Requirements at a glance
| Agency | Maryland State Board of Plumbing; exam by PSI |
|---|---|
| Experience | 2 years and at least 3,750 hours as a licensed journey plumber after 4 years and 7,500 hours of apprentice work, plus an approved 32-hour backflow prevention device testing course. |
| Exam | 100 questions, 4 hours, 70% to pass |
| Books allowed | 2018 IPC and IFGC, Mathematics for Plumbers and Pipefitters (8th edition), a backflow text and 29 CFR 1926 |
| Fees | $65 to PSI, plus Board application and license fees |
Plumbers applying for a Maryland master plumber/gas fitter license from the State Board of Plumbing, usually after 2 years and 3,750 hours as a journey plumber and a 32-hour backflow course.
Official links
How to get licensed, step by step
Confirm you qualify
2 years and at least 3,750 hours as a licensed journey plumber after 4 years and 7,500 hours of apprentice work, plus an approved 32-hour backflow prevention device testing course.
Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)Maryland Code (General Assembly) (opens in a new tab)
Apply through PSI
Submit the exam application online at the PSI site below (mailed or faxed applications are returned). PSI and the Board review your documents, then email you how to pay and schedule.
Schedule with PSI (plumbers and gas fitters) (opens in a new tab)
Pass the open-book exam
Exam fees are non-refundable and non-transferable. The bulletin lists no waiting period between attempts; confirm with PSI.
Schedule with PSI (plumbers and gas fitters) (opens in a new tab)
Apply for the license
After you pass, the Board sends you the license application. Pay the license fee and file any required insurance.
Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)
How to prepare
- Tab your books before exam day: permanent plastic tabs (Avery Swift or Redi-Tag), highlighting and underlining are allowed; Post-It flags and writing in the book are not.
- Gas appliances and piping is 40 of the 100 questions: tab IFGC Chapters 3 to 7 and the pipe sizing tables, and practice sizing from the tables.
- Backflow prevention is 10 questions. Know the IPC Section 608 assembly requirements and any standard backflow text.
- No handheld calculator is allowed in the room, so practice the plumbing math by hand.
- The bulletin (8/10/2026) still lists the 2018 IPC and IFGC while the state code is now the 2024 edition; check the current bulletin before buying books.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 IPC and the 2018 IFGC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 International Plumbing Code (IPC)Essential
Allowed in the exam room. Drain, waste, vent, water supply and backflow questions.
2018 International Fuel Gas Code (IFGC)Essential
Allowed in the exam room. Gas appliances and piping are 40 of the 100 plumber questions.
Mathematics for Plumbers and Pipefitters, Lee Smith, 8th Edition (2013)
Allowed in the exam room. Offsets, pipe sizing and volume math for the 7 math questions.
29 CFR 1926 (OSHA Construction Standards), sections on your reference list
Trenching, scaffolds, fall protection and ladders. Print just the listed sections.
Official reference list (as published by the testing agency)
- International Plumbing Code (IPC), 2018 edition (allowed in the exam room)
- International Fuel Gas Code (IFGC), 2018 edition (allowed in the exam room)
- Mathematics for Plumbers and Pipefitters, Lee Smith, 8th Edition, 2013 (allowed in the exam room)
- Any standard backflow text (allowed in the exam room)
- 29 CFR Part 1926 (OSHA construction standards), with latest amendments, or the PSI selections (allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Plumbing Fundamentals and Safety | 5 | |
| Materials, Uses, and Specifications | 6 | |
| Traps, Interceptors, and Backwater Valves | 4 | |
| Plumbing Fixtures, Fixture Fittings, and Plumbing Appliances | 4 | |
| Water Supply Systems | 8 | |
| Backflow Prevention | 10 | |
| Drain, Waste, and Vent Systems | 13 | |
| Special Topics | 3 | |
| Gas Appliances and Piping | 40 | |
| Plumbing Mathematics | 7 |
Exam day details
- Administered by PSI Services for the Maryland State Board of Plumbing.
- Fee: $65 to PSI per exam. Board application and license fees are separate.
- 100 questions in 4 hours; 70 correct (70%) to pass.
- Edition note: The PSI bulletin (8/10/2026) lists the 2018 IPC and IFGC. The Maryland codes moved to the 2024 editions on November 24, 2025, and the Board has said PSI will remove questions to comply with the 2024 codes. Check the current bulletin before you buy books.
- Open book: you may bring only the listed references (none are provided), which you may index, highlight and underline but not write in. Study guides are not allowed.
- Handheld calculators are not allowed in the exam room. Plan to work the plumbing mathematics section by hand.
- PSI adds one to ten unscored experimental items, and the time spent on them counts against your exam time.
- The Board approves your experience first; every master applicant also needs an approved 32-hour backflow prevention device testing course.
- If a code and a trade reference disagree, the code, law or regulation overrides the other sources. State-specific law overrides national law.
Frequently asked questions
What's on the Maryland master plumber exam?
100 questions: gas appliances and piping 40, drain, waste and vent systems 13, backflow prevention 10, water supply systems 8, plumbing mathematics 7, materials 6, plumbing fundamentals and safety 5, traps and backwater valves 4, fixtures 4 and special topics 3.
Which code editions does the Maryland plumbing exam use?
