Requirements at a glance
| Agency | City of Indianapolis / Marion County; exams by Prov |
|---|---|
| License | Air Conditioning "D": single phase, 5 tons cooling, 300,000 Btu/h heating input, boilers to 15 psig steam or 30 psig water |
| Exam | Air Conditioning "D": 80 questions, 3 hours, 70% |
| Books allowed | 2018 IMC, IRC, IFGC and IECC; ductulator; Pearson HVAC Basics and the Intermediate and Advanced Mechanical study guides |
| Eligibility | 5 years of heating and cooling experience, or school plus experience totaling 5 years (Revised Code 875-309); Board interview; EPA certification |
| Retakes | Prov: wait 30 days and get a new approval. Board policy: 60-69% may retest once without reappearing; after a second failure, wait one year |
| Fees | $100 to Prov; City license holder fee $189 to $377 depending on when you apply in the two-year term ($247 renewal) |
| Bond and insurance | $5,000 surety bond, $500,000 general liability naming the City, and workers' compensation (or a waiver if you have no employees) |
Heating and cooling contractors in Indianapolis and Marion County doing smaller systems. The "D" license covers single phase, up to 5 tons of cooling, up to 300,000 Btu/h heating input, and boilers up to 15 psig steam or 30 psig water.
Official links
- City of Indianapolis: contractor licenses (opens in a new tab)
- Revised Code of Indianapolis, Chapter 875 (contractor licensing) (opens in a new tab)
- Prov: Marion County (Indianapolis) bulletin (opens in a new tab)
- Schedule with Prov (opens in a new tab)
- Prov bookstore (exam reference books) (opens in a new tab)
How to get licensed, step by step
Apply to Indianapolis
Indiana has no statewide HVAC license; the Indianapolis Board of Heating and Cooling Examiners approves candidates. Send the exam application, a resume, employer letters verifying 5 years of experience, three industry reference letters, your EPA card and driver's license at least 10 business days before the Board's monthly meeting, then interview with the Board. Questions: (317) 327-8467.
City of Indianapolis: contractor licenses (opens in a new tab)
Schedule with Prov
Once approved, register and schedule at provexam.com, at one of Prov's 17 Indiana testing centers or remotely from home. Reschedule at least 3 days ahead or you lose the fee.
Schedule with Prov (opens in a new tab)Prov: Marion County (Indianapolis) bulletin (opens in a new tab)
Take the open-book exam
70% to pass. Prov scores it immediately and sends the result to Marion County. If you fail, wait 30 days and get a new approval before you retest.
Prov: Marion County (Indianapolis) bulletin (opens in a new tab)
Get licensed
After you pass, return to the Board for orientation, then send BNS the license application with your bond, insurance certificate, workers' compensation proof and fees. Licenses expire December 31 of odd-numbered years.
City of Indianapolis: contractor licenses (opens in a new tab)
How to prepare
- The Marion County exam uses the 2018 ICC codes, not Indiana's older state-adopted mechanical code. Bring the 2018 editions.
- The Pearson study guides, ACCA Manual J and N and the ductulator are all allowed. Tab the load calculation and duct sizing steps; sizing questions are 20 to 22 of the questions.
- Systems and sizing (22) and general knowledge (20) are more than half the exam. Know the license limits: 5 tons, 300,000 Btu/h, 15 psig steam, 30 psig water.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 IMC and the 2018 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Mechanical Code (IMC), 2018 EditionEssential
Allowed in the exam room. Ducts, ventilation, piping and equipment installation.
International Residential Code (IRC), 2018 EditionEssential
Allowed in the exam room for the Air Conditioning "D" exam.
International Fuel Gas Code (IFGC), 2018 Edition
Allowed in the exam room. Gas piping sizing and appliance venting.
HVAC Basics for Contractors, 3rd Edition (Pearson)
Allowed in the exam room. General knowledge, equipment and maintenance.
