Pass at 70%

    Bring your own tabbed copies of the references in the handbook. Results come right after the exam, and retakes are unlimited.

    Construction Supervisor Candidate Handbook (February 2026) (opens in a new tab)

  4. Apply for the license

    Send the license application and fee to the Division of Occupational Licensure within one year of passing.

    Board of Building Regulations and Standards (BBRS) (opens in a new tab)

How to prepare

  • Associated trades (finishes, windows and doors) and general building construction are 8 questions each, the largest sections of the Unrestricted outline. Concrete and masonry is 7.
  • Plan reading and estimating (6) and OSHA safety (6) together are 12 of 75. Practice reading plans and doing quantity takeoffs, and tab 29 CFR 1926 for fall protection, scaffolds, ladders and excavations.
  • Administrative responsibilities (5) come from 780 CMR: know permits, inspections and the construction supervisor's duties.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from 780 CMR and the 2021 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • Massachusetts State Building Code, 780 CMR, 10th edition: Massachusetts amendments to the building code base volume (commercial) and to the residential code for one- and two-family dwellings
  • 2021 International Building Code (IBC)
  • 2021 International Residential Code (IRC)
  • 2021 International Energy Conservation Code (IECC), with the Massachusetts Residential and Commercial Stretch Codes (225 CMR, 10th edition)
  • 521 CMR, Architectural Access Board Rules and Regulations (2006)
  • OSHA 29 CFR 1926 (Construction), latest amendments, or PSI's 29 CFR 1926 selections

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Administrative Responsibilities (780 CMR)5
Plan Reading and Estimating6
General Building Construction Knowledge8
Energy Efficiency5
Accessibility3
Sitework and Foundations5
Concrete and Masonry7
Moisture Intrusion/Protection4
Structural Framing (Steel and Wood)6
Roofing/Exterior Walls6
Associated Trades (Finishes, Windows and Doors)8
Interior Environment (Mechanical and Ventilation)3
Fire Protection3
Safety (OSHA)6

Exam day details

  • Administered by PSI Services for the Massachusetts Board of Building Regulations and Standards (BBRS), Division of Occupational Licensure.
  • Fee: $75 exam fee and $23 application fee to PSI, neither refundable. The state license fee is separate.
  • Our practice bank follows the Unrestricted exam: 75 scored questions in 240 minutes, 53 correct (70%) to pass. The Restricted (one- and two-family) exam is 60 questions in 240 minutes, 42 to pass; its outline drops general building construction knowledge and accessibility, and its references are the IRC, IECC and residential amendments plus OSHA.
  • PSI may add 4 to 7 unscored trial questions, which do not count against your time. You get your result at the test center as soon as you finish.
  • Open book: bring your own copies of the references. They may be highlighted, underlined, annotated and indexed beforehand with permanent tabs only (no Post-it notes), but you may not write in them during the exam or bring loose papers. PSI provides an on-screen calculator; a silent, non-programmable calculator is also allowed.
  • To qualify you must be 18 and have 3 years (36 months full time within the last 10 years) of building construction or design experience, documented with W-2, 1099 or Schedule C forms or a letter of attestation. A vocational program or college degree counts as 1 year, a related architecture, engineering or technology degree as 2 (2 years at most from education). Union membership alone does not count.
  • Apply through PSI and upload your documents; review takes up to 2 weeks and the approval stays on file for 2 years. Retakes are unlimited, and depending on space you may retest within two business days.
  • After you pass, send the license application and fee to the Division of Occupational Licensure within one year.

Frequently asked questions

What is the Massachusetts Construction Supervisor License?

The BBRS license for people who directly supervise building construction, alteration, repair or demolition. Unrestricted covers buildings under 35,000 cubic feet and one- and two-family dwellings of any size; Restricted covers only one- and two-family dwellings.

How many questions are on the CSL exam?

The Unrestricted exam has 75 scored questions in 240 minutes, and you need 53 correct (70%). The Restricted exam has 60 questions in 240 minutes (42 to pass). The specialty exams have 30 to 50 questions.

Is the CSL exam open book?

Yes. Bring your own copies of the 2021 IBC, IRC and IECC, the 10th edition Massachusetts amendments (780 CMR), the stretch codes (225 CMR), 521 CMR and OSHA 29 CFR 1926. Permanent tabs and notes written beforehand are allowed; Post-it notes and loose papers are not.

Which code edition is tested?

The February 2026 handbook bases the questions on the 2021 International codes with the 10th edition Massachusetts amendments (780 CMR) and 521 CMR (2006). You may bring any edition of those books to the test center.

Free questions with answers

Show all 10 free questions and answers
  1. Under the Massachusetts-amended residential code, what must every dwelling unit have for exits from the living space to the outside?

    Answer: A primary and a secondary egress door, remote from each other

    R311.2 in the Massachusetts text requires a primary and a secondary egress door for each dwelling unit, located as remote as possible from each other. The primary is side-hinged with 32 inches clear; the secondary may be side-hinged or sliding with 28 inches clear (side-hinged). The unamended IRC requires only one egress door, so this is a Massachusetts point.