The PSI bulletin lists the 2018 IPC and 2018 IFGC. Maryland has moved to the 2024 codes, so check the current bulletin for your test date.
Can I use a calculator on the Maryland plumber exam?
The bulletin bans handheld calculators in the exam room, so practice the math by hand with Mathematics for Plumbers and Pipefitters.
Free questions with answers
Show all 10 free questions and answers
A new natural gas piping system in a house will operate at a proposed maximum working pressure of 14 inches of water column (about 0.5 psig). What is the minimum pressure the system must be tested at before it is accepted?
Answer: 3 psig, because the test pressure may never be lower than 3 psig
Section 406.4.1 requires a test pressure of at least 1-1/2 times the proposed maximum working pressure but not less than 3 psig regardless of design pressure. 1.5 x 0.5 psig = 0.75 psig, so the 3 psig floor controls. The 5 psig figure is the inside-building operating limit in 402.7, not a test requirement.
Reference: 2018 International Fuel Gas Code (Maryland adoption), 406.4.1
A lavatory faucet has an effective opening of 1/2 inch and is installed away from any wall. What is the minimum air gap from the outlet to the flood level rim?
Answer: 1 inch
Table 608.16.1 requires 1 inch for lavatories and other fixtures with effective openings not greater than 1/2 inch when away from a wall (1-1/2 inches when close to a wall). Sinks with openings up to 3/4 inch need 1-1/2 inches away from a wall.
Reference: 2018 International Plumbing Code (Maryland adoption), Table 608.16.1
Using Table 704.1, what is the minimum slope for a horizontal 3-inch drainage pipe?
Answer: 1/8 inch per foot
Table 704.1 requires 1/4 inch per foot for pipe 2-1/2 inches or smaller, 1/8 inch per foot for 3 to 6 inch pipe, and 1/16 inch per foot for 8 inch and larger. Piping upstream of a grease interceptor must have at least 1/4 inch per foot.
Reference: 2018 International Plumbing Code (Maryland adoption), 704.1, Table 704.1
A commercial kitchen interceptor has a rated flow-through of 12 gpm. Using Table 1003.3.5.1, what grease retention capacity is required?
Answer: 24 pounds
Table 1003.3.5.1 gives a retention capacity equal to twice the flow-through rating in gpm: 12 gpm x 2 = 24 pounds (for example 10 gpm = 20 lb, 18 gpm = 36 lb). Ratings above 100 gpm are also doubled.
Reference: 2018 International Plumbing Code (Maryland adoption), 1003.3.5.1, Table 1003.3.5.1
Exterior water supply piping is being buried in a cold climate. What minimum burial depth does Section 305.4 require?
Answer: 6 inches below the frost line and at least 12 inches below grade
Section 305.4 requires exterior water supply piping to be installed not less than 6 inches below the frost line and not less than 12 inches below grade, and pipes in attics, crawl spaces or outside walls to be protected from freezing by insulation or heat.
Reference: 2018 International Plumbing Code (Maryland adoption), 305.4
Where must pipe-joint compound or tape be applied on a threaded copper water pipe joint?
Answer: On the male threads only
Section 605.12.4 requires threads to conform to ASME B1.20.1 and pipe-joint compound or tape to be applied on the male threads only, so that excess material does not enter the pipe.
Reference: 2018 International Plumbing Code (Maryland adoption), 605.12.4
What is the minimum distance from the centerline of a water closet to a side wall or partition?
Answer: 15 inches
Section 405.3.1 requires a water closet, urinal, lavatory or bidet to be at least 15 inches from its center to any side wall or obstruction, with 30 inches center to center between adjacent fixtures and at least 21 inches clear in front.
Reference: 2018 International Plumbing Code (Maryland adoption), 405.3.1
Each water tank inlet must have an air gap above the overflow when filled from the potable supply. What minimum air gap does Section 606.5.6 specify?
Answer: 4 inches
Section 606.5.6 requires the potable inlet to a gravity tank to be controlled by a fill valve or automatic supply valve and to terminate with an air gap of at least 4 inches above the overflow.
Reference: 2018 International Plumbing Code (Maryland adoption), 606.5.6
What are the minimum depth of a water heater safety pan and the minimum size of its drain?
Answer: 1-1/2 inches deep with a 3/4 inch drain
Section 504.7.1 requires the pan to be at least 1-1/2 inches deep, large enough to catch all dripping, and drained by an indirect waste pipe at least 3/4 inch in diameter. A plastic pan may not be used under a gas-fired water heater (504.7).
Reference: 2018 International Plumbing Code (Maryland adoption), 504.7, 504.7.1
A section of drain is water tested with a 30 foot head of water. Using 0.433 psi per foot of head, what pressure is at the bottom?
Answer: 13 psi
Pressure = head x 0.433 psi per foot = 30 x 0.433 = 12.99, about 13 psi. Dividing by 0.433 (30 / 0.433 = 69) or using the head in feet as psi are common mistakes.
Reference: 2018 International Plumbing Code (Maryland adoption), 312.2
Sources
- PSI: Maryland Plumbing and Gas Fitter Examinations Candidate Information Bulletin (8/10/2026) (opens in a new tab)
- Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)
- Maryland General Assembly: Maryland Code (statutes) (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.