Official reference list (as published by the testing agency)
- International Residential Code, 2018 (open book)
- International Mechanical Code, 2018 (open book)
- International Fuel Gas Code, 2018 (open book)
- International Energy Conservation Code, 2018 (open book)
- HVAC Basics for Contractors, 3rd Edition, Pearson (open book)
- Intermediate Mechanical Study Guide, 2015, Pearson (open book)
- Advanced Mechanical Study Guide, 2nd Edition, Pearson (open book)
- Trane Ductulator, 2013 (the ACCA ductulator is also allowed; open book)
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 20 | |
| Piping | 12 | |
| Equipment | 10 | |
| Maintenance | 12 | |
| Plan Reading | 4 | |
| Systems & Sizing | 22 |
Exam day details
- Administered by Prov, Inc. for Marion County (Indianapolis).
- Fee: $100 to Prov. The Indianapolis license holder fee is separate ($189 to $377 depending on when you apply in the two-year term).
- 80 questions in 3 hours; 70% to pass.
- The Marion County exam uses the 2018 ICC codes, including the 2018 International Residential Code.
- Open book: bring the references the Prov bulletin lists as open book (codes, ACCA Manual J and N, the Trane or ACCA ductulator and the Pearson study guides).
- To be approved to test you need at least 5 years of practical heating and cooling experience, or a mix of school and experience totaling 5 years (Revised Code 875-309). Send the Board of Heating and Cooling Examiners the exam application, a resume, employer letters on letterhead verifying the 5 years, three reference letters from people in the HVACR industry, your EPA certification card and a copy of your driver's license at least 10 business days before its monthly meeting (second Monday). You then interview with the Board.
- Once approved, you schedule with Prov, at one of its 17 Indiana testing centers or remotely from home.
- Prov's bulletin says to wait 30 days after a fail and get a new approval before retesting. Under the Board's 2026 policy, a score of 60% to 69% allows one retest without going back before the Board; under 60% you must reappear with evidence you have improved; after a second failure you wait one year.
- Reschedule or cancel at least 3 days before your appointment, or you forfeit the exam fee.
- After you pass, you go back before the Board for orientation, then send the City a $5,000 surety bond, a general liability certificate ($500,000 per occurrence, naming the City as additional insured) and workers' compensation proof with the license application (Revised Code 875-315 and 875-316).
- City license holder fee (2026-2027 term): $377 if you apply January to June 2026, $283 July to December 2026, $189 in 2027; $247 to renew. A business license is also needed ($247 for a full term, prorated the same way; not charged to sole proprietors). Licenses expire December 31 of odd-numbered years.
- The Board requires EPA Type I and Type II certification for the "D" license.
Frequently asked questions
What's on the Indianapolis Air Conditioning "D" exam?
80 questions: systems and sizing 22, general knowledge 20, piping 12, maintenance 12, equipment 10 and plan reading 4.
What are the limits of the "D" license?
Single phase systems, 5 tons of cooling, 300,000 Btu/h of heating input, and boilers limited to 15 psig steam and 30 psig water.
Which books can I use on the "D" exam?
It is open book: the 2018 IMC, IRC, IFGC and IECC, the Pearson HVAC Basics, Intermediate and Advanced Mechanical study guides and the Trane or ACCA ductulator.
Free questions with answers
Show all 10 free questions and answers
What is the maximum cooling capacity that an Indianapolis (Marion County) Air Conditioning "D" license holder may install?
Answer: 5 tons
The "D" license is limited to single-phase systems with a five-ton cooling capacity and 300,000 Btu/h input heating capacity. Larger equipment falls under a higher class of air conditioning license.
Reference: Prov Marion County Candidate Information Bulletin (2026), 5.3 Air Conditioning "D" License
Under the longest length method, how is the pipe length determined for sizing each section of gas piping?
Answer: From the point of delivery to the most remote outlet, for every section
Section G2413.4.1 sizes each section using the longest length of piping from the point of delivery to the most remote outlet together with the load of that section.