    Reference: 780 CMR (MA Residential Code, 10th ed.; 2021 IRC with MA amendments), R311.2

  2. Which wood-frame wall insulation option is listed as complying in Climate Zone 5 in the R-value alternative table?

    Answer: R-20 cavity insulation plus R-5 continuous insulation

    Table N1102.1.3 lists R-30, or 20 & 5ci, or 13 & 10ci, or 0 & 20ci for wood-frame walls in Zone 5. R-13 plus R-5ci falls short; R-13 needs R-10 continuous insulation to comply.

    Reference: 780 CMR (MA Residential Code, 10th ed.; 2021 IRC Chapter 11 with MA amendments), Table N1102.1.3 (R402.1.3)

  3. What frost line depth does the Massachusetts residential code list in Table R301.2 for footing design?

    Answer: 48 inches

    The Massachusetts version of Table R301.2 lists the frost line depth as 48 inches, and R403.1.4.1 requires foundations to extend below the frost line unless protected another way (frost-protected shallow foundation, ASCE 32, or solid rock).

    Reference: 780 CMR (MA Residential Code, 10th ed.; 2021 IRC with MA amendments), Table R301.2; R403.1.4.1

  4. A 6-inch-thick residential slab-on-ground is to be cut with control joints. What is the minimum control joint depth, and the maximum spacing in each direction, if the slab is not reinforced as in Table R506.1.1?

    Answer: 1.5 inches deep, spaced at most 30 feet apart

    R506.1.1 requires control joints at least one quarter of the slab thickness deep but not less than 1 inch: 6 in / 4 = 1.5 in. Joints may be spaced no more than 30 feet in each direction. A 4-inch slab would need only the 1-inch minimum.

    Reference: 780 CMR (MA Residential Code, 10th ed.; 2021 IRC with MA amendments), R506.1.1

  5. Joists exceeding what nominal size require lateral support by solid blocking, diagonal bridging or a continuous strip, and at what maximum spacing?

    Answer: Larger than 2x12, at intervals not over 8 feet

    R502.7.1 requires bridging for joists exceeding a nominal 2x12, using solid blocking, diagonal bridging or a continuous 1x3 strip across the bottom, at intervals not exceeding 8 feet. Joist ends must also be laterally supported (R502.7).

    Reference: 780 CMR (MA Residential Code, 10th ed.; 2021 IRC with MA amendments), R502.7.1

  6. What is the minimum number of fasteners per strip asphalt shingle, unless the manufacturer requires more?

    Answer: Four

    R905.2.6 requires the number of fasteners in the manufacturer's approved installation instructions but not fewer than four per strip shingle or two per individual shingle.

    Reference: 780 CMR (MA Residential Code, 10th ed.; 2021 IRC with MA amendments), R905.2.6

  7. Under the residential code, a door landing at a required egress door may be no more than how far below the top of the threshold (when no exception applies)?

    Answer: 1 1/2 inches

    R311.3.1 requires landings or finished floors at the required egress door to be not more than 1-1/2 inches lower than the top of the threshold. The exterior-side exception of 8-1/4 inches applies only where the door does not swing over the landing.

    Reference: 780 CMR (MA Residential Code, 10th ed.; 2021 IRC with MA amendments), R311.3.1

  8. What are the required top rail height for a guardrail system and the minimum force the system must withstand at the top edge?

    Answer: 42 inches plus or minus 3 inches, and 200 pounds

    29 CFR 1926.502(b)(1) sets the top edge height at 42 inches plus or minus 3 inches, and (b)(3) requires guardrails to withstand at least 200 pounds applied within 2 inches of the top edge in any outward or downward direction. Midrails must withstand 150 pounds (b)(5).

    Reference: 29 CFR 1926 (OSHA Construction Standards), 29 CFR 1926.502(b)(1), (b)(3)

  9. Continuous concrete footings 16 inches wide and 8 inches thick run under all four walls of a 30 ft by 40 ft house (centerline perimeter 140 ft; ignore corner overlap). How many cubic yards of concrete are needed, to the nearest tenth?

    Answer: 4.6 cubic yards

    Volume = 140 x (16/12) x (8/12) = 124.4 cubic feet; 124.4 / 27 = 4.6 cubic yards. 3.5 uses a 12-inch width, 6.9 uses a 12-inch thickness, and 9.2 doubles the correct result. The footing is not smaller than the 12-inch width and 6-inch depth minimums in R403.1.1.

    Reference: 2021 International Residential Code (IRC), as adopted in 780 CMR 10th ed., R403.1.1 Minimum Size

  10. A building permit was issued 170 days ago, but the owner has not yet started work on site. What does 780 CMR 105.5 require to keep the permit from becoming invalid?

    Answer: A written extension request made before the 180-day period ends, showing justifiable cause

    A permit becomes invalid if work is not commenced within 180 days of issuance (or is suspended or abandoned for 180 days). The building official may grant extensions of up to 180 days each, but the request must be in writing, made before the 180-day date, and show justifiable cause.

    Reference: 780 CMR 10th ed. (as amended eff. 10/11/2024; mass.gov text 4/29/2025), 105.5 Expiration

Sources

Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.