Requirements at a glance
| Agency | Maryland State Board of Plumbing; exam by PSI |
|---|---|
| Experience | 4 years and at least 7,500 hours as a licensed apprentice plumber under a licensed master plumber; up to 1,500 hours of approved school study can count toward the 7,500. |
| Exam | 100 questions, 4 hours, 70% to pass |
| Books allowed | 2018 IPC and IFGC, Mathematics for Plumbers and Pipefitters (8th edition), a backflow text and 29 CFR 1926 |
| Fees | $65 to PSI, plus Board application and license fees |
Plumbers applying for a Maryland journey plumber/gas fitter license from the State Board of Plumbing, after 4 years and 7,500 hours as a licensed apprentice (up to 1,500 hours of school credit).
Official links
How to get licensed, step by step
Confirm you qualify
4 years and at least 7,500 hours as a licensed apprentice plumber under a licensed master plumber; up to 1,500 hours of approved school study can count toward the 7,500.
Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)Maryland Code (General Assembly) (opens in a new tab)
Apply through PSI
Submit the exam application online at the PSI site below (mailed or faxed applications are returned). PSI and the Board review your documents, then email you how to pay and schedule.
Schedule with PSI (plumbers and gas fitters) (opens in a new tab)
Pass the open-book exam
Exam fees are non-refundable and non-transferable. The bulletin lists no waiting period between attempts; confirm with PSI.
Schedule with PSI (plumbers and gas fitters) (opens in a new tab)
Apply for the license
After you pass, the Board sends you the license application. Pay the license fee and file any required insurance.
Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)
How to prepare
- Tab your books before exam day: permanent plastic tabs (Avery Swift or Redi-Tag), highlighting and underlining are allowed; Post-It flags and writing in the book are not.
- Gas appliances and piping is 40 of the 100 questions: tab IFGC Chapters 3 to 7 and the pipe sizing tables, and practice sizing from the tables.
- Backflow prevention is 10 questions. Know the IPC Section 608 assembly requirements and any standard backflow text.
- No handheld calculator is allowed in the room, so practice the plumbing math by hand.
- The bulletin (8/10/2026) still lists the 2018 IPC and IFGC while the state code is now the 2024 edition; check the current bulletin before buying books.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 IPC and the 2018 IFGC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 International Plumbing Code (IPC)Essential
Allowed in the exam room. Drain, waste, vent, water supply and backflow questions.
2018 International Fuel Gas Code (IFGC)Essential
Allowed in the exam room. Gas appliances and piping are 40 of the 100 plumber questions.
Mathematics for Plumbers and Pipefitters, Lee Smith, 8th Edition (2013)
Allowed in the exam room. Offsets, pipe sizing and volume math for the 7 math questions.
29 CFR 1926 (OSHA Construction Standards), sections on your reference list
Trenching, scaffolds, fall protection and ladders. Print just the listed sections.
Official reference list (as published by the testing agency)
- International Plumbing Code (IPC), 2018 edition (allowed in the exam room)
- International Fuel Gas Code (IFGC), 2018 edition (allowed in the exam room)
- Mathematics for Plumbers and Pipefitters, Lee Smith, 8th Edition, 2013 (allowed in the exam room)
- Any standard backflow text (allowed in the exam room)
- 29 CFR Part 1926 (OSHA construction standards), with latest amendments, or the PSI selections (allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Plumbing Fundamentals and Safety | 8 | |
| Materials, Uses, and Specifications | 6 | |
| Traps, Interceptors, and Backwater Valves | 4 | |
| Plumbing Fixtures, Fixture Fittings, and Plumbing Appliances | 4 | |
| Water Supply Systems | 8 | |
| Backflow Prevention | 10 | |
| Drain, Waste, and Vent Systems | 13 | |
| Gas Appliances and Piping | 40 | |
| Plumbing Mathematics | 7 |
Exam day details
- Administered by PSI Services for the Maryland State Board of Plumbing.
- Fee: $65 to PSI per exam. Board application and license fees are separate.
- 100 questions in 4 hours; 70 correct (70%) to pass. The journey outline matches the master outline except fundamentals and safety is 8 questions and there is no special topics section.
- Edition note: The PSI bulletin (8/10/2026) lists the 2018 IPC and IFGC. The Maryland codes moved to the 2024 editions on November 24, 2025, and the Board has said PSI will remove questions to comply with the 2024 codes. Check the current bulletin before you buy books.
- Open book: you may bring only the listed references (none are provided), which you may index, highlight and underline but not write in. Study guides are not allowed.
- Handheld calculators are not allowed in the exam room. Plan to work the plumbing mathematics section by hand.
- PSI adds one to ten unscored experimental items, and the time spent on them counts against your exam time.
- The Board approves your experience first; every master applicant also needs an approved 32-hour backflow prevention device testing course.
- If a code and a trade reference disagree, the code, law or regulation overrides the other sources. State-specific law overrides national law.
Frequently asked questions
What's on the Maryland journey plumber exam?