Reference: 2018 International Residential Code, G2413.4.1
Which fitting is allowed in a concealed location in a gas piping system under Section G2415.5?
Answer: A threaded tee
Section G2415.5 limits concealed fittings to threaded elbows, tees and couplings, brazed fittings, welded fittings, and fittings listed to ANSI LC1 or LC4. Unions and slip joints are not on the list.
Reference: 2018 International Residential Code, G2415.5
A cooling coil is added in the supply plenum of an existing warm-air furnace that is not listed for use with a cooling coil. What blower rating does Section M1411.2 require?
Answer: Not less than 0.5 inch water column static pressure
Section M1411.2 says the furnace blower must be rated at not less than 0.5 inch w.c. unless the furnace is listed for use with a cooling coil. The coil may not sit upstream of the heat exchanger unless listed for it.
Reference: 2018 International Residential Code, M1411.2
A system moves 1,200 cfm with a 20 degree F air temperature difference across the coil. What sensible capacity is delivered using Q = 1.08 x cfm x delta-T?
Answer: 25,920 Btu/h
Q = 1.08 x 1,200 cfm x 20 F = 25,920 Btu/h. 24,000 comes from dropping the 1.08 factor and 21,600 from using 18 as the multiplier.
Reference: Standard HVAC load and airflow relationships (ACCA Manual J and ductulator practice), Q = 1.08 x cfm x delta-T
An 80,000 Btu/h natural gas furnace uses gas at 1,000 Btu per cubic foot. How many cubic feet per hour does it burn at full fire?
Answer: 80 cfh
Gas flow = input / heating value = 80,000 / 1,000 = 80 cfh. Dividing by 2,500 Btu per cubic foot, the typical LP figure, would give 32 cfh.
Reference: 2018 International Residential Code, G2413.2 and Table G2413.4(1) (cfh basis)
Which maintenance point applies to refrigerant circuit access ports located outdoors under Section M1411.8?
Answer: They must have locking tamper-resistant caps or be otherwise secured
Section M1411.8 requires outdoor refrigerant circuit access ports to be fitted with locking-type tamper-resistant caps or otherwise secured to prevent unauthorized access.
Reference: 2018 International Residential Code, M1411.8
A technician replaces a failed single-wall vent connector. What slope must the vent connector have under Section G2427.10.7?
Answer: Upward toward the vent at least 1/4 inch per foot
Section G2427.10.7 requires vent connectors to be installed without dips or sags and to slope upward toward the vent or chimney at least 1/4 inch per foot.
Reference: 2018 International Residential Code, G2427.10.7
A floor plan drawn at 1/4 inch = 1 foot shows a room measuring 5 inches on the drawing. What is the actual length?
Answer: 20 feet
At 1/4 inch per foot, each inch equals 4 feet, so 5 inches x 4 = 20 feet.
Reference: Standard HVAC drawing conventions, Architectural scale 1/4 in. = 1 ft
A 60,000 Btu/h furnace and a 40,000 Btu/h water heater share a closed room of 10 feet by 12 feet with an 8-foot ceiling. All combustion air is taken from the room. Does the room meet the standard method volume?
Answer: No; 960 cubic feet is provided but 5,000 cubic feet is required
Volume provided = 10 x 12 x 8 = 960 ft3. Required = 50 ft3 per 1,000 Btu/h x 100 = 5,000 ft3 (Section G2407.5.1). The room is far too small, so outdoor air must be provided under Section G2407.6 or another method.
Reference: 2018 International Residential Code, G2407.5.1
Sources
- Prov: Marion County Candidate Information Bulletin (air conditioning) (opens in a new tab)
- City of Indianapolis (Business and Neighborhood Services): contractor licenses (opens in a new tab)
- Revised Code of Indianapolis and Marion County, Chapter 875 (contractors and skilled trades) (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.