100 questions: gas appliances and piping 40, drain, waste and vent systems 13, backflow prevention 10, plumbing fundamentals and safety 8, water supply systems 8, plumbing mathematics 7, materials 6, traps and backwater valves 4 and fixtures 4.
How is the journey exam different from the master exam?
It has 3 more fundamentals and safety questions and no special topics section; the other topics are weighted the same.
Which books can I bring?
The 2018 IPC and IFGC, Mathematics for Plumbers and Pipefitters (8th edition), any standard backflow text and 29 CFR Part 1926. Check the current bulletin for edition changes.
Free questions with answers
Show all 10 free questions and answers
A new natural gas piping system inside a commercial building will operate at a maximum working pressure of 5 psig. What is the minimum pressure to which the piping must be tested before it is accepted?
Answer: 7.5 psig
Section 406.4.1 requires a test pressure of at least 1-1/2 times the proposed maximum working pressure, and never less than 3 psig. 1.5 x 5 psig = 7.5 psig. Testing at the working pressure (5 psig) or at twice it (10 psig) is not what the code states.
Reference: 2018 International Fuel Gas Code, 406.4.1
A new gas piping system in a single-family dwelling has been filled with air for a pressure test. What is the minimum test duration?
Answer: 10 minutes
Section 406.4.2 sets the duration at 1/2 hour for each 500 cubic feet of pipe volume, but for a system under 10 cubic feet or a system in a single-family dwelling the minimum is 10 minutes. The 30-minute figure applies to larger volumes, not a house.
Reference: 2018 International Fuel Gas Code, 406.4.2
A horizontal 3-inch drain must be installed at the minimum slope allowed by Table 704.1 over a run of 60 feet. What total drop does the pipe need from one end to the other?
Answer: 7.5 inches
Table 704.1 gives a minimum slope of 1/8 inch per foot for 3- to 6-inch pipe. 60 ft x 1/8 in/ft = 7.5 inches of fall. Using 1/4 inch per foot (the 2-1/2 inch and smaller slope) would give 15 inches.
Reference: 2018 International Plumbing Code, Table 704.1
What liquid seal depth range is required for a fixture trap?
Answer: 2 inches to 4 inches
Section 1002.4 requires each fixture trap to have a liquid seal of not less than 2 inches and not more than 4 inches (deeper only for special designs for accessible fixtures).
Reference: 2018 International Plumbing Code, 1002.4
What is the least dimension and minimum interior area required for a shower compartment (general rule, no exceptions)?
Answer: 30 inches and 900 square inches
Section 421.4 requires a shower compartment of at least 900 square inches of interior cross-sectional area and at least 30 inches in least dimension, measured at the top of the threshold up to 70 inches above the drain, exclusive of valves and grab bars.
Reference: 2018 International Plumbing Code, 421.4
At which location is a full-open valve required on a water supply system?
Answer: On the discharge side of every water meter
Section 606.1 requires full-open valves on the building water service near the curb, at the entrance to the structure, on the discharge side of every water meter and at the base of certain risers. Fixture supplies and sillcocks are covered by shutoff valves in Section 606.2.
Reference: 2018 International Plumbing Code, 606.1, 606.2
A lavatory faucet has an effective opening of 1/2 inch or less, and the spout is away from any wall. What is the minimum air gap above the flood level rim?
Answer: 1 inch
Table 608.16.1 gives 1 inch away from a wall and 1-1/2 inches close to a wall for lavatories and other fixtures with effective openings not greater than 1/2 inch.
Reference: 2018 International Plumbing Code, Table 608.16.1
What is the minimum slope for a horizontal 2-inch drainage pipe?
Answer: 1/4 inch per foot
Table 704.1 requires 1/4 inch per foot for pipe 2-1/2 inches and smaller, 1/8 inch per foot for 3 to 6 inch pipe and 1/16 inch per foot for 8 inch and larger.
Reference: 2018 International Plumbing Code, Table 704.1
A copper water tube passes through a hole in a steel stud. What does the code require to prevent corrosion at the contact?
Answer: A sheath at least 8 mil thick, or other approved separation
Section 305.1 prohibits direct contact of metallic piping (except cast iron, ductile iron and galvanized steel) with steel framing, concrete, cinder walls or masonry. Where sheathing is used, it must be at least 0.008 inch (8 mil) thick.
Reference: 2018 International Plumbing Code, 305.1
Which of the following is a prohibited joint or connection in a water supply system?
Answer: A saddle-type fitting tapped into a water pipe
Section 605.9 prohibits cement or concrete joints, joints with fittings not approved for the installation, solvent-cement joints between different types of plastic pipe, and saddle-type fittings.
Reference: 2018 International Plumbing Code, 605.9
Sources
- PSI: Maryland Plumbing and Gas Fitter Examinations Candidate Information Bulletin (8/10/2026) (opens in a new tab)
- Maryland Department of Labor: Occupational and Professional Licensing (opens in a new tab)
- Maryland General Assembly: Maryland Code (statutes) (